Preferred Language
Articles
/
pxf_LZIBVTCNdQwCw6fp
Poly-Ether-Ether-Ketone versus dead-soft coaxial bonded retainers: a randomized clinical trial. Part 2: periodontal health and microbial biofilm assessment
...Show More Authors
Abstract<sec> <title>Background

Retainers have the potential to detrimentally impact periodontal health and contribute to tooth decay.

Objectives

To investigate periodontal health and bacterial biofilm related to Poly-Ether-Ether-Ketone (PEEK) fixed retainers as compared to Dead-soft coaxial fixed retainer (DSC).

Trial design

A two-arm parallel groups single-centre randomized clinical trial.

Methods

The trial included patients whose orthodontic treatment was completed and required retainers. Participants were randomly assigned into two retainer groups: PEEK retainers, prepared by computer-aided design and manufacturing into 0.8 mm wire form, and DSC retainers. The objectives included assessing periodontal health through plaque accumulation index (PI), bleeding on probing (BOP), periodontal pocket depth (PPD), gingival index (GI), calculus index (CI), and alveolar bone height (ABH) assessment. Biofilm assessment involved bacteriological screening of aerobic, facultative anaerobic, mutans streptococci, and lactobacilli. The periodontal indices and microbiological screening as well as were assessed at the debonding stage (T0), 1-month (T1), 3-month (T3), and 6-month (T6) after the commencement of the trial, except for the ABH, which was recorded using periapical radiograph at T0 and T6.

Blinding

Single blinding of participants in addition to the bacteriological specialist.

Results

Initially, the trial enrolled 46 participants, aged between 12 and 28 years, and were randomly assigned to two groups, with 23 participants in each group. Subsequently, one participant withdrew from the trial, resulting in a total of 45 participants whose data were analysed. Assessment of the periodontal indices, excluding the CI (P = .480), revealed statistically but not clinically significant differences between groups after 6-month of retention (P = .016 of PI, P = .020 of BOP, P = .05 of PPD, and P = .01 of GI). There was slight plaque accumulation, normal PPD (approximately 1 mm), healthy to mild gingivitis with a GI of less than 1 and BOP was around 10%. Concerning the ABH, there was a noticeable reduction in its score after 6 months, particularly in the PEEK group, although the difference was not statistically significant (P = .102). Furthermore, the bacteriological viable count did not show any significant difference between the groups during the recall visits.

Harms

There have been no reported negative consequences.

Limitations

Blinding the assessor of periodontal indices was not feasible due to the nature of the intervention. The trial follow-up duration was limited.

Conclusions

Both the PEEK and DSC retainers have comparable impacts on periodontal health and bacterial accumulation and composition during the retention period.

Trial registration

NCT05557136.

Scopus Clarivate Crossref
View Publication
Publication Date
Sun Jan 01 2023
Journal Name
Aip Conference Proceedings
Comparison among variable selection models and its application to health dataset
...Show More Authors

View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sat Sep 12 2020
Journal Name
Al-kindy College Medical Journal
Antenatal, Intrapartum, and Postnatal Maternal health Care during COVID-19 Pandemic
...Show More Authors

There is limited data and evidence about the effects of COVID-19 on Maternal health, especially when new information is emerging daily, through pregnancy, child birth and post natal period, women are vulnerable to have the infection, this article, aimed to show the suitable measures that should be applied for women at reproductive age who are suspected /confirmed with COVID -19 infection,

During pregnancy it is advisable to continue the antenatal care schedule, although reducing face to face visit is recommended (unless the pregnant condition required that ),and prioritize ANC at health facilities for high-risk pregnancy and during second half of pregnancy with adequate infection prevention control  measures.

Regardi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 30 2015
Journal Name
Al-kindy College Medical Journal
Organizational and behavioral determinants of health information system performance in Iraq
...Show More Authors

Background: Health information systems in most countries are inadequate in providing the needed management support and the current health information systems are therefore widely seen as management obstacles rather than as tools,Objectives: the current study is an attempt to assess the behavioral and organizational determinants of health information system performance in Iraq.Methods: A cross-sectional study was conducted by interviewed a total of 189 respondents selected from six Iraqi governorates. The Organizational and Behavioral Assessment Tool was used to measure the behavioral and organizational determinants of health information system performance, it is one of the PRISM package tools that are used to assess the health informatio

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 30 2017
Journal Name
Journal Of Engineering
Study the effect of microbial factor on the qualities and characteristics of Novolak composite material, reinforced glass fibers / Asbestos fibers.
...Show More Authors

