Preferred Language
Articles
/
omFiL5kBdMdGkNqjmiOh
Synthesis, characterization and Study of the physical properties of some new silicone polymers
...Show More Authors

This study involves the synthesis of a new class of silicon polymers, designated as P1-P7, derived from dichlorodimethylsilane (DCDMS) in combination with various organic compounds (Schiff bases prepared from different amines and appropriate aldehydes or ketones) [I-V] through condensation polymerization. The structures of all monomers and polymers were characterization by FTIR and 1HNMR spectroscopy (for some polymers). The results of thermogravimetric analysis (TGA) and differential scanning calorimetry DSC test show stable thermal behaviour. Polymers with a higher concentration of aromatic rings in their repeating structural units exhibited a higher temperature for weight loss, indicating increased thermal stability. Thermal measurements reflect the fact that all the polymers prepared in this study possess thermal stability, and the most thermally stable are the polymers that contain more phenyl rings. The inhibitory feature of the prepared polymers is studied through many tests, which include measuring the erosion rate through methods known as weight loss and scanning electron microscopy tests. In the weight loss method, the inhibiter gives good efficiency in protecting aluminium metal, to reach the inhibition efficiency to 83% using polymer P5 inhibitor with concentration of 0.15 in 0.1 M solution of NaOH. On the other hand, P4 it showed the lowest inhibition efficiency of 16.74% at a concentration of 0.05. Scanning electron microscopy (SEM) images showed that a high corrosion inhibition efficiency of the polymers in NaOH solution (0.1 M), while the metal surface under the corrosion containing the inhibitors showed lower corrosion than that which could be found on the same metal surface, that is located in a completely empty media of the barrier and also clearly showed the protective layer on the surface. Viscosity testing in dimethylsulfoxide solvent showed that the true viscosity increases three fold when the concentration increases from 0.1 to 0.7. The results also showed that copolymer P7 has a higher viscosity.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Mar 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Manganese Ions (Mn2+) from a Simulated Wastewater by Electrocoagulation/ Electroflotation Technologies with Stainless Steel Mesh Electrodes: Process Optimization Based on Taguchi Approach
...Show More Authors

This study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sat Mar 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Manganese Ions (Mn2+) from a Simulated Wastewater by Electrocoagulation/ Electroflotation Technologies with Stainless Steel Mesh Electrodes: Process Optimization Based on Taguchi Approach
...Show More Authors

This study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis of variance (ANO

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Tue May 01 2012
Journal Name
Iraqi Journal Of Physics
Argon plasma needle source
...Show More Authors

Non thermal argon plasma needle at atmospheric pressure was generated. The experimental set up is based on very simple and low cost electric components that generate electrical field sufficiently high at the electrodes to ionize various gases, which flow at atmospheric pressure. The high d.c power supply is 7.5kV peak to peak, the frequency of the electrical field is 28kHz, and the plasma power less than 15W. The plasma is generated using only one electrode. In the present work the voltage and current discharge waveform are measured. Also the temperature of the working Ar gas at different gas flow and distances from the plasma electrode tip was recorded

View Publication Preview PDF
Publication Date
Fri Dec 01 2017
Journal Name
Journal Of Colloid And Interface Science
Stabilising nanofluids in saline environments
...Show More Authors

Nanofluids (i.e. nanoparticles dispersed in a fluid) have tremendous potential in a broad range of applications, including pharmacy, medicine, water treatment, soil decontamination, or oil recovery and CO2 geo-sequestration. In these applications nanofluid stability plays a key role, and typically robust stability is required. However, the fluids in these applications are saline, and no stability data is available for such salt-containing fluids. We thus measured and quantified nanofluid stability for a wide range of nanofluid formulations, as a function of salinity, nanoparticle content and various additives, and we investigated how this stability can be improved. Zeta sizer and dynamic light scattering (DLS) principles were used to invest

... Show More
Scopus (121)
Crossref (116)
Scopus Clarivate Crossref
Publication Date
Mon Mar 18 2019
Journal Name
Baghdad Science Journal
Enhancement of hydrothermally Co <sub>3</sub> O <sub>4</sub> thin films as H <sub>2</sub> S gas sensor by loading yttrium element
...Show More Authors

