Background: Menstrual problems with all manifestations ranging from life-threatening bleeding to amen- orrhea are considered patterns of abnormal uterine bleeding (AUB), which is until now a popular reason for referral to the gynaecologic clinic and requires a special diagnostic tool. Objective: To assess the accuracy of hysteroscopy in diagnosing endometrial pathologies and to compare it with sonographic and histopathologic reports. Patients and Methods: A prospective study conducted in the Baghdad Teaching Hospital on 60 Iraqi females having varying complaints from abnormal uterine bleeding in pre- and post-menopausal women, infertility, and chronic pelvic pain with normal or abnormal ultrasound findings. Office hysteroscopy was done and an endometrial biopsy was obtained for histopathology for a period of 10 months between September 2020 and June 2021. Results: The current study showed that hysteroscopy was more accurate in diagnosing sensitivity of endo- metrial poly (100%), fibroids (83%), hyperplasia (84.2%), and cancer (50%) whereas ultrasounds were more accurate in diagnosing sensitivity to endometrial myoma (90%). Hysteroscopy and ultrasound showed low sensitivity in detecting endometrial cancer (50% and 34%, respectively). Conclusion: Although a transvaginal ultrasound was considered an integral part in the diagnosis of endo- metrial pathologies, it can be used for initial investigation, however, when suspecting endometrial pathol- ogy, hysteroscopy can be more advanced for evaluation, immediate treatment of endometrial masses, and obtaining targeted biopsies. Hysteroscopy showed high sensitivity in detecting endometrial polyps.
The existing investigation explains the consequence of irradiation of violet laser on the optic properties of (CoO2) films. The film was equipped by the utilization of semi-computerized spray pyrolysis technique (SCSPT), it is the first time that this technique is used in the preparation and irradiation using a laser in this technique. From the XRD analysis, the crystalline existence with trigonal crystal system was when the received films were processed by continuous violet laser (405 nm) with power (1W) for different laser irradiation time using different number of times a laser scan (0, 6, 9, 12, 15 and 18 times) with total irradiation time(0,30,45,60,75,90 min
NH3 gas sensor was fabricated based on deposited of Functionalized Multi-Walled Carbon Nanotubes (MWCNTs-OH) suspension on filter paper substrates using suspension filtration method. The structural, morphological and optical properties of the MWCNTs film were characterized by XRD, AFM and FTIR techniques. XRD measurement confirmed that the structure of MWCNTs is not affected by the preparation method. The AFM images reflected highly ordered network in the form of a mat. The functional groups and types of bonding have appeared in the FTIR spectra. The fingerprint (C-C stretch) of MWCNTs appears in 1365 cm-1, and the backbone of CNTs observed at 1645 cm-1. A homemade sensi
... Show MoreThis study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis
... Show MoreThis study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis of variance (ANO
... Show MoreThe title compound was synthesized by 2:1 condensation between adamantan-1-ylamine and benzene-1,4- dicarbaldehyde in n-BuOH and produced a good yield 87% of new bis Schiff base. The compound skeleton was affirmed by FTIR, 1H NMR, LC-MS, and X-ray powder diffraction. The structure was solved by a parallel tempering process and refined by using Rietveld refinement. Two adamantan-1-ylimino groups are connected in the anti-positions to the planar central 1,4-dimethylbenzene group. All rings of the adamantyl group possess normal chair conformation.
A new, simple, sensitive and fast developed method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation a burgundy color complex between methyldopa andammonium ceric (IV) nitrate in aqueous medium using long distance chasing photometer NAG-ADF-300-2. The linear range for calibration graph was 0.05-8.3 mmol/L for cell A and 0.1-8.5 mmol/L for cell B, and LOD 952.8000 ng /200 µL for cell A and 3.3348 µg /200 µL for cell B respectively with correlation coefficient (r) 0.9994 for cell A and 0.9991 for cell B, RSD % was lower than 1 % for n=8. The results were compared with classical method UV-Spectrophotometric at λ max=280 n
... Show More