An experiment was conducted to study the effect of the sprayer type according to the source of power and the size of the spray nozzle concerning the quality of the spray produced and fuel consumption.Two types of sprayers were used: a conventional boom sprayer (S1) and a modified (electrified) boom sprayer (S2), along with three sizes of the XR TeeJet 110 spray nozzle (N). The following technical performance indicators were examined: Density of coverage (drops/cm2) using ImageJ software, a 600dpi business card scanner, specifically the ScanShell 800N by CSSN, Inc, and water-sensitive paper (WSP), rate of spray nozzles discharge (ml/min), and fuel consumption (liters/hectare) using a calibrated cylinder, and the percentage of weed control by sampling treated and untreated weeds. The experiment was designed as a complete randomized block design in the order of the system (Nested design). Sprayer type had significant effect on spray coverage and nozzle discharge rate. The conventional boom sprayer resulted in a coverage of 169.5 drops/cm2, while the modified (electrified) boom sprayer achieved only 149.4 drops/cm2. The discharge rate was 707.5 ml/min when using the conventional boom sprayer, compared to 671.2 ml/min with lower pesticide consumption when using the modified (electrified) boom sprayer.The smaller-sized XR TeeJet 110.015 VP nozzle (N1) outperformed the other nozzle sizes in terms of coverage (178.7 drops/cm2), weed control percentage (84.56%), and lower pesticide consumption (lower nozzle discharge) of 490.4 ml/min.
The performance of a diesel engine was tested with diesel oil contaminated with glycol at the engineering workshop/Department of Agricultural Machines and Equipment / College of the Agricultural Engineering Sciences at the University of Baghdad. To investigate the impact of different concentrations of glycol on the performance of a diesel engine, an experimental water-cooled four-stroke motor was utilized, with oil containing 0, 100, and 200 parts per million (ppm). Specific fuel consumption, thermal efficiency, friction power, and exhaust gas temperature were examined as performance indicators. To compare the significance of the treatments, the study employed a full randomization des
Abstract
This study aims at clarifying the current performance appraisal system in government units and the extent to which they contribute to the development of the performance of these units by evaluating and measuring the performance of these units on an ongoing basis to subject their services to an assessment and measurement process in order to improve the efficiency of these units to reach their objectives efficiently and effectively. (Iraqi hospitals) by trying to determine the possibility of the government accounting system in the process of evaluating performance, through the comparison of financial performance for successive years and different hospitals using the financial and non-financial model of the evaluati
... Show MoreField experiment conducted to measured Slippage, Effective field capacity, Field Efficiency, Soil Volume Disturbed and Specific Productivity Tillage in silt clay loam soil with depth 18 cm in Baghdad- Iraq. Split – split plot design under randomized complete block design with three replications using Least Significant Design 5 % was used. Three factor used in this experiment included Two types of plows included Chisel and Disk plows which represented main plot , Three Tires Inflation Pressure was second factor included 1.1 ,1.8 and 2.7 Bar, and Three forward speeds of the tillage was third factor included 2.35 , 4.25 and 6.50 km/hr. Result show chisel plow recorded best parameters performance
This work presents a five-period chaotic system called the Duffing system, in which the effect of changing the initial conditions and system parameters d, g and w, on the behavior of the chaotic system, is studied. This work provides a complete analysis of system properties such as time series, attractors, and Fast Fourier Transformation Spectrum (FFT). The system shows periodic behavior when the initial conditions xi and yi equal 0.8 and 0, respectively, then the system becomes quasi-chaotic when the initial conditions xi and yi equal 0 and 0, and when the system parameters d, g and w equal 0.02, 8 and 0.09. Finally, the system exhibits hyperchaotic behavior at the first two conditions, 0 and 0, and the bandwidth of the chaotic
... Show MoreIn IRAQ, the air conditioners are the principal cause of high electrical demand. In summer, the outer temperature sometimes exceeds 500C which significantly effects on the A/C system performance and power consumed. In the present work, the improvement in mechanical and electrical performance of split A/C system is investigated experimentally and analytically. In this paper, performance and energy saving enhancement of a split-A/C system was experimentally investigated to be efficiently compatible with elevated temperature weathers. This improvement is accomplished via Smart Control System integrate with Proportional-Integral- Differential PID algorithm. The PIC16F877A micro-controller has been programmed with the PID and PWM c
... Show MoreThe Local and Global Corporations are suffering of managerial and financial corruption phenomena, which leads them to loss and bankruptcy. So, it is necessary to search for tools which help prevent phenomena like this, and one of these tools is (corporate governance) which represent controlling tool that contribute in reducing corruption. this study aims at modifying (corporate governance system)in order to make it suitable with Iraqi government Corporations. the study depend upon main hypothesis which is (the performance level of the strategic perspective of governance system is depending upon work according to the perspective dimensions itself. From the main conclusions:-It is possible to building a strategic perspective
... Show MoreThe purpose of this study is to assess the performance of government units (Iraqi hospitals) by trying to determine the possibility of the current governmental accounting system to provide information on the performance reports of government units. In order to improve the efficiency of hospital resources management, the services provided by the hospital should be subject to performance measurement and evaluation The importance of the health sector in the provision of services, in order to raise the efficiency of the performance of services provided by government units has reached the researcher a set of conclusions, the most important
- The financial reports produced by the accounting s
We wanted to find out how selenium (Se) affects broiler chicken performance, meat physicochemical properties, and selenium deposition in the tissues of broilers. Each of the 96 experimental pens had 30 chickens and included a total of 2,880 one-day-old broilers (Cobb 500 strain). A factorial design of four-by-three (SY + SS) and eight replicates (SY + SS) was used for the 12 experimental treatments, with selenium levels ranging from 0.15 to 0.60 ppm and organic (SY) or inorganic (SS) sources of selenium and their relationship (SY + SS). There were no differences in performance (P > 0.05) across Se levels or sources. 106 g/day of ADFI, 63 g/day of ADG, and 1.6844 kg/kg of FCR were found to be the averaging values for these three parameters:
... Show MoreFor a long time, the intensification of profit represented a major goal for the company management ,but this goal confirmed a series of restrictions such the constriction on short period, the time rather than on long and medium strategic goal, the relationships with customers ,the supplies, employees , This goal is replaced by another one (intensification of the company's value) ,and the fortune of the share holders itself ,for the purpose of creating value, the company must generate great outcomes to cover the operating expense and to insure the a suitable compensation to the invested capital (the market value added) is the indication used to estimate the company ability to create value –added the development
... Show MoreExperimental tests were conducted to investigate the thermal performance (cooling effect) of water mist system consisting of 5μm volume median diameter droplets in reducing the heat gain entering a room through the roof and the west wall by reducing the outside surface temperature due to the evaporative cooling effect during the hot dry summer of Baghdad/Iraq. The test period
was Fifty one days during the months May, June, and July 2012. The single test day consists of 16 test hours starting from 8:00 am to 12:00 pm. The results showed a reduction range of 1.71 to 15.5℃ of the roof outside surface temperature and 21.3 to 76.6% reduction in the daily heat flux entering the room through the roof compared with the case of not using w