The gas sensing properties of Co3O4and Co3O4:Y nano structures were investigated. The films were synthesized using the hydrothermal method on a seeded layer. The XRD, SEM analysis and gas sensing properties were investigated for Co3O4and Co3O4:Y thin films. XRD analysis shows that all films are polycrystalline in nature, having a cubic structure, and the crystallite size is (11.7)nm for cobalt oxide and (9.3)nm for the Co3O4:10%Y. The SEM analysis of thin films obviously indicates that Co3O4possesses a nanosphere-like structure and a flower-like structure for Co3O4:Y.The sensitivity, response time and recovery time to a H2S reducing gas were tested at different operating

... Show More
Publication Date
Thu Jan 06 2022
Journal Name
Iraqi National Journal Of Nursing Specialties
Effectiveness of an Instructional Program on Patientsꞌ Knowledge about Home Safety While Receiving Anti -Cancer Medications at Al- Karama Teaching Hospital in Al-Kut City
...Show More Authors

Objectives: To determine the effectiveness of the instructional program on patients’ knowledge about home safety while receiving anti-cancer treatment at  Al- Karama Teaching Hospital in Al-Kut City.

Methodology:   A quasi-experimental design is conducted through the application of a pre-test and post-test approach for the study and control groups from February 5th, 2020 to April 25th, 2020. A non–probability (purposive) sample of (50) patients treated at the Blood Disease and Oncology Center is selected and divided into two groups. Each group contains (25) patients as control and study groups. An instrument is constructed that is comprised of two parts; t

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 01 2024
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Assessment &lt;b&gt;&lt;/b&gt;of Serum P53 Protein Level in Adult Patients with Acute Myeloid Leukemia in Correlation with Response to Treatment
...Show More Authors

Background: Acute myeloid leukemia (AML) is an adult leukemia characterized by rapid proliferation of undifferentiated myeloid precursors, leading to bone marrow (BM) failure and impaired erythropoiesis. The p53 tumor suppressor protein regulates cell division and inhibits tumor development by preventing cell proliferation of altered or damaged DNA. It orchestrates various cellular reactions, including cell cycle arrest, DNA repair, and antioxidant properties. Objectives: To investigate the relationship of P53 serum level with hematological findings, remission, and survival status in de novo AML patients. Methods: This is a cross-sectional study that enrolled 63 newly diagnosed de novo AML patients, and 15 sex- and age-matched healt

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Annals Of Tropical Medicine & Public Health
Newly developed method for determination of methyldopa drug using ammonium ceric (IV) nitrate by continuous flow injection analysis via homemade NAG-ADF-300-2 analyser
...Show More Authors

A new, simple, sensitive and fast developed method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation a burgundy color complex between methyldopa andammonium ceric (IV) nitrate in aqueous medium using long distance chasing photometer NAG-ADF-300-2. The linear range for calibration graph was 0.05-8.3 mmol/L for cell A and 0.1-8.5 mmol/L for cell B, and LOD 952.8000 ng /200 µL for cell A and 3.3348 µg /200 µL for cell B respectively with correlation coefficient (r) 0.9994 for cell A and 0.9991 for cell B, RSD % was lower than 1 % for n=8. The results were compared with classical method UV-Spectrophotometric at λ max=280 n

... Show More
Crossref (3)
Crossref
Publication Date
Fri May 03 2019
Journal Name
Journal Of Physical Education
Effect Special Exercises &amp; Electrical Muscle Stimulation In Maximum Strength Balance by indication Electrical Activity for Muscles on Both Sides of Body For Disabled Weightlifters
...Show More Authors

MJ Abbas, AK Hussein, Journal of Physical Education, 2019

View Publication
Publication Date
Wed Jan 01 2025
Journal Name
Aip Conference Proceedings
Determination of cefotaxime-sodium at nanoscale level by a microflow injection cell via measuring turbidity using five irradiation sources (WSLEDs) with a single solar cell
...Show More Authors

This work presents a completely new develop an analyzer, named NAG-5SX1-1D-SSP, that is simple, accurate, reproducible, and affordable for the determination of cefotaxime sodium (CFS) in both pure and pharmaceutical drugs. The analyzer was designed according to flow injection analysis, and conducted to turbidimetric measurements. Ammonium cerium nitrate was utilized as a precipitating agent. After optimizing the conditions, the analysis system exhibited a linear range of 0.008-27 mmol. L-1 (n=29), with a limit of detection of 439.3 ng/sample, a limit of quantification of 0.4805 mg/sample, and a correlation coefficient of 0.9988. The repeatability of the responses was assessed by performing six successive injections of CFS at concentra

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref