The Humidification-Dehumidification (HDH) desalination technique offers a viable solution for providing freshwater to populations in water-scarce, remote areas. This study experimentally investigates a novel humidifying method by cross airflow over water-wetted pottery tubes, which function as a humidifier, incorporating a thermoelectric cooler to condense water vapor for freshwater production. To optimize freshwater production and thermal efficiency, meticulous design of these components and appropriate operational parameters are selected. Experiments were performed in three environments with differing temperatures and relative humidity levels, while air velocity varied from 1.02 to 1.89 m/s, and thermoelectric cooler voltage ranged from 6 to 12 V. These measures include GOR, COP, fresh water production, and dehumidifier efficiency. Air, saline water, and thermoelectric cooler voltage volume flow rates greatly affected system performance, according to the findings. The obtained optimal freshwater yield, COP, humidification efficiency, evaporation efficiency, and GOR were 1.7 L/hr, 4.3, 71 %, 65 %, and 4.6, respectively. Higher water productivity is indicated for low saline water flowrate supplied. Results show 71 % efficiency of the pottery tube humidifier for air speed lower than 1.02 m/s. Increasing the air flow rate from 38.88 m3/hr to 72 m3/hr decreases the system’s freshwater yield from 1.7 L/hr to 0.7 L/hr. A 55.8 % reduction in COP is found as the thermoelectric voltage increases from 6 to 12 volts for the same air flow rate (38 m3/hr). The results indicate that pottery tubes and air velocity significantly influence freshwater yield and energy efficiency, thereby promoting cost-effective and sustainable atmospheric water harvesting.
lar water heating systems with heat pipes of three diameter groups of 16, 22 and 28.5 mm. The first and third groups had evaporator lengths of 1150, 1300 and 1550 mm. The second group had an additional length of 1800 mm. all heat pipes were of fixed condenser length of 200 mm. Ethanol at 50% fill charge ratio of the evaporator volume was used as the heat pipes working fluid. Each heat pipe condenser section was inserted in a storage tank and the evaporator section inserted into an evacuated glass tube of the Owens- Illinois type. The combined heat pipe and evacuated glass tube form an active solar collector of a unique design.
The resulting ten solar water heating systems were tested outdoors under the meteorological conditions of Bag
Experimental work has been performed on three capillary tubes of different lengths and diameters using R-12 and R-134a. The test also studies the effect of discharge and speed of evaporator fan. The results clearly showed that refrigerant type and discharge significantly influence the temperature drop across the capillary tube. While the speed of evaporator fan has small effect. Experimental results showed that the temperature gradient for the two refrigerants are the same, but after approximatly one meter the temperature gradient of R-134a is steeper than R-12.
Introduction: Trichophyton indotineae has emerged globally as a highly contagious, terbinafine-resistant dermatophyte causing treatment-refractory superficial mycoses, posing a significant public health threat.This study evaluated the epidemiology of dermatophytosis in Babylon Province, Iraq, and performed molecular identification and phylogenetic analysis of local clinical isolates. Methods: Clinical specimens from 258 patients aged 1 to 71 years were analyzed. Following phenotypic characterization, genomic DNA was extracted from three representative isolates. Polymerase chain reaction amplified the internal transcribed spacer region, followed by DNA sequencing and neighbor-joining phylogenetic analysis. Results: Tinea corporis was
... Show MoreThe standard formulation of Wave Intensity Analysis (WIA) assumes that the flow velocity (U) in the conduit is <;<; the velocity of propagation of waves (c) in the system, and Mach number, M=U/c, is negligible. However, in the large conduit arteries, U is relatively high due to ventricular contraction and c is relatively low due to the large compliance; thus M is > 0, and may not be ignored. Therefore, the aim of this study is to identify experimentally the relationship between M and the reflection coefficient in vitro. Combinations of flexible tubes, of 2 m in length with isotropic and uniform circular cross sectional area along their longitudinal axes, were used to present mother and daughter tubes to produce a range of reflection coeffic
