Hydrophilic Interaction Chromatography Analysis of Esculin in Ointments with UV Detection
...Show More Authors
Background:

Esculin (ESCN) is used in the pharmaceutical industry with intravenous effect, stimulant and anti-inflammatory capillaries, like vitamin P. It is a significant component of many anti-inflammatory remedies such as esqusan, esflazid and anavenol [14]. It is also found in numerous other remedies available in the market such as proctosone, anustat, and ariproct.

Objective:

To determine experimental conditions, to elucidate retention behavior of esculin in HILIC mode. Moreover, to suggest new ways to separate and determinate esculin in ointments.

Methods:

Two hydrophilic columns were obtained by attaching molecules of sulfobetaine to polystyrene- divinylbenzene particles were studied for chromatographic separation of esculin. The various lengths of the chain are used as an investigative instrument for esculin retention conduct. The change of ACN percentage, buffer concentrations and pH of mobile phase in order to study the retention conduct of esculin.

Results:

A mixed mode hydrophilic interaction and ion exchange is the separation mechanism of esculin. A calibration graph was created for two columns. The concentration range was 8-1200 ng.ml-1, LOD 2.33 and 1.40, RSD% 0.31-1.02, , LOQ 7.07 and 4.25 ng.ml-1, Erel% 0.83 ± 0.68 and 0.545 ± 0.45, Recovery% 100.86 ± 0.68 and 1054 ± 0.45.

Conclusion:

The findings of the current study introduced new ZIC-HILIC methods for the separation and quantitation of esculin.

Scopus Clarivate Crossref
View Publication
Publication Date
Sat Mar 29 2025
Journal Name
Jurnal Hama Dan Penyakit Tumbuhan Tropika
Detection and biocontrol of Tobamovirus tabaci infecting tomato in Iraq
...Show More Authors

The antiviral activity of leaf extracts from Datura stramonium and tomato plants inoculated with TMV, combined with 20% skimmed milk, was investigated. A TMV isolate was confirmed using bioassay, serological, and molecular approaches and subsequently used to inoculate plants. Tomato plants, both pre- and post-inoculated with TMV, were sprayed with leaf extracts from either TMV-free or infected plants, alone or mixed with 20% skimmed milk. Enzyme-linked immunosorbent assay (ELISA) using tobamovirus-specific antibodies and local lesion tests were conducted to assess antiviral activity based on virus concentration and infectivity in treated plants. The experiment followed a completely randomized design (CRD), and the Least Significant

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Dec 12 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Detection of Polyomavirus BK and JC in kidney Transplant Recipients
...Show More Authors

objectives: To investigate the polyomaviruses (BK, JC) in asymptomatic kidney transplant recipients and healthy persons as control. It is one of the first reports on serological detection and molecular characterization that describes the circulation of polyomaviruses (BKV, JCV) have been done in Iraq recently. Methodology: The present study was designed as prospective case control study was done during the period from November 2015 to August 2016. Total of 97 serum and urine samples were collected randomly from 25 healthy control person and 72 renal transplant recipients, attending Iraqi Renal Transplantatio

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 27 2023
Journal Name
Icst Transactions On Scalable Information Systems
Tools and Process of Defect Detection in Automated Manufacturing Systems
...Show More Authors

INTRODUCTION: A range of tools and technologies are at disposal for the purpose of defect detection. These include but are not limited to sensors, Statistical Process Control (SPC) software, Artificial Intelligence (AI) and machine learning (ML) algorithms, X-ray systems, ultrasound systems, and eddy current systems. OBJECTIVES: The determination of the suitable instrument or combination of instruments is contingent upon the precise production procedure and the category of flaw being identified. In certain cases, defects may necessitate real-time monitoring and analysis through the use of sensors and SPC software, whereas more comprehensive analysis may be required for other defects through the utilization of X-ray or ultrasound sy

