This paper proposes a new method to tune a fractional order PID controller. This method utilizes both the analytic and numeric approach to determine the controller parameters. The control design specifications that must be achieved by the control system are gain crossover frequency, phase margin, and peak magnitude at the resonant frequency, where the latter is a new design specification suggested by this paper. These specifications results in three equations in five unknown variables. Assuming that certain relations exist between two variables and discretizing one of them, a performance index can be evaluated and the optimal controller parameters that minimize this performance index are selected. As a case study, a third order linear time invariant system is taken as a process to be controlled and the proposed method is applied to design the controller. The resultant control system exactly fulfills the control design specification, a feature that is laked in numerical design methods. Through matlab simulation, the step response of the closed loop system with the proposed controller and a conventional PID controller demonstrate the performance of the system in terms of time domain transient response specifications (rise time, overshoot, and settling time).
The aim of the present study is to evaluate the effectiveness of using Art as therapy to reduce the symptoms of Attention Deficit Hyper Activity Disorder (ADHD), in primary school children.
A clinical approach was used to test the validity of the hypothesis of our study, conducted on two second and fourth-year primary school pupils from Algiers, aged 7 and 9 years respectively.
In addition to the clinical observation and interview, we made use of the "Conners" scale for a (pre and post intervention) ADHD assessment, consisting of a combination of Art media in the form of mosaic works on purposely prepared panels. After 10 therapy sessions, results revealed the effectiveness of Art therapy in reducing ADHD in primary education
The project has been described the design and construction of a reliable optical testing platform used for evaluate the reflectivity of metal surfaces treated with special paintings required for laser beam attenuation. The platform comprises an Nd-YAG laser system which has been designed and fabricated with specifications to be compatible with their corresponding in laser range finder transmitters used for various applications. The reflectivity of various attenuating paintings, at different detection angles, has been observed. Moreover, the variation of the reflected energy with painting type and metal type to be painted has been studied experimentally. Results illustrated the existence of a definite angle, at which the reflectivity was max
... Show MoreBackground: Understanding the challenges facing nurses toward providing care to patients with cerebrovascular accidents is the initial step in developing strategies to address these challenges, thereby ensuring high-quality care. Aim: The study aimed to assess the challenges experienced by nurses in delivering care to patients with CVAs in neurological wards. Results: Of the 80 questionnaire participants in the qualitative part, (MS = 0.66) reported a "moderate" rating as an overall assessment. These challenges are divided into workload (MS = 0.53) at a moderate rate, the psychological burden (MS = 0.85) at a high rate, the supporting materials (MS = 0.85) at a high rate, the sense of responsibility (MS = 0.77) at a high rate, and the role
... Show MoreThis study aimed to explain the criteria of managers at different levels of nursing in selecting effective nursing diagnosis.
In conventional content analysis, 10 nursing managers at different levels including head nurse, supervisor, and nursing manager were interviewed. Data was collected with semi-structured interviews and a narrative approach. Data analysis was performed using the Zhang–Wildemuth method simultaneously with sampling.
Atmospheric transmission is disturbed by scintillation, where scintillation caused more beam divergence. In this work target image spot radius was calculated in presence of atmospheric scintillation. The calculation depend on few relevant equation based on atmospheric parameter (for Middle East), tracking range, expansion ratio of applied beam expander's, receiving unit lens F-number, and the laser wavelength besides photodetector parameter. At maximum target range Rmax =20 km, target image radius is at its maximum Rs=0.4 mm. As the range decreases spot radius decreases too, until the range reaches limit (4 km) at which target image spot radius at its minimum value (0.22 mm). Then as the range decreases, spot radius increases due to geom
... Show MoreThe study aims to reach a common point that achieves a balance between two interests, which are generally in conflict with the public interest and the interest of the individual owner of private property, by extrapolating the provisions of the constitutional judiciary that include the protection of private property, and this protection extends to every right of financial value and is not limited to a specific type, but It included everything that can be estimated with money, as ownership is no longer an advantage for the owner, but rather has become a right for him and a social function. The tax is imposed on what is derived from it, but if there is a need to prejudice it, the conditions, limits and restrictions expressly stipulated in the
... Show MoreBackground:- Cholesterol is high in ascetic fluid due
to malignancy and other causes of exudates.
Objective:-To use cholesterol as a marker to
differentiate between exudative and transudative
ascetic fluid and to compare that with other routine
parameters.
Methods:-Twenty eight patients were included in this
study 17 females with mean age of 41.9 years, 11
males with mean age of 48.2 years. The patients were
divided in group I suspected transudate, and group II
suspected exudate according to history and clinical
examination.
Ascetic fluid samples were sent for total protein,
albumin, and cholesterol measurement blood samples
were sent for serum protein and albumin measurement.
Results:-In this