Preferred Language
Articles
/
pIbAN4YBIXToZYALjX9S
Design of tubular moving magnet linear alternator for use with an external combustion - free piston engine
...Show More Authors

Scopus Crossref
Publication Date
Sat Jun 18 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Development of novel paracetamol/naproxen co-crystals with an improvement in naproxen solubility.
...Show More Authors

Co-crystals are new solid forms of drugs that could resolve more than one problem associated with drugs formulations like solubility, stability, bioavailability, mechanical and tableting properties. A preliminary theoretical study for estimating the possible bonding between the co-crystal components (paracetamol and naproxen) was performed using the ChemOffice program. The results revealed a high possibility for bonding between paracetamol and naproxen and indicated the ability of molecular mechanics study to predict the co-crystal design.

       In this work, four different methods were used for the preparation of three different ratios 1:1, 2:1, and 1:2 of paracetamol:naproxen co-crystals. The four

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Thu Jun 30 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Study the Efficiency of Drilling With Casing Operation in an Iraqi Oil Field
...Show More Authors

Drilling with casing (DWC) can be considered as a modern drilling technique in which both of drilling and casing operations done in the same time by using the casing to transfer the hydraulic and mechanical power to the bit instead of traditional drilling string. To overcome oil well control, minimizing the total cost through enhancing drilling efficiency, drilling with casing was proposed as an enabling technology.

   Two surface sections (17 1/2 - and 12 1/4- inch) were drilled successfully in Rumaila oil field with  casing strings which reached 655m and 1524m measured depths respectively.

   By using DWC technique, the total drill/case phase time was reduced up to 20% comparing to conventional

... Show More
View Publication Preview PDF
Publication Date
Wed Apr 30 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The initial stability of dental implant with horizontal plate (An in vitro study)
...Show More Authors

Background: The Initial (primary) stability is one of the factors that play an important role in the success of the dental implants. The purpose of this study was to evaluate the initial stability of dental implant with horizontal plate by using five analytical tests: insertion torque, removal torque, resonance frequency analysis, push-in test and pull-out test. Materials and methods: Two different lengths of dental implants (5mm and 10mm) were tested in this study; each dental implant was 4mm in diameter with a square threads shape of 1mm pitch and 0.5mm depth. The crestal area was 4.2mm diameter contained a right angle margin circumferential ring while the apical area was tapered with two self-tapping grooves. In this study, the initial s

... Show More
View Publication Preview PDF
Publication Date
Sun May 22 2022
Journal Name
International Journal Of Early Childhood Special Education
The impact of an instructional-learning design based on the brain- compatible model in systemic thinking among first intermediate grade female students in Mathematics
...Show More Authors

The research aimed to identify “The impact of an instructional-learning design based on the brain- compatible model in systemic thinking among first intermediate grade female students in Mathematics”, in the day schools of the second Karkh Educational directorate.In order to achieve the research objective, the following null hypothesis was formulated:There is no statistically significant difference at the significance level (0.05) among the average scores of the experimental group students who will be taught by applying an (instructional- learning) design based to on the brain–compatible model and the average scores of the control group students who will be taught through the traditional method in the systemic thinking test.The resear

... Show More
Publication Date
Mon Apr 01 2019
Journal Name
Biochem. Cell. Arch
Improvement the surface properties of metal valves used in agriculture engine by using CO<inf>2</inf> laser beam
...Show More Authors

Preview PDF
Scopus (8)
Scopus
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Hair Is An Indicator Oe Human Pollutants With The Toxic Substances
...Show More Authors

Hair is an excellent indicator for abnormal concentration of toxic elements , In this study a random samples from girls hair of 12 cm long were irradiated by a flux of neutrons (4x10^ n/ cm^.s) obtained from an Am-Be neutron source of 5-Ci activitity . The y-ray activity measurements were carried out by using a " 5x5 " well- type Nal (Tl) detector. The study indicates clearly that the maximum concentration of elements was at about 7 cm hair length.

View Publication Preview PDF
Publication Date
Wed Mar 23 2022
Journal Name
Journal Of Educational And Psychological Researches
The extent of the social worker’s use of group discussion technique in professional practice with school activity groups in Tubas Governorate schools
...Show More Authors

This study aimed at identifying the extent to which the social worker used the techniques of group discussion in the professional practice with the groups of school activity in the schools of Tubas governorate in light of some variables (gender, years of experience, academic qualification). The analytical descriptive method was used due to its suitability for the objectives of the study.  A questionnaire was designed to collect data that included (30) items, distributed in three areas .The validity and reliability of the tool were verified and then distributed to the study sample.

 

The results of the study showed that the highest averages were in the discussion stage domain, where the pre-discussion stage was m

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 01 2021
Journal Name
Journal Of Economics And Administrative Sciences
Comparison of Some Semi-parametric Methods in Partial Linear Single-Index Model
...Show More Authors

The research dealt with a comparative study between some semi-parametric estimation methods to the Partial linear Single Index Model using simulation. There are two approaches to model estimation two-stage procedure and MADE to estimate this model. Simulations were used to study the finite sample performance of estimating methods based on different Single Index models, error variances, and different sample sizes , and the mean average squared errors were used as a comparison criterion between the methods were used. The results showed a preference for the two-stage procedure depending on all the cases that were used

View Publication Preview PDF
Crossref
Publication Date
Wed Aug 16 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Constructing and Solving the System of Linear Equations Produced From LFSR Generators
...Show More Authors

 

Linear Feedback Shift Register (LFSR) systems are used  widely in stream cipher systems field. Any system of LFSR's which wauldn't be attacked must first construct the system of linear equations of the LFSR unit. In this paper methods are developed to construct a system of linear/nonlinear equations of key generator (a LFSR's system) where the effect of combining (Boolean) function of LFSR is obvious. Before solving the system of linear/nonlinear equations by using one of the known classical methods, we have to test the uniqueness of the solution. Finding the solution to these systems mean finding the initial values of the LFSR's of the generator. Two known generators are used to test and apply the ideas of the paper,

... Show More
View Publication Preview PDF
Publication Date
Sat Aug 31 2019
Journal Name
Iraqi Journal Of Physics
Quality assurance of the linear accelerator device using Star Track and Perspex
...Show More Authors

In this study, the quality assurance of the linear accelerator available at the Baghdad Center for Radiation Therapy and Nuclear Medicine was verified using Star Track and Perspex. The study was established from August to December 2018. This study showed that there was an acceptable variation in the dose output of the linear accelerator. This variation was ±2% and it was within the permissible range according to the recommendations of the manufacturer of the accelerator (Elkta).

View Publication Preview PDF
Crossref (1)
Crossref