... Show More
View Publication
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Tue Jan 01 2013
Journal Name
كلية التربية الجامعة المستنصرية
Study the electron drift velocity in gas mixtures of CF3I with N2 obtained from Boltzmann equation analysis
...Show More Authors

Publication Date
Wed Jan 01 2014
Journal Name
كلية التربية -الجامعة المستنصرية
study the electron drift velocity in gas mixtures of SF6 with N2 obtained from Boltzmann equation analysis
...Show More Authors

Publication Date
Mon Aug 01 2016
Journal Name
Enzyme And Microbial Technology
In Search of the E. coli Compounds that Change the Antibiotic Production Pattern of Streptomyces coelicolor During Inter-species Interaction
...Show More Authors

View Publication
Scopus (7)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2011
Journal Name
مجلة الانبار للعلوم الزراعية
Effect of urea and superphosphate fertilizers and it's their interaction in some chemical properties of wheat grain ( Triticum aestivum L.)
...Show More Authors

An experiment was carried out by using post in kalar horticulture Station/Sulaimania province on soil taked from once region sields during growing season of 2008-2009. The objective was to study adding increasing levels of urea fertilizer which is (0.0, 0.20, 0.40, 0.80) gm/Pot and superphosphate fertilizer which is (0.0, 0.24, 0.48) gm/pot in some chemical properties of grain for wheat IPA 95. This experiment was carried out by completely randomized design (CR D) with three replications. Results in dictated of clear increase in all the studied characteristics (concentration for each nitrogen, phosphorus and potassium and carbohydrate percentage with increasing levels of fertilizers).

Publication Date
Wed Feb 22 2017
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
DETECTION OF ENTEROTOXINS OF Staphylococcus aureus IN MILK AND LOCOLLY SOFT CHEESES IN BAGHDAD CITY: DETECTION OF ENTEROTOXINS OF Staphylococcus aureus IN MILK AND LOCOLLY SOFT CHEESES IN BAGHDAD CITY
...Show More Authors

This study aimed to detect of contamination of milk and local soft cheese with Staphylococcus aureus and their enterotoxins with attempt to detect the enterotoxin genes in some isolates of this bacteria. A total of 120 samples, 76 of raw milk and 44 of soft cheese were collected from different markets of Baghdad city. Enterotoxins in these samples were detected by VIDAS Set 2 system and it was found that enterotoxin A is present in a rate of 44.74% in milk samples and in a rate 54.50% in cheese samples. While other enterotoxins B, C, D, E were not found in any rate in any samples.
Through the study 60 isolates obtained from milk and cheeses were identified as Staphylococcus aureus by cultural, morphological and biochemical test by u

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 12 2012
Journal Name
Institute Of Advanced Studies In English
Cohesive Devices in English and Arabic with Analysis of Two of Hemingway's Novels and their Translations
...Show More Authors

DBN Rashid, 2012 - Cited by 2

View Publication
Publication Date
Tue Sep 01 2020
Journal Name
Baghdad Science Journal
Oxidative Coupling Reaction for Micro Trace Analysis of Mebendazol Residual with p-bromoaniline in Presence of n- bromosuccinimide
...Show More Authors

Rapid, reproducible and accurate method has been developed for the assay for of mebendazol (MBZ) residual assay. The method is based on alkaline hydrolysis of MBZ with sodium hydroxide then oxidation with N-bromosuccinimide (NBS) followed by coupling with 4-Bromoaniline (4-BA) to yield a highly colored product absorbed at maximum 434 nm. Regression analysis of linearity range was found (0.6-2.8) µg.ml-1.  The optimum conditions that affect the oxidation were studied. The developed method was found to be precise with mean value of relative standard deviation (1.153- 1.303) and accurate with relative error (-0.5940-1.7821) .The calculated molar absorptivity and sandal sensitivity values of (29825 L.mol-1.cm-1), 0.0099 µg.cm-2 respe

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref