Preferred Language
Articles
/
pRY_S4oBVTCNdQwClJME
Fast and versatile ambient surface analysis by plasmaassisted desorption/ionisation mass spectrometry
...Show More Authors

has experienced a step-change since the inception of ambient mass spectrometry removed the requirement for samples to be investigated under vacuum conditions. Approaches based on surface– plasma interactions are especially promising, including PADI. Whilst the mechanisms involved in generating PADI spectra still need to be unravelled, PADI shows significant promise to become a valuable and versatile tool in the instrumental arsenal available to the surface analyst

Publication Date
Sun Sep 21 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of dental implant stability during healing period and determination of the factors that affect implant stability by means of resonance frequency analysis(Clinical study)
...Show More Authors

Background: Implant stability is considered one of the most important factors affecting healing and successful osseointegration of dental implants. The aims of the study were to measure the implant stability quotient (ISQ) values during the healing period and to determine the factors that affect implant stability. Materials and methods: Thirty patients enrolled in the study (17 female, 13 male). They received 44 Implantium® Dental Implants located as the following: 22 implants in maxillary jaw, 22 implants in mandibular jaw from them 17 implants in anterior segment and 27 in posterior segment. The bone density determined using interactive CT scan and classified according to the Misch bone density classification (29 implants in (D3), 15 i

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 01 2016
Journal Name
Journal Of Economics And Administrative Sciences
The role of practices by the Managing of human resources on effectiveness of organizational crisis Management Described and analysis research for ministry of Iraqi interior
...Show More Authors

The practice by the  administration of human resources  on effectiveness of organization  crisis as two knowledge fields , it were be until now as center for many studies, but the collect it, study of relation between them ,and The role of practices  by the  administration of human resources  on effectiveness of organization  crisis administration  were considered a new study and first according to the available and showing  studies at this field .

The problem of this research was specified by answer for the question that deal for size of consciousness at the ministry of interior for import of&nbs

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Journal Of Physics: Conference Series
The combined effectiveness of magnetic force and heat\mass transfer on peristaltic transportation “Hyperbolic Tangent” Nanofluid in a Slopping Non-Regular Non-symmetric Channel.
...Show More Authors
Abstract<p>in the present article, we present the peristaltic motion of “Hyperbolic Tangent nanofluid” by a porous area in a two dimensional non-regular a symmetric channel with an inclination under the impact of inclination angle under the impact of inclined magnetic force, the convection conditions of “heat and mass transfer” will be showed. The matter of the paper will be further simplified with the assumptions of long wave length and less “Reynolds number”. we are solved the coupled non-linear equations by using technical analysis of “Regular perturbation method” of series solutions. We are worked out the basic equations of continuity, motion, temperature, and volume fraction</p> ... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Sat Aug 31 2019
Journal Name
Iraqi Journal Of Physics
Manufacturing Zener diode using ZnO-CuO-ZnO/Si structures deposited laser induced plasma technique
...Show More Authors

        In this paper Zener diode was manufactured using ZnO-CuO-ZnO/Si heterojunction structure that used laser induced plasma technique to prepare the nanofilms. Six samples were prepared with a different number of laser pulses, started with 200 to 600 pulses on ZnO tablet with fixed the number of laser pulses on CuO tablet at 300 pulses. The pulse energy of laser deposited was 900mJ using ZnO tablet and 600mJ using CuO tablet. All prepared films shown good behavior as Zener diode when using porous silicon as substrate.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Dec 02 2018
Journal Name
Iraqi Journal Of Physics
Optical emission spectroscopy for studying the exploding copper wire plasma parameters in distilled water
...Show More Authors

This work aims to study the exploding copper wire plasma parameters by optical emission spectroscopy. The emission spectra of the copper plasma have been recorded and analyzed The plasma electron temperature (Te), was calculated by Boltzmann plot, and the electron density (ne) calculated by using Stark broadening method for different copper wire diameter (0.18, 0.24 and 0.3 mm) and current
of 75A in distilled water. The hydrogen (Hα line) 656.279 nm was used to calculate the electron density for different wire diameters by Stark broadening. It was found that the electron density ne decrease from 22.4×1016 cm-3 to 17×1016 cm-3 with increasing wire diameter from 0.18 mm to 0.3 mm while the electron temperatures increase from 0.741 to

