Amino acids are the basic building block for peptides and proteins. They are raw materials for generating hormones, purines, pyrimidines and vitamins. Amino acids also provide the body with energy through their carbon structures. The study analyzed the amino acid in the kidneys of the albino mice embryo at 17 and 19 gestation days, using a high-performance liquid chromatography device (HPLC). Samples were obtained after removing them from the embryo and placing them in an ice bath to prevent cell lysis and acid loss. The study found 18 amino acids in the kidneys of the albino mice embryo. They are Asparagine (Asn), Glutamine (Glu), Serine (Ser), Glycine (Gly), Threonine (Thr), Histidine (His), Cysteine (Cys), Alanine (Ala), Proline (Pro), Tryptophan (Tryp), Arginine (Arg), Tyrosine (Tyr), Valine (Val), Methionine (Met), Isoleucine (Ile), Leucine (Leu), Phenylalanine (Phe), and Lysine (Iys). Keywords: Amino acid, Mus musculus, Embryo, Kidney.
One of the most important challenges facing the designers of the sewerage system is the corrosion of sewers due to the influence of sewerage contaminates which lead to failure of the main lines of sewers. In this study, a reference mix of 1: 1.5: 3 was used and the 4% Flocrete PC200 by weight of cement was added to the same mixing ratio in the second mixture. Twenty-four samples were tested for each mixture, 12 of which were used to compression strength test in ages (7, 14 and 28) day and six samples were submerged after 28 days of wet treatment at (5 and 10) % concentrations of sulfuric acid. The other six samples were painted after 28 days of wet treatment with coating Polyurethane and after 24 hours were flooded with a concentrat
... Show MoreMefenamic acid belongs to non-steroidal anti-inflammatory drugs that are used widely for the treatment of analgesia. Our aim from this study is to establish a new assay for the quantitative determination of mefenamic acid (MFA) in the pharmaceutical sample by two sensitive and rapid flow injection-fluorometric methods. A homemade fluorometer was used in fluorescence measurements, which using solid-state laser diode 405 and 532 nm as a source, combined with a continuous flow injection technique. The first method depends on the effect of MFA on calcein blue (CLB) fluorescence at 405 nm. Another method is a study of rhodamine-6G (Rh-6G) fluorescence after adding MFA, and recording at 532 nm. Optimum parameters as fluorescent dye concen
... Show MoreIn this study a new ligand ,(potassium 2-carbomethoxy amino-5-trithiocarbonate 1,3,4-thiadiazole) (L) has been prepared from 2-carbomethoxy amino-5-mercapto 1,3,4-thiadiazole with CS2 in alkali media . The product has been isolated and characterized by appropriate physical measurements, vibrational and electronic spectroscopy. The ligand was used to prepare a number of complexes with some metal ions Co(II), Ni(II) and Cu(II). These complexes have been characterized by FT-IR, UV-Vis spectra, molar conductivity, magnetic susceptibility, melting points and atomic absorption measurements. The nickel and copper complexes have an octahedral geometry while cobalt complex has a tetrahedral geometry. The nature of bonding between the metal ion
... Show MoreThe process involved isolating E. faecium from the gut of honeybees, screening the bacterium for bacteriocin-like inhibitory substance (BLIS), evaluating its impact on the expression of the mexA gene in multidrug-resistant (MDR) P. aeruginosa, and determining the role of bacteriocin in treating infected wounds in mice through histopathological examination. After evaluating the best circumstances for producing BLIS, it was discovered that glucose was a superior carbon source and yeast extract was the best source of nitrogen. The pH was found to be 5, the ideal incubation time was 72 hours, and ammonium sulfate salt was used for partial purification at 80% saturation. The identification of MDR P. aeruginosa isolates from pus infection
... Show MoreA mercury porosimeter has been used to measure the intrusion volume of the three types mercury positive lead acid-battery plates. The intrusion volumes were used to calculate the pore diameter, pore volume, pore area, and pore size distribution. The variation of the pore area in positive lead acid-battery plates as well as of the pore volume has the following sequence. Paste positive > Uncured positive > Cured positive
Diabetic kidney disease (DKD) is caused by a variety of processes. As a result, one biomarker is insufficient to represent the complete process. This study Evaluate the diagnostic value of serum kidney injury molecule-1(KIM-1) and cystatin C (CysC) as early biochemical markers of DKD and predictive their sensitivities and specificities as biomarkers of nephropathy in Iraqi type 2 diabetic (T2DM) patients. This cross-sectional study include 161 T2DM patients from Diabetes and Endocrinology Center at Merjan medical city in Babylon. Patients divided according to urinary albumin creatinine ratio(ACR) (Group1:ACR≤30mg/g,Group2:ACR>30mg/g). Random spot urine and fasting blood samples were taken from each patient and urinary ACR, bloo
... Show More