Researchers need to understand the differences between parametric and nonparametric regression models and how they work with available information about the relationship between response and explanatory variables and the distribution of random errors. This paper proposes a new nonparametric regression function for the kernel and employs it with the Nadaraya-Watson kernel estimator method and the Gaussian kernel function. The proposed kernel function (AMS) is then compared to the Gaussian kernel and the traditional parametric method, the ordinary least squares method (OLS). The objective of this study is to examine the effectiveness of nonparametric regression and identify the best-performing model when employing the Nadaraya-Watson kernel estimator method with the proposed kernel function (AMS), the Gaussian kernel, and the ordinary least squares (OLS) method. Additionally, it determines which method yields the most accurate results when analyzing nonparametric regression models and provides valuable insights for practitioners looking to apply these techniques in real-world scenarios. However, criteria such as generalized cross-validation (GCV), mean square error (MSE), and coefficient determination are used to select the most efficient estimated model. Simulated data was used to evaluate the performance and efficiency of estimators using different sample sizes. The results favorable the simulation illustrate that the Nadaraya-Watson kernel estimator using the proposed kernel function (AMS) exhibited favorable and superior performance compared to other methods. The coefficients of determination indicate that the highest values attained were 98%, 99%, and 99%. The proposed function (AMS) yielded the lowest MSE and GCV values across all samples. Therefore, this suggests that the model can generate precise predictions and enhance the performance of the focused data.
Effect of [Cu/In] ratio on the optical properties of CuInS2 thin films prepared by chemical spray pyrolysis on glass slides at 300oC was studied. The optical characteristics of the prepared thin films have been investigated using UV-VIS spectrophotometer in the wavelength range (300-1100 nm). The films have a direct allow electronic transition with optical energy gap (Eg) decreased from 1.51 eV to 1.30 eV with increasing of [Cu/In] ratio and as well as we notice that films have different behavior when annealed the films in the temperature 100oC (1h,2h), 200oC (1h,2h) for [Cu/In]=1.4 . Also the extinction coefficient (k), refractive index (n) and the real and imaginary dielectric constants (ε1, ε2) have been investigated
This study aimed to evaluate serum levels of steroid hormones and human chorionic gonadotropin (hCG) hormone in preeclamptic Iraqi pregnancies compared to those of healthy pregnancies.This study enrolled 120 pregnant women, divided into four groups:1. 30 healthy pregnant women.2. 37 pregnant women with mild preeclampsia3. 53 pregnant women with severe preeclampsia4. 90 pregnant women with preeclampsia Preeclamptic women and their severe cases but not mild cases had significantly (P<0.01) increased levels of serum hCG as compared with healthy pregnancies. By contrast, sera levels of estradiol were significantly (P<0.01) decreased in total preeclamptic groups and their severe cases but not in mild group as compared to healthy pregnant wome
... Show MoreWe wanted to find out how selenium (Se) affects broiler chicken performance, meat physicochemical properties, and selenium deposition in the tissues of broilers. Each of the 96 experimental pens had 30 chickens and included a total of 2,880 one-day-old broilers (Cobb 500 strain). A factorial design of four-by-three (SY + SS) and eight replicates (SY + SS) was used for the 12 experimental treatments, with selenium levels ranging from 0.15 to 0.60 ppm and organic (SY) or inorganic (SS) sources of selenium and their relationship (SY + SS). There were no differences in performance (P > 0.05) across Se levels or sources. 106 g/day of ADFI, 63 g/day of ADG, and 1.6844 kg/kg of FCR were found to be the averaging values for these three parameters:
... Show MoreMineral fillers are a fundamental component of asphalt mastic and play a critical role in governing the mechanical performance and durability of flexible pavements. Variations in filler type and dosage can substantially alter mastic stiffness, deformation resistance, fatigue behavior, and adhesion. The objective of this study is to systematically evaluate the influence of mineral filler type and filler-to-asphalt (F/A) ratio on the rheological, fatigue, and adhesive performance of asphalt mastics. Three commonly used fillers; limestone dust, Portland cement, and hydrated lime were investigated at four F/A ratios (0.6, 0.8, 1.0, and 1.2). A comprehensive experimental program was conducted, including conventional binder characterization, Mult
... Show MoreThe research problem is represented in the weakness of reliance on the role of some motor abilities (flexibility, balance and compatibility) in biomechanical indicators and the performance of a large number of gymnastics skills, including the skill of the human wheel, in addition to the lack of reliance on the use of video imaging of the skill in order to analyze its path and identify its weaknesses. The research aimed to identify the relationship between motor abilities, biomechanical indicators and the degree of performance of the skill of the human wheel, and the descriptive method was used on its own, chosen in an intentional method, consisting of (10) students from the third stage in the Department of Physical Education and Sp
... Show MoreGrowth is a multifactorial process influenced by genetic, nutritional, hormonal, psychosocial and other factors including the general health of a child. Epilepsy defined as a chronic condition characterized by recurrent clinical events or epileptic seizures, which occur in the absence of a metabolic or toxic disease the drugs that use in the treatment of this condition can affect patients growth due to their mechanisms of action. This study aimed to evaluate the effect of some antiepileptic drugs on growth (height and weight) in children with epilepsy. This work involved 51 newly diagnosed children with a different form of epilepsy (Generalized, absent and partial). Patients divided into three groups according to the treatment (group one
... Show MoreBackground/Aim: Endometrial abnormalities represent a diagnostic challenge due to overlapping imaging features with normal endometrium. Aim of this study was to assess accuracy of dynamic contrast-enhanced and diffusion-weighted magnetic resonance imaging (MRI) in evaluation of endometrial lesions in comparison with T2 and to assess local staging validity and degree of myometrial invasion in malignancy. Methods: Forty patients with abnormal vaginal bleeding or sonographic thickened endometrial were recruited. MRI examination of pelvis was per-formed using 1.5 T scanner with a pelvic array coil. Conventional T1-and T2, dynamic contrast-enhanced (DCE) sequences and diffusion-weighted image (DWI) were performed. Results: Mean age of pa
... Show MoreIn this work, oral lesions belong to 17 patients, 7 males and 10 females. Their ages range between 15 and 45 years. Follow up was conducted after one day, 7 days, 14 days, one month, and finally 3 months postoperatively. The study lasted for 1.5 year. Surgical diode laser with wavelength of 810 ± 20 nm, with two power levels of 10 and 15 W were used in contact and in non-contact mode via optical fiber. The postoperative outcome revealed; greater haemostatic capability, dry, sealed wound and noticeable lack in pain sensation
In this study, the optical and thermal performance of a Parabolic Trough Collector PTC system is investigated theoretically. A series of numerical simulations and theoretical analysis has been conducted to investigate the effect of the receiver geometry and location relative to the focal line on its optical performance. The examined receiver geometries are circular, square, triangular, elliptical and a new design of circular‐ square named as channel receiver. The thermal performance of PTC is studied for different flow rates from (0.27 to 0.6 lpm) theoretically. Results showed that the best optical design is the channel receiver with an optical efficiency of 84% while the worst is the elliptical