Sub-threshold operation has received a lot of attention in limited performance applications.However, energy optimization of sub-threshold circuits should be performed with the concern of the performance limitation of such circuit. In this paper, a dual size design is proposed for energy minimization of sub-threshold CMOS circuits. The optimal downsizing factor is determined and assigned for some gates on the off-critical paths to minimize the energy at the maximum allowable performance. This assignment is performed using the proposed slack based genetic algorithm which is a heuristic-mixed evolutionary algorithm. Some gates are heuristically assigned to the original and the downsized design based on their slack time determined by static timing analysis. Other gates are subjected to the genetic algorithm to perform an optimal downsizing assignment taking into account the previous assignments. The algorithm is applied for different downsizing factors to determine the optimal dual size for low energy operation without a performance degradation. Experimental results are obtained for some ISCAS-85 benchmark circuits such as 74283, 74L85, ALU74181, and 16 bit ripple carry adder. The proposed design shows an energy per cycle saving ranged from (29.6% to 56.59%) depending on the utilization of available slack time from the off-critical paths. © School of Engineering, Taylor’s University.
Antioxidant status imbalance and inflammatory process are cooperative events involved in type 2 diabetes mellitus. This study aimed to investigate superoxide dismutase as a potential biomarkers of antioxidant imbalance, matrix-metaloprotinase-9, and interleukin -18 as biomarkers of inflammation in serum and to estimate the effects of other confounding factors gender, age and finally measuring the relation among the interested biomarkers.
This case - control study included 50 patients, and 45 of healthy subjects matched age –gender were also enrolled in this study as a control group. The focused  
... Show MoreDirectional Compact Geographic Forwarding (DCGF) routing protocol promises a minimal overhead generation by utilizing a smart antenna and Quality of Service (QoS) aware aggregation. However, DCGF was tested only in the attack-free scenario without involving the security elements. Therefore, an investigation was conducted to examine the routing protocol algorithm whether it is secure against attack-based networks in the presence of Denial-of-Service (DoS) attack. This analysis on DoS attack was carried out using a single optimal attacker, A1, to investigate the impact of DoS attack on DCGF in a communication link. The study showed that DCGF does not perform efficiently in terms of packet delivery ratio and energy consumption even on a sin
... Show MoreBackground: Echocardiography has an important role to follow up patients with Iatrogenic atrial septaldefect (IASD) and after Catheter ablation during electro-physiological study.Objectives: evaluating the impact of non-invasive Transthoracic Echocardiography (TTE) parameters(LAVI, LVEF, ASD size and E/e`) post radiofrequency ablation of left atrial arrhythmia.Patients and methods: for the evaluation of the atrial septal defect, a transthoracic echocardiography(TTE) was used in patients who underwent left atrial arrhythmia ablation, enrolled in prospective studyin the Iraqi center for cardiac diseases, in cooperation with university of Baghdad /college of medicineResults: The outcomes of the present study were assessed according to
... Show MoreObjective(s): To assess mothers' practices toward children with steroid – sensitive Nephrotic Syndrome (SSNS) who
are visiting nephrology consultation units, and to find out the relationships between their practices and the
demographical data for mother and child.
Methodology: A descriptive study was carried out at nephrology consultation units of Baghdad pediatrics hospitals
(Child's Central Pediatric Teaching Hospital, Al-kadimiyia Teaching Hospital, and Welfare Teaching Hospital) started
from February 18th to the end of July 2009. A purposive sample of (80) mothers who company their children were
selected. The data were collected through a constructed questionnaire, with two parts; the first part is concerned with<
الأهداف: تهدف الدراسة إلى التعرف على مستوى نزاع العمل والأسرة لدى الممرضات في المستشفيات التعليمية في مدينة
الناصرية , تحديد العلاقة بين نزاع العمل والاسرة و عمر الممرضات في المستشفيات التعليمية في مدينة الناصرية.
منهجية البحث: تم إجراء دراسة ذات تصميم وصفيي في المستشفيات التعليمية بمدينة الناصرية خلال الفترة من 1 نوفمبر 2020 إلى 1 أبريل 2021 من أجل تحديد ا
... Show MoreIn cooling water systems, cooling towers play a critical role in removing heat from the water. Cooling water systems are commonly used in industry to dispose the waste heat. An upward spray cooling water systems was especially designed and investigated in this work. The effect of two nanofluids (Al2O3/ water, black carbon /water) on velocity and temperature distributions along reverse spray cooling tower at various concentrations (0.02, 0.08, 0.1, 0.15, and 0.2 wt.%) were investigated, beside the effect of the inlet water temperature (35 ,40, and 45 ͦ C) and water to air flow ratio (L/G) of 0.5, 0.75, and 1. The best thermal performance was found when the working solution contained 0.1 wt.% for each of Al2
... Show More