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
The Effect of Grain Size-Secondary Electron Emission on Grain Growth in Dusty Plasma
...Show More Authors

The calculation of the charge on an isolated dust grain immersed in plasma with different grain sizes is a challenging one, especially under moderately high plasma temperature when secondary electron emission significant. The discrete charging model is used to calculate the charges of dust grain in dusty plasma. In this model, we included the effect of grain size dependence on secondary electron emission. The results show that the secondary electron emission from the glass dust grains due to energetic electron (40eV) can lead to the small grain to be slightly more positive than the large grain. Under these conditions, the smaller and larger grains would be attracted rather than repelled, which possibly lead to enhanced coagulation rates.

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Spectroscopic measurements of the electron temperature in low pressure microwave 2.45 GHz argon plasma
...Show More Authors

The main goal of this work is to obtain the plasma electron temperature Te by optical emission spectroscopy of low pressure microwave argon plasma, as a function of working pressure and microwave power. A plasma system was designed and constructed in our laboratory using a magnetron of domestic microwave oven with power 800W without any commercial part. The applied voltage on the magnetron electrical circuit is changed for the purpose of obtaining the variable values of the microwave power. The spectral detection is performed with a spectrometer of wavelength range (200−1000nm). The working pressure and magnetron applied voltage were 0.3-3.0mbar and 180-240V, respectively. Two methods had been applied to estimate the electron temperatu

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Jan 04 2020
Journal Name
Nternational Journal Of Plasma Environmental Science And Technology (ijpest)
Use of cold plasma in the synthesis of gold nanomaterials for parasitic leishmaniasis treatment
...Show More Authors

The atmospheric air cold plasma has been used to manufacture gold nanomaterials for treating parasitic leishmaniasis. This study experimentally assessed the treatment of Leishmania parasites (L. donovani and L. tropica) by gold nanoparticles. Specifically, atmospheric pressure nonthermal plasma was generated using different diameters (1.0, 2.8, 3.8 and 4.3 mm) of high voltage electrode. Aqueous gold tetrachloride salts (HAuCl4·4H2O) were used as precursor to produce gold nanoparticles. UV-vis spectroscopy and x-ray diffraction were conducted for characterization of the nanoparticles. The optimum condition (a diameter of 1 mm) was chosen to prepare gold nanoparticles, where the grain size was found to be 17 nm. Accordingly, the nanoparticle

... Show More
Scopus (6)
Scopus
Publication Date
Sun Dec 04 2011
Journal Name
Baghdad Science Journal
Evaluation the levels of Plasma Interleukins (IL-8, IFN-?, IL-10) in Preeclamptic Pregnancies
...Show More Authors

This study is to evaluate plasma levels of several cytokines in preeclamptic pregnancies compared to those of healthy pregnancies. Ninety pregnant women with preeclampsia (37 mild & 53 severe) and thirty healthy pregnant women were enrolled in the study. Blood samples were taken and plasma levels of IL-8, IL-10, and IFN-? were measured by enzyme-linked immunosorbent assay (ELISA). Preeclamptic women and their severe cases but not mild cases had significantly (P<0.05) increased levels of plasma IL-8, and IFN-? as compared with healthy pregnancies. By contrast, plasma levels of IL-10 was significantly (P<0.05) increased in healthy pregnant women as compared to all groups of preeclampsia. Preeclampsia is associated with an imbalance betwe

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Plant Archives
STUDY OF THE EFFECT OF COLD PLASMA ON THE REPRODUCTIVE ENDOCRINOLOGY OF MALE RATS
...Show More Authors

Cold atmospheric plasma (CAP) is used widely in medical and biological fields because of non-thermal effected. Direct application of plasma is preferred in medical functions, so, direct application of cold plasma has obtained by the floating electrode dielectric barrier discharge (FE-DBD) system. The purpose of this paper to review the effect of (CAP) on the reproductive hormones (testosterone, LH, E2, progesterone, for male rats. The study appeared that no significant effect on E2 and progesterone hormone for all time of exposure, besides this significant difference in LH hormone (P<0.05) at 15 sec, (P<0.0001) at 30, 90 sec and (P<0.001) at 60 sec of exposure to plasma. Added to that significant difference (P<0.01) at 15, 30, 60 sec and no

... Show More
View Publication Preview PDF