Can the automated pump be an alternative to tourniquet in knee arthroscopy ?
...Show More Authors

ABSTRACT: BACKGROUND: Arthroscopic knee surgeries are performed in very large numbers worldwide, and in spite of relatively low complication rate, but the total number is significant. Some of these complications are due to tourniquet use and can be serious. OBJECTIVE: Is to asses if automated pump (with or without) dilute epinephrine saline irrigation can replace the tourniquet use in soft tissue arthroscopic knee surgeries. PATIENTS AND METHODS: 36 patients (9 females 25 % and 27 males 75 %) were included in this prospective experimental nonrandomized study, and were necessitated soft tissue arthroscopic knee surgeries. Patients were divided into two groups, in group A (patients) tourniquet and automated pump were used. In group B (18 patients) automated pump with or without epinephrine irrigation fluid were used. For both groups, visibility, time of surgery, amount of irrigation fluid used, pressure of pump, postoperative pain and hemoglobin level before and after surgery were assessed and compared. RESULTS: There was no significant statistical difference( p value more than 0.05) in regard to visibility, time of surgery, amount of irrigation fluid used, pressure of pump and postoperative pain between the two groups. There was no significant statistical difference between hemoglobin levels before and after surgery in both groups. CONCLUSION: Automated pump (with or without) dilute epinephrine saline irrigation can replace the tourniquet in soft tissue arthroscopic knee surgeries. KEY WORDS: arthroscopy , knee, pump, torniqute, epinephrine.

Preview PDF
Quick Preview PDF
Publication Date
Wed Jun 30 2010
Journal Name
Al-kindy College Medical Journal
Electrical stimulation for the treatment of Knee joint osteoarthritis
...Show More Authors

Abstract 20 patients with osteoarthritis of the knee joint were treated by electrical stimulation in the form of 6 sessions every other day each sessions of diphase fixe (DF) for 4 minutes followed by rest for 4 minutes then treated with a monophase fixe (MF) for 2 minutes. By clinical & statistical analysis ( P value < 0.05) we conclude that the electrical stimulation is effective as one method in the treatment of osteoarthritis.

View Publication Preview PDF
Publication Date
Mon Sep 30 2024
Journal Name
Open Veterinary Journal
Crude aqueous Proteus mirabilis extract with quorum sensing inhibitory activity can increase the susceptibility of multidrug resistant Pseudomonas aeruginosa to antimicrobials
...Show More Authors

Background: Suppression of quorum sensing (QS) that regulates many virulence factors, including antimicrobial resistance, in bacteria may subject the pathogenic microbes to the harmful consequences of the antibiotics, increasing their susceptibility to such drugs. Aim: The current study aimed to make an aqueous crude extract from the soil Proteus mirabilis isolate with the use of the gas chromatography-mass spectrometry (GC-MS) technique for its analysis, and then, study the impact of the extract on clinical isolates of Pseudomonas aeruginosa. Methods: Preparation of crude extracts from P. mirabilis (both organic and aqueous), which were then analyzed by GC-MS to detect the bioactive ingredients. Furthermore, the extract’s capability to i

... Show More
Preview PDF
Scopus Clarivate Crossref
Publication Date
Sun Mar 01 2015
Journal Name
Baghdad Science Journal
Studying the x- ray atomic Scattering form Factor and Nuclear Magnetic Shielding Constant for Be atom in its Excited state (1s2 2s 3s) and the Be - like ions
...Show More Authors

The division partitioning technique has been used to analyze the four electron systems into six-pairs electronic wave functions for ( for the Beryllium atom in its excited state (1s2 2s 3s ) and like ions ( B+1 ,C+2 ) using Hartree-Fock wave functions . The aim of this work is to study atomic scattering form factor f(s) for and nuclear magnetic shielding constant. The results are obtained numerically by using the computer software (Mathcad).

