Preferred Language
Articles
/
nxgtiZUBVTCNdQwCHXxZ
Cone Beam Computed Tomographic Evaluation of Schneiderian Membrane Thickness
...Show More Authors

This study aimed to determine the measurements and classification of Schneider membrane thickness correlated to age and sex factors using cone beam computed tomography (CBCT). Methods: The study included CBCT images for 100 maxillary sinuses of 50 consecutive patients, and the thickness of the maxillary sinus membrane (Schneiderian membrane) was measured in coronal view from the lowest point in the floor of the maxillary sinus to the highest point. The thickness of the Schneiderian membrane was classified into 4 types. Results: The study result revealed that out of the total cases, 45% of sinus membranes were classified as type 2, while only 10% were classified as type 4. The most frequent type of membrane thickness diagnosed in the age group 20 to 30 as type 1, whereas in age groups 31 to 40 and 41 to 50, regarding sex, type 4 was more obvious in males with membrane thickening >6 mm. Conclusions: Measurement and classification of sinus membrane thickness can be performed accurately with CBCT, and it is affected by age and sex factors.

Scopus Clarivate Crossref
View Publication
Publication Date
Tue Jun 01 2010
Journal Name
Journal Of Engineering 5263
COUPLED VERTICAL – TORSIONAL AND LATERAL FREE VIBRATION OF THIN-WALLED CURVED BEAM
...Show More Authors

This study is concerned with the derivation of differential equation of motion for the free coupled vertical – torsional and lateral vibration of opened thin-walled curved beams. The curved beam to be considered in this study is of isotropic opened thin – walled (I) section with equal top and bottom flanges. The derivation depends on Hamilton's principle which required finding the potential and kinetic energy of the curved beam section due to internal stresses and all types of movements (Vertical,Torsional and Lateral) .The effect of restrained warping displacement is also considered in this study. Three differential equations are derived for vertical, torsional and lateral movement .and approximate solutions are developed by using the

... Show More
Publication Date
Wed Dec 01 2021
Journal Name
Baghdad Science Journal
Enhancement of Electron Temperature under Dense Homogenous Plasma by Pulsed Laser Beam
...Show More Authors

The applications of hot plasma are many and numerous applications require high values of the temperature of the electrons within the plasma region. Improving electron temperature values is one of the important processes for using this specification in plasma for being adopted in several modern applications such as nuclear fusion, plating operations and in industrial applications. In this work, theoretical computations were performed to enhance electron temperature under dense homogeneous plasma. The effect of   power and duration time of pulsed Nd:YAG laser   was studied on the heating of   plasmas  by inverse bremsstrahlung  for  several values for the electron density ratio. There results for these ca

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Fri Jan 07 2022
Journal Name
Materials
Impact Behavior of Composite Reinforced Concrete Beams with Pultruded I-GFRP Beam
...Show More Authors

The present study experimentally and numerically investigated the impact behavior of composite reinforced concrete (RC) beams with the pultruded I-GFRP and I-steel beams. Eight specimens of two groups were cast in different configurations. The first group consisted of four specimens and was tested under static load to provide reference results for the second group. The four specimens in the second group were tested first under impact loading and then static loading to determine the residual static strengths of the impacted specimens. The test variables considered the type of encased I-section (steel and GFRP), presence of shear connectors, and drop height during impact tests. A mass of 42.5 kg was dropped on the top surface at the m

... Show More
View Publication
Scopus (21)
Crossref (21)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Aip Conference Proceedings
Recovery of methyl orange from aqueous solutions by bulk liquid membrane process facilitated with anionic carrier
...Show More Authors

Dyes are extensively water-soluble and toxic chemicals. The disposing of wastewater rich with such chemicals has severely impacted surface water quality (rivers and lakes). In the current study, an anionic dye, methyl orange, were extracted from wastewater fluids using bulk liquid membranes supplemented with an anionic carrier (Aliquat 336 (QCI)). Parameters including solvent type (carbon tetrachloride and chloroform), membrane stirring speed (100-250 rpm), mixing speed of both phases (50-100 rpm), The feed pH (2-12) and implemented temperature (35-60 °C) were thoroughly analyzed to determine the effect of such variables on extraction effectiveness. Furthermore, the effect of methyl orange (10-50 ppm) in the feed stage and NaOH (0

