Background: Deterioration of maxillofacial silicone properties due to microbial colonization is a common problem and leads to the replacement of the prosthesis. Incorporation of the antimicrobial agent into the silicone could be a solution. The purpose of this study was to evaluate the effect of silver-zinc zeolite addition on some mechanical properties of a maxillofacial silicone (VST-50). Materials and methods: Total 120 specimens were fabricated and divided into 3 groups: 40 specimens for tear strength test, 40 specimens for tensile and percentage of elongation tests and 40 specimens for Shore A hardness and surface roughness. Each group was divided into 4 subgroups according to the amount of zeolite added (0% “control”, 0.5%, 1% and 1.5%). One-way ANOVA and Tukey’s HSD tests were used to analyze the study data. FTIR revealed a chemical interaction between zeolite and silicone. Results: Study results revealed a highly significant increase in tear strength (p<0.01) in all experimental subgroups. The tensile strength of 1% filler was significantly higher than the control group (p<0.01) while 0.5% and 1.5% showed a non-significant increase. All experimental groups demonstrated a highly significant decrease in the percentage of elongation and a highly significant increase in roughness (p<0.01). The subgroup with 1.5% zeolite showed a highly significant increase in hardness, other subgroups showed a non-significant increase. Conclusion: The addition of 1% Ag-Zn zeolite improved some mechanical properties of VST-50 maxillofacial silicone.
To study the response of the celery plant to nitrogen fertilization and spray with salicylic acid in the leaves content of nutrients, the research was conducted in one of the fields of the Department of Horticulture and Gardening Engineering / College of Agriculture / University of Baghdad within the 2019-2018 season. The research was carried out as a global experiment and with the design of complete randomized sectors (RCBD) and with three replicates, the first factor included the addition of nitrogen with three levels and its symbol (N) (N1 control), (N2) g / m2 18 ), (N3) 37 g / m2 and the second factor spraying acid salicylic is denoted by
Trace elements concentrations are frequently reported to be a good indicator for diagnosis and prognosis of some disease. The levels of copper, zinc, manganese, and magnesium were measured in serum of two group. Group one contains (52) newborn jaundice patients while the second group contains (20) healthy newborn used as controls.
In this study the concentration of Cu, Zn, Mg, and Mn were measured using atomic absorption spectrophotometer (AAS). It has been found that zinc level is significantly lower in newborn jaundice patients compared with normal subjects at (p<0.05) , also the level of Cu, Mg, and Mn were significantly
... Show MoreThe ceramic composite with different proportions of clay and silica was prepared with a grain size of 70 μm and the weight percentage was selected for four groups (clayx silica100-x) were x q15, 25, 30 and 50. In this manuscript, for each pressured sample, a sintering procedure was carried out for 3 hours under static air and at various sintering temperatures (1000, 1100, 1200, 1400)°C. After sintering, the density, porosity, water absorption, compression strength and thermal conductivity were measured. The best results were obtained using a mixture of 15% clay and 85% silica which were sintering at 1400°C for three hours under air.
In the present paper a low cost mechanical vibration shaker of rotating unbalanced type with uniaxial shaking table was designed and constructed in an attempt to provide opportunities for experimental testing and application of vibration in experimental modal analysis, stress relief of weldments, effect of vibration on heat transfer and seismic testing of civil engineering structures. Also, it provides unexpressive solution to enhance the knowledge and technical skills of students in mechanical vibration laboratory. The shaker consists of a five main parts shaker frame, shaker table, flexible support, drive motor, and eccentricity mechanism. The experimental results show that the amplitude of the shaker is increased with increasing the f
... Show MoreBuckling analysis of composite laminates for critical thermal (uniform and linear) and mechanical loads is reported here. The objective of this work is to carry out theoretical investigation of buckling analysis of composite plates under thermomechanical loads, and experimental investigation under mechanical loads. The analytical investigation involved certain mathematical preliminaries, a study of equations of orthotropic elasticity for classical laminated plate theory (CLPT), higher order shear deformation plate theory (HSDT) , and numerical analysis (Finite element method), then the equation of motion are derived and solved using Navier method and Levy method for symmetric and anti-symmetric cross-ply and angle-ply laminated plates t
... Show More