View Publication Preview PDF
Crossref
Publication Date
Thu Dec 31 2015
Journal Name
Al-khwarizmi Engineering Journal
Design and Construction of Electrical Magnate to Study its Efficiency and the Optimum Parameters to Produce Alkaline Magnetic Water and Treating the Sea Water to be Suitable for Irrigation
...Show More Authors

Abstract

Electrical magnate  was designed and constructed,  the optimum Magnetic flux  and the effect of time on the physical properties of the alkaline (magnetic water) produced from the bottled drinking water [the total dissolved solids (TDS) or the electrical conductivity, and pH] were studied, to simulate ZamZam water in Mekka Saudi Arabia. Also, the efficiency of magnetic field from this designed electrical magnate in decreasing the TDS of sea water (of 1500 ppm NaCl Content), to convert it to water suitable for irrigation (TDS<1000 ppm) was investigated in this work.The results show that the magnetic flux from our designed electrical magnate in the range of (0.013- 0.08) Tesla and 30 minut

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 30 2012
Journal Name
Al-kindy College Medical Journal
Age Influence on Knee Joint Flexors
...Show More Authors

Background : Knee flexors tightness has been documented in apparently healthy adults and in those with musculoskeletal problems, but the influence of age on the tightness has not been studied in Iraq. This study was therefore designed to determine the influence of age on knee flexors tightness in apparently healthy subjects.Methods: Knee flexors tightness was measured using the active knee extension test (AKET) in 200 apparently healthy male and female subjects, aged 13 to 59 years. The subjects were recruited into 5 age groups using the purposive sampling technique.Knee flexors tightness was compared across the age groups using one-way analysis ofvariance (ANOVA). The independent t-test was used to compare knee flexors tightness on both

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 02 2025
Journal Name
Engineering, Technology &amp; Applied Science Research
Automated Glaucoma Detection Techniques: A Literature Review
...Show More Authors

Significant advances in the automated glaucoma detection techniques have been made through the employment of the Machine Learning (ML) and Deep Learning (DL) methods, an overview of which will be provided in this paper. What sets the current literature review apart is its exclusive focus on the aforementioned techniques for glaucoma detection using the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines for filtering the selected papers. To achieve this, an advanced search was conducted in the Scopus database, specifically looking for research papers published in 2023, with the keywords "glaucoma detection", "machine learning", and "deep learning". Among the multiple found papers, the ones focusing

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Wed Jun 10 2009
Journal Name
Iraqi Journal Of Laser
Characteristic of Discrete Raman Amplifier at Different Pump Configurations
...Show More Authors

Discrete Raman amplifier have many attractive aspects over rare-earth doped fiber amplifier such as (EDFA) including arbitrary gain band, better adjustability of gain shape, and better linearity. This paper shows that discrete Raman amplifier has higher gain in bidirectional pumping than counter pumping. The gain increases with increasing fiber length, and the noise figure remain at the same value for short fiber length.

View Publication Preview PDF
Publication Date
Fri Jan 01 2016
Journal Name
International Archives Of Medicine
The role of MRI in the diagnosis of intra articular knee derangement: A prospective study
...Show More Authors

View Publication Preview PDF
Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Journal Of The College Of Education For Women
The influence of Ali (may Allah be pleased with him) on interpretation: The influence of Ali (may Allah be pleased with him) on interpretation
...Show More Authors

Abstract:
Through the research, I have briefly discussed the life of Imam Ali and
indicated the interpretation of the Qur'an by language and terminology, the
importance and characteristics of Sahabas', may Allah be pleased with them,
interpretation of the Qur'an. Also, the sayings of Imam Ali, wich included the
explanatory interpretation of the Qur'an by the Qura'n, Sunnah, language, and
correct opinion. I have also indicated the reasons of the Quran's revelation
and the readings of the Qura'n that had been received from him including the
interpretive meaning these readings revealed. Finally, I concluded my
research with the most important results and recommends.

View Publication Preview PDF
Publication Date
Thu Jun 08 2023
Journal Name
Iraqi Journal Of Laser
PDF Lab-On-a-Chip an integrated microfluidic device sensitive low-Cost, and Rapid with a syringe pump for Analysis of Ibuprofen
...Show More Authors

Abstract: Microfluidic devices present unique advantages for the development of efficient drug assay and screening. The microfluidic platforms might offer a more rapid and cost-effective alternative. Fluids are confined in devices that have a significant dimension on the micrometer scale. Due to this extreme confinement, the volumes used for drug assays are tiny (milliliters to femtoliters).

 In this research, a microfluidic chip consists of micro-channels carved on substrate materials built by using Acrylic (Polymethyl Methacrylate, PMMA) chip was designed using a Carbon Dioxide (CO2) laser machine. The CO2 parameters have influence on the width, depth, roughness of the chip. In order to have regular

... Show More