The study was reflection of the impact of the widespread use of polymer Novolak composite reinforced  Glass fiber and Asbestos fiber once again with weight fraction 60% on the physical properties, which included (Hardness, Compressive deformation, compressive modulus of elasticity, Flexural modulus of elasticity, Resilience modulus, the maximum of Flexural strength, Flexural strain energy and Shear strength inner layers); it is known how much important the media as a source of bacterial contamination, which contributes directly or indirectly in the process of aging of these materials. These Novolak composite reinforced,  prepared by weight fraction of (10%) and (14%) of the Hexamethylene-tetraamine (HMTA) hardener material. It

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Designing and Application of Mathematical Model A Multi – Objectives for Assessment The Quality Of The Project : A Case Study at Saad Public Construction Company
...Show More Authors

Abstract

This research aims to design a multi-objective mathematical model to assess the project quality based on three criteria: time, cost and performance. This model has been applied in one of the major projects formations of the Saad Public Company which enables to completion the project on time at an additional cost that would be within the estimated budget with a satisfactory level of the performance which match with consumer requirements. The problem of research is to ensure that the project is completed with the required quality Is subject to constraints, such as time, cost and performance, so this requires prioritizing multiple goals. The project

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Oral Medicine And Oral Surgery
Evaluating dental implant stability using three devices Osstell<sup>®</sup>, Periotest<sup>®</sup>, and AnyCheck<sup>®</sup>: a clinical study
...Show More Authors

Introduction: Implant stability is usually measured with resonance frequency analysis (RFA) and damping capacity assessment (DCA). This study aimed to measure primary and secondary stabilities using 3 devices that are based on these methods, namely; RFA (Osstell®) and DCA (Periotest® and AnyCheck®) to assess the correlations of the measurements obtained by these devices and the correlations between implant stability and insertion torque. Material and Methods: This observational prospective study included 35 dental implants. The implant stability was measured using the 3 devices. Mann–Whitney U

... Show More
View Publication
Scopus (2)
Crossref (4)
Scopus Crossref
Publication Date
Tue Feb 04 2014
Journal Name
Al-mustansiriyah
Synthesis, Spectroscopic and Biological Studies of some Metal Complexes with 2, 4-dinitro-2-amino hydrozo benzene.
...Show More Authors

Publication Date
Tue Mar 01 2016
Journal Name
Oriental Journal Of Chemistry
Synthesis and antioxidant ability of new 5-amino-1, 2, 4-triazole derivatives containing 2, 6-dimethoxyphenol
...Show More Authors

4-amino-3-(4-(((4-hydroxy-3, 5dimethoxybenzyl) oxy) methyl) phenyl)-1, 2, 4-triazole-5-thione was synthesized by to method the first one from melt reaction of 4-(((4-hydroxy-3, 5-dimethoxybenzyl) oxy) methyl) benzoic acid with Thiocarbonyldihydrazide, the second method from convert the corresponded acid hydrazide to potassium 2-(4-(((4-hydroxy-3, 5-dimethoxybenzyl) oxy) methyl) benzoyl) hydrazinecarbodithioate salt then react with hydrazine hydrate. Newly Schiff base (7a-7f) were synthesized from reaction the 4-amino-1, 2, 4-triazol with substituted hydroxybenzaldehyde. The resulting compounds were characterized by IR, 1H-NMR, 13C-NMR, and HRMS data. 2, 2-Diphenyl-1-picrylhydrazide (DPPH) and ferric reducing antioxidant power (FRAP) assays

... Show More
Publication Date
Mon Jun 08 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of different palatal vault shapes and woven glass fiber reinforcement on dimensional stability of high impact acrylic denture base [part II]
...Show More Authors

Background: Change in palatal vault shape and Reinforcement of high impact acrylic denture base resin may in turn affect the dimensional accuracy of acrylic resin and affecting the fitness of the denture. The aim of study is to evaluate the effect of fiber reinforcement for high-impact acrylic resin denture base with different palatal vault shapes on linear dimensional change and effect of palatal vault shapes on linear dimensional changes of non-reinforced and fiber reinforced high impact denture base acrylic resin Material and method: Three different palatal vault shapes were prepared on standard casts using CNC (computer numerical control) machine. 60 samples of heat polymerized high impact acrylic resin maxillary denture base were fabri

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 08 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of different palatal vault shapes and woven glass fiber reinforcement on dimensional stability of high impact acrylic denture base [Part I]
...Show More Authors

Background: Change in palatal vault shape and Reinforcement of high impact acrylic denture base resin may in turn affect the dimensional accuracy of acrylic resin and affecting the fitness of the denture.This study evaluated tostudy the effect of fiber reinforcement for high-impact acrylic resin denture base with different palatal vault shapes on adaptation or gap space between the denture base and the stone cast and compare with non-fiber reinforcement and effect of palatal vault shapes on adaptation of non-reinforced and fiber reinforced high impact denture base acrylic resin Material and method: Three different palatal vault shapes were prepared on standard casts using CNC (computer numerical control) machine. 60 samples of heat polymeri

... Show More
View Publication Preview PDF