... Show More
View Publication
Scopus (7)
Crossref (1)
Scopus Crossref
Publication Date
Thu Mar 18 2021
Journal Name
Egyptian Journal Of Chemistry
Investigation of the Influence of Membrane Type on the Performance of Microbial Fuel Cell
...Show More Authors

View Publication
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Feb 05 2024
Journal Name
J Contemp Med Sci | Vol. 10, No. 1, January–february 2024: 77–79
The Validity of Computed Tomography Guided Lung Tru-Cut Biopsies in Achieving Accurate Tissue Results
...Show More Authors

Objective: This study aims to assess the efficacy of CT-guided true-cut biopsy as a less invasive and cost-effective diagnostic technique for peripherally placed lung lesions.

Publication Date
Mon Feb 26 2024
Journal Name
Journal Of Contemporary Medical Sciences
The Validity of Computed Tomography Guided Lung Tru- cut Biopsies in Achieving Accurate Tissue Results
...Show More Authors

Objective: This study aims to assess the efficacy of CT-guided true-cut biopsy as a less invasive and cost-effective diagnostic technique for peripherally placed lung lesions.   Methods: fourty patients with solitary lung nodule were involved in this study, true cut biopsies under Ct guide was taken then processed for routine H&E staining.   Results: different pathological features can be identified with different pathological features giving primary diagnostic screening for lung cancer   Conclusion: CT guided thoracic lesion biopsy is very efficient, cost-effective and less invasive technique when compared with the thoracic surgery

View Publication
Scopus Clarivate Crossref
Publication Date
Sun May 01 2016
Journal Name
Journal Of Multidisciplinary Engineering Science Studies
The Thickness Effects Characterization Properties Of Copper Oxide Thin Films Prepared By Thermal Evaporation Technique
...Show More Authors

In This paper, CuO thin films having different thickness (250, 300 , 350 and 400) nm were deposited on glass substrates by thermal vacuum evaporator. The thermal oxidation of this evaporated film was done in heated glass at temperature (300 in air at one hour. The study of X-ray diffraction investigated all the exhibit polycrystalline nature with monoclinic crystal structure include uniformly grains. Thin film’s internal structure topographical and optical properties. Furthermore, the crystallization directions of CuO (35.54 , 38.70 ) can be clearly observed through an X-ray diffraction analysis XRD, Atomic Force Microscope AFM (topographic image) showed that the surface Characteristics , thin films crystals grew with increases in either

... Show More
Publication Date
Thu Aug 27 2020
Journal Name
European Journal Of Ophthalmology
Comparison of corneal epithelial thickness profile in dry eye patients, keratoconus suspect, and healthy eyes
...Show More Authors
Purpose:

To compare the corneal epithelial thickness profile in patients with dry eyes and keratoconus suspect with normal healthy eyes.

Methods:

The study involved 120 eyes with an age range from 19 to 30 years. Forty eyes had normal corneal topography and no dry eyes. Forty eyes had dry eyes but had normal corneal topography. The last 40 eyes were keratoconus suspect and had no symptoms or signs of dry eyes.

Results:

Central epithelial thickness was not different statistically for all eyes. ( p-value: 0.1). The superior epithelial thickness was 53.5 µm ±3.1 in the control

... Show More
View Publication
Scopus (19)
Crossref (21)
Scopus Clarivate Crossref
Publication Date
Thu May 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Experimental and Numerical Study of Crack Effect on Frequency of Simple Supported Beam
...Show More Authors

In this research the natural frequency of a cracked simple supported beam (the crack is in many places and in different depths) is investigated analytically, experimentally and numerically by ANSYS program, and the results are compared. The beam is made of iron with dimensions of L*W*H= (0.84*0.02* 0.02m), and density = 7680kg/m3, E=200Gpa. A comparison made between analytical results from ANSYS with experimental results, where the biggest error percentage is about (7.2 %) in crack position (42 cm) and (6 mm) depth. Between Rayleigh method with experimental results the biggest error percentage is about (6.4 %) for the same crack position and depth. From the error percentages it could be concluded that the Rayleigh method gives

... Show More
View Publication Preview PDF