... Show MoreWater has been acknowledged as one of the key issues of humanity in modern society and worldwide economic advancements, especially with the continuing reductions in fresh-water supply. Solar energy, which is abundant as well as widely available in various fields, has the potential to solve the global challenges of long-term freshwater and energy reduction. Researchers are attempting to address the problem in a variety of methods. Due to the fact that solar energy is the foundation for freshwater, several researches have applied it for improving the effectiveness of solar desalination, evaporation, and wastewater treatment. One of the novel methods used for achieving this is known as “hydrogel,” which comes in a variety of forms. As a un
... Show MoreUsing zooplankton as bioindicators, this study evaluates the ecological condition of the Euphrates River in Iraq's Babylon Province. Site 1 (North Hillah, next to the old Babylon ruins), Site 2 (Hillah city center), Site 3 (South Hillah, close to Al-Mahaweel), and Site 4 (near Al-Kifl town) were the four monitoring locations chosen along the river. The highest and lowest averages of the measured physical and chemical factors indicate temperature (25.1°-29.4°), pH (7.2-7.9), electrical conductivity (EC) (940 µS/cm-1241µS/cm), total dissolved solids TDS (591 mg/L-789mg/L), dissolved oxygen (DO) (5.6 mg/ l-7.1 mg/L), biological oxygen demand (BOD5) (2.4mg/L-4.2 mg/L), nitrate (1.3 mg/L–3.2 mg/L), nitrite (0.04 mg/L–0.13 mg/L),
... Show MoreRotaviruses, a major cause of gastroenteritis in children worldwide accounts for around half a million deaths annually. Vaccine against the virus has been recommended by the WHO to be involved in the national immunization program.To evaluate the genetic characterization of rotavirus among children with acute gastroenteritis in Babylon province is warranted. Children complained of diarrhea with rotavirus infection detected in their stool were involved in the study. The age range was 10 months to 60 months and with retrogradechecking of rotavirus vaccine history. Rotavirus genotypes were detected by reverse transcription-polymerase chain reaction (RT-PCR).A total number of 40 children with rotavirus gastroenteritis were used to examine the
... Show More|
In this work, an experimental investigation has been done for heat transfer by natural-convection through a horizontal concentric annulus with porous media effects. The porous structure in gap spacing consists of a glass balls and replaced by plastic (PVC) balls with different sizes. The outer surface of outer tube is isothermally cooled while the outer surface of inner tube is heated with constant heat flux condition. The inner tube is heated with different supplied electrical power levels. Four different radius ratios of annulus are used. The effects of porous media material, particles size and annulus radius ratio on heat dissipation in terms of average Nusselt number have been analyzed. |
An experimental study was carried out for an evaporative cooling system in order to investigate the effect of using an aluminum pad coated with fabric polyester. In the present work, it was considered to use a new different type of cooling medium and test its performance during the change in the wet-bulb temperature and dry-bulb temperature of the supply air outside of the pad, the relative humidity of the supply air, the amount of air supplied (300-600) CFM and also the change of the amount of circulated water (1.75, 2.5, 4.5) liter per minute. A decrease in the WBT of the air was obtained, whereas the WBT of the air entering the pad was 26.5 . In contrast, the WBT of the outside air had reached 23 even though eva
... Show MoreExperimental study has been conducted for laminar natural convection heat transfer of air flow through a rectangular enclosure fitted with vertical partition. The partition was oriented parallel to the two vertical isothermal walls with different temperatures, while all the other surfaces of the enclosure were insulated. In this study a test rig has been designed and constructed to allow studying the effect of Rayleigh number, aperture height ratio, partition thickness, the position of aperture according to the side walls and according to the height, the position of the partition according to the hot wall, and partition inclination. The experiments were carried out with air as the working fluid for Rayleigh number range (5*107 – 1.3*10
... Show More