Background: Atrial fibrillation (AF) is a common arrhythmia in daily practice and one of the heart disorders with the highest morbidity and death rates, as it is responsible for a huge number of negative consequences. In our country, there is limited information on the prevalence or natural history of the less well-defined clinical types. Objective: to evaluate the clinical profile and coronary artery findings in atrial fibrillation patients. Patients and Methods: This cross-sectional study was conducted during the period from the first of October 2019 to end of July 2021 at the Iraqi Center for the heart disease at Baghdad Medical City. Included 32 Iraqi patients with atrial fibrillation of both genders. Angiography performed through the femoral Artery approach, Data collected by history, through clinical examination and investigations, using data collection sheet Results: The main type of AF was chronic, (62.5%), Echocardiography findings revealed Systolic dysfunction in 31.1% of patients, Diastolic dysfunction in 37.5%, and both dysfunctions in 6.2%, Left atrium was dilated in 13 (40.6%). Angiographic findings revealed RCA lesion in 13 (40.6%) patients, LCA in 9 (28.1%) while both RCA and LCA lesions present in 3 (9.4%) patients. LAD lesions reported in 10 (31.2%) patients, LCX in 27.8% and LMS in 16.8%. Conclusion: Chronic AF was the more frequent type, Systolic and diastolic dysfunction are frequent among AF patients. RCA was more frequently affected than LCA, LAD was the more affected branch.
The aim of this work was to capture solar radiation and convert it into solar thermal energy by using a storage material and the heat transfer fluid like oil and water and comparison between them, we used the evacuated tube as a receiver for solar radiation, The results showed that the oil better than water as storage material and the heat transfer fluid and the effective thermal conductivity material and good for power level, rates and durations of charge and discharge cycles.
In this work, the effect of aluminum (Al) dust particles on the DC discharge plasma properties in argon was investigated. A magnetron is placed behind the cathode at different pressures and with varying amounts of Al. The plasma temperature (Te) and density (ne) were calculated using the Boltzmann equation and Stark broadening phenomena, which are considered the most important plasma variables through which the other plasma parameters were calculated. The measurements showed that the emission intensity decreases with increasing pressure from 0.06 to 0.4 Torr, and it slightly decreases with the addition of the NPs. The calculations showed that the ne increased and Te decreased with pressure. Both Te and ne were reduced by increasing
... Show MoreBackground: Although various imaging modalities are available for evaluating suspicious breast lesions, ultrasound-based Shear-Wave Elastography (SWE) is an advanced, non-invasive technique complementary to grayscale sonography. This technique evaluates the elasticity of a specific tissue by applying sonic pressure to that tissue.
Objective: The aim is to assess the role of SWE in evaluating solid breast masses in correlation to histopathological study results.
Subjects and Methods: This prospective study was done in a tertiary care teaching hospital from September 2019 to August 2020. A study population of 50 women aged 18 years or above with an
... Show MoreThe prediction process of time series for some time-related phenomena, in particular, the autoregressive integrated moving average(ARIMA) models is one of the important topics in the theory of time series analysis in the applied statistics. Perhaps its importance lies in the basic stages in analyzing of the structure or modeling and the conditions that must be provided in the stochastic process. This paper deals with two methods of predicting the first was a special case of autoregressive integrated moving average which is ARIMA (0,1,1) if the value of the parameter equal to zero, then it is called Random Walk model, the second was the exponential weighted moving average (EWMA). It was implemented in the data of the monthly traff
... Show MoreAbstract Background: The hip joint and lumbar spine are both anatomically and functionally closely related as had shown by many authors. So the abnormality in one area can affect the other e.g. hip joint osteoarthritis can cause lumbar sagittal malalignment and backache. Objectives: is to see if there is significant improvement in backache after total hip replacement? And which degree of backache improvement is associated with significant changes in lumbar lordosis? Methods and patients: a prospective open trial study was performed on 30 patients who had severe hip osteoarthritis and chronic low back pain. Total hip replacement was performed to all patients. Backache and lumbar lordosis were measured by visual analogue scale and Cobb’s a
... Show More
