Background: Poly-ether-ether-ketone(PEEK) has been introduced to many dental fields. Recently it was tested as a retainer wire‎ following orthodontic treatment. This study aimed to investigate the effect of changing the bonding spot size and location on the performance of PEEK retainer wires. Methods: A biomechanical study involving four three-dimensional finite element models was performed. The basic model was with a 0.8 mm cylindrical cross-section PEEK wire, bonded at the center of the lingual surface of the mandibular incisors with 4 mm in diameter composite spots. Two other models were designed with 3 mm and 5 mm composite sizes. The last model was created with the composite bonding spot of the canine away from the center of the crown, closer to the lateral incisor. The linear displacement of the teeth, strains of the periodontal ligament, and stresses in PEEK wire and composite were evaluated. The data was numerically produced with color coded display by the software. Selected values were tabulated and compared among models. Results: The amount of linear displacement and strain was very low. Stresses in the wire and composite were affected by the size and position of the composite bonding spot. The safe limits were identified at 235 MPa for PEEK and 100 MPa for composite. The basic model had a von Mises stress in the PEEK wire of 122.09 MPa, and a maximum principal stress in the composite of 99.779 MPa. Both stresses were within the safe limits, which means a lower risk of failure in PEEK and composite. All other models had stresses that exceeded the safe limit of the composite. The 3 mm composite model was the only one that developed stresses in the wire more than the safe limits of PEEK. Conclusions: Within the limitations of this study, bonding PEEK wires with 4 mm bonding spots to the clinical crown center provided the best mechanical performance of the wires and spots; otherwise, the mechanical properties of the wire and composite would be affected and, therefore, might affect the retention process. Keywords: Retention, PEEK, Finite element analysis
This research aims to study the performance of comedian in the plays of writer Moliere . The problem of research is to answer the following question: How does comedian Moliere's techniques in a number of his plays and funny acts? The research aims at revealing the means used by the comedian in his performance of a comedic character in the number of Moliere plays.
&
... Show MoreThe present study aims at finding out the (effect of the Caroll’s pattern on the second intermediate class pupils' achievement in geography)
The partial experimental design of two groups, experimental and control, with pre-post tests is used. The sample is represented in (74) female pupils. The sample is divided into two groups (38) experimental group and (36) control one. The sample is selected from first intermediate class pupils ( Am Salama Secondary School for girls) \ Baghdad\ Al-karkh-1, for academic year 2015-2016.
The researcher has equalized the two groups in several variables: the previous achievement tests, intelligence, age in months, the scor
... Show More
The current research aims to validate the Effect of technical innovation on human resources management ambidexterity through job embeddedness. The current research was done in Al-Etihad Food Industries Co. Ltd. And within the industrial environment, the research was designed according to the descriptive research. And to achieve the main goal of the research above, the researcher used the questionnaire as a key instrument to collect data through the views of a sample of managers, and employees at the senior, middle and executive management level. The research sample reached (107) individuals, the data were analysed using the statistical packages (SPSS v. 26) and ( SMART PLS v 3. 3. 8) the group of statistical
... Show MoreThis study presents the effect of laser energy on burning loss of magnesium from the holes' drilled in aluminum alloy 5052. High energy free running pulsed Nd:Glass laser of 300 µs pulse duration has been used to perform the experiments. The laser energy was varied from 1.0 to 8.0 Joules, The drilling processes have been carried out under atmospheric pressure and vacuum inside a specially designed chamber. Microhardness of the blind drilled holes has been investigated .The results indicated that the magnesium loss could be manipulated by adjusting the focusing conditions of the laser beam. Almost, the obtained holes were free of cracks with low taper and low sputter deposition. .The holes performed under atmospheric conditions have high
... Show MoreThis study aims to conduct an exhaustive comparison between the performance of human translators and artificial intelligence-powered machine translation systems, specifically examining the top three systems: Spider-AI, Metacate, and DeepL. A variety of texts from distinct categories were evaluated to gain a profound understanding of the qualitative differences, as well as the strengths and weaknesses, between human and machine translations. The results demonstrated that human translation significantly outperforms machine translation, with larger gaps in literary texts and texts characterized by high linguistic complexity. However, the performance of machine translation systems, particularly DeepL, has improved and in some contexts
... Show MoreAbstract: The aim of this study was to evaluate the effect of bone density value in Hounsfield unit derived from cone beam computed tomography (CBCT), and implant dimensions in relation to implant stability parameters namely the resonance frequency analysis and the insertion torque (IT) value. It included 24 patients who received 42 dental implants (DI). The bone density of the planned implant site was preoperatively measured using cone beam computed tomography. The implant stability was measured using Osstell implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. The IT value was categorized as 35 N/cm or > 35 N/cm. The mean (standard deviation) primary stability was 79.58 (5.27) ISQ,
... Show More