The research aims at the possibility of measuring the technical and scale efficiency (SE) of the departments of the College of Administration and Economics at the University of Baghdad for a period lasting 8 years, from the academic year 2013-2014 to 2018-2019 using the method of Applied Data Analysis with an input and output orientation to maintain the distinguished competitive position and try to identify weaknesses in performance and address them. Nevertheless, the research problem lies in diagnosing the most acceptable specializations in the labor market and determining the reasons for students’ reluctance to enter some departments. Furthermore, the (Win4DEAp) program was used to measure technical and scale efficiency (SE) and rely on the data available in the student registration department. As the study included the seven scientific departments in the College of Administration And the economy. However, the results showed that the business administration, finance, and banking departments are distinguished by being the enveloped departments because they operate according to their full efficiency and maintain their peers during the period.
The research aims to design a narrow-band frequency drive amplifier (1.5GHz -1.6GHz), which is used to boost the transmitter amplifier's input signal or amplify the GPS, GlONASS signals at the L1 band.
The Power Amplifier printed circuit board (PCB) prototype was designed using InGaP HBT homogeneous technology transistor and GaAs Heterojunction Bipolar Transistor (HBT) transistor. Two models have been compared; one of the models gave 16dB gain, and the other gave 23dB when using an input power signal (-15dBm). The PCB consumes 2.4W of power and has a physical dimension of 11 x 4 cm.
The aim of this investigation is to study the rote of alkaline phosphatase in mammogenesis and lactogenesis. A total of fortyfemalealbino rats were used and divided according to their physiological states into four groups [ten rats each]. From each deeply ether anesthetized rat, the mammary gland was removed, fixed, quenched in liquid nitrogen and sectioned using SLEE cryostat. The sections were employed for routine haematoxylin and eosin stain and alkaline phosphatase demonstration using the calcium–cobalt method. The obvious finding in the mammary glands of pregnant rat was the presence of thick black rings indicating strong alkaline phosphatase activityaround the basal part of the secretory epithelium of the alveoli. In lactating mamma
... Show MoreBackground: Very low birth weight (VLBW) neonates constitute approximately 4–7 percent of all live births and their mortality is very high.
Objective: to find out if there is a relationship between Very Low Birth Weight Neonates and increased neonatal mortality for age 0 to 7 days.
Methods: A retrospective study of VLBW neonates admitted to NICU at Ibn Al- Baladi Pediatrics and Maternity hospital over one year (2012)were studied, The study period was from April till August 2013. Exclusion criteria were: (1) neonates weighing less than 700 g and with gestational age less than 24 weeks (abortion) (2) death in the delivery room (3) neonates weighing more than 1500 g. (4) Postnatal age more than 7 days. The outcome measure was in-hos
Transient drop in the heart beat or transient heart block (AVB) may be consider the main cause of syncope or presyncope inpatients with bifascicular block and syncope According to the Guidelines for cardiac pacing pacemaker consider part of treatment. Aims of our study were to evaluate whether there is role for EPS in patients BFB and to evaluate the symptoms after pacing. 42 patients were enrolled in this study, with mean age value (63.4± 12.2years), suffer from interventricular conductive defect and syncope; patients underwent EPS on admission time, and pacemaker implantation accordingly and programmed follow up for the device in the last four years. Our patients were 25 (59.5%) male and 17 (40.5%)female, all of them with syncope o
... Show MoreA tunable band pass filter based on fiber Bragg grating sensor using an in-fiber Mach-Zender interferometer with dual micro-cavities is presented. The micro-cavity was formed by splicing together a conventional single-mode fiber and a solid core photonic crystal fiber (SCPCF) with simple arc discharge technique. Different parameters such as arc power, length of the SCPCF and the overlap gap between samples were considered to control the fabrication process. The ellipsoidal air-cavity between the two fibers forms Fabry-Perot cavity. The diffraction loss was very low due to short cavity length. Ellipsoidal shape micro-cavities were experimentally achieved parallel to the propagation axis having dimensions of (24.92 – 62.32) μm of width
... Show MoreNew complexes have been prepared from the new ligand [N1,N5-bis(3-hydroxyphenyl)-2- oxopentanediamide] derived from 2-Oxoglutaric acid and 3-aminophenol. Accordingly its binudear Mn(II),Co(II),Ni(II),Pd(II) and VO(II) complexes were prepared.. These compounds have been characterized by FT-IR, UV-Vis,Mass, 1H-NMR spectra, TGA curve, Chloride containing ,Molar conductance and atomic absorption. The characterization results gave binuclear complexes and pentadentate coordination and tetrahedral geometry for each Cobalt, Nickel, Manganese and Copper complexes otherwise Palladium complex gave a square planar geometry and Vanadium complex gave a square pyramidal geometry and the ligand is tetradentate. The biological activities for the new compoun
... Show MoreIn this research, the influence of the orientation and distance factors on the lowest usable frequency (LUF) parameter has been studied theoretically. The calculations of the (LUF) parameter have been made using the (VOACAP) international communication model for the connection links between the capital Baghdad and many other locations that distributed on different distances and directions over the Middle East region. The results shown in this study indicate there is a slight affection of the link direction (orientation) on the LUF parameter, while the influence of the distance factor is more significant on the values of the LUF parameter. The day/night effect appears for the long distance HF links (i.e. more than a 500 Km)