Preferred Language
Articles
/
nRZ6VocBVTCNdQwCJEZo
Electron density spectroscopic measurement in Al laser induced plasma
...Show More Authors

Plasma generated by a 1064 nm pulsed Nd: YAG laser with pulse duration of 10 ns concentrated onto an Al solid target under vacuum pressure was examined spectroscopically. The temperature and electron density specifying the plasma were measured by time-resolved spectroscopy of neutral atom and ion line emissions in the time period range of 300–2000 ns. An echelle spectrograph is utilized to appear the plasma emission lines. The temperature was obtained using the spectral line comparison method and the electron density was calculated using the Stark Broadening (SB) method. The electron density was characterized as a function of laser pulse energy. The time range where the plasma is optically thin and is also in local thermodynamic equilibrium (LTE), significant for the laser-produced plasma (LPP) which was evaluated from the temporal profile of the intensity ratio of two Al I lines (λ1=380.581nm, 398.014nm, and 393.1996nm), (λ2= 586.781nm). It is found to be 700–1000 ns.

Publication Date
Sun Nov 01 2020
Journal Name
Iraqi Journal Of Laser
Urinary Tract Lithotripsy Using Holmium: YAG (2100nm) Laser
...Show More Authors

Background: Laser urinary stone lithotripsy is an established endourological modality. Ho:YAG(2100nm) laser have broadened  the indications for ureteroscopic stone managements  to include larger stone sizes throughout the whole urinary tract.

Purpose: To evaluate the effectiveness and safety of Holmium: YAG(2100nm) laser lithotripsy with a semirigid uretero scope for urinary stone calculi in a prospective cohort of 17 patients.

Patients and Methods: Holmium: YAG(2100nm) laser lithotripsy was performed with a semirigid ureteroscope in 17 patients from September 2016 to December  2016. Calculi were located in the lower ureter in 9 patients (52.9%), the midure

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 06 2011
Journal Name
Baghdad Science Journal
Laser Effect on Fatique Resistance of Carbon Steel
...Show More Authors

Laser beam has been widely used to improve the mechanical properties of the metals. It used for cutting, drilling, hardening, welding……etc. The use of Laser beam has many features in accuracy and speeding in work, also in the treatment of metals locally, and in the places that is hard to reach by traditional ways. In this research a surface treatment was done to medium carbon steel (0.4%C) which is common kind of steel that is used in industry. Pulsing Neodymium -YAG Laser has been used and 1.06 micrometer wave length and 5 msec and the distance is about 30 centimeter between the exit area of the Laser beam from the system and the piece that treated . We are going to check the fatigue resistance for samples that is

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Sep 11 2018
Journal Name
Iraqi Journal Of Physics
Electrical glow discharges and plasma parameter of planar sputtering system for silver target
...Show More Authors

DC planar sputtering system is characterized by varying discharge potential of (250-2000 volt) and Argon gas pressures of (3.5×10-2 – 1.5) mbar. The breakdown voltage for silver electrode was studied with a uniform electric field at different discharge distances, as well as plasma parameters. The breakdown voltage is a product of the Argon gas pressure inside the chamber and gab distance between the electrodes, represent as Paschen curve. The Current-voltage characteristics curves indicate that the electrical discharge plasma is working in the abnormal glow region. Plasma parameters were found from the current-voltage characteristics of a single probe positioned at the inter-cathode space. Typical values of the electron temperature an

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 23 2021
Journal Name
Iraqi Journal Of Science
Electrical Properties and Optimum Conditions of A Home-Made Magnetron Plasma Sputtering System
...Show More Authors

     In this work, the electrical properties and optimum conditions of the plasma sputtering system have been studied. The electrical properties such as Paschen's curve, current-voltage, current pressure relations, the strength of magnetic field as a function of inter-electrode distance, the influence of gas working pressure and argon-oxygen ratio on the electrical characterization were studied to determine the basic optimum condition of the system operation. the discharge current as a function of discharge voltage showed high discharge current at 2.5 cm.  These parameters represent the basic conditions to operate any plasma sputtering system which are the right behavior to build up and design the discharge an el

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Oct 01 2010
Journal Name
Iraqi Journal Of Physics
Analysis of Initiation and Growth of Plasma Channels Within Non-Mixed Dielectric Liquids
...Show More Authors

Pre-breakdown phenomenon was investigated within the two, non-mixed dielectric liquids; transformation oil and cresol. Finite element technique was used to follow the initiation and growth of plasma channels (streamer discharge) within pin-plane configuration. That was done for different spacing between the pin-electrode and the liquid-liquid interface. Streamer growth model assumed that, the streamer initiation occurs at the region of the highest value of electric field. Our study shows that the streamer initiates at the tip of the pin and growths toward the other electrode. The study shows, too, that the streamer path controlled by the difference of permittivity of the two liquids and spacing distance of the liquid-liquid interface fro

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 31 2022
Journal Name
Iraqi Journal Of Science
Influence of Fe2O3 Dust Particles on the Plasma Characteristics of D.C Sputtering System
...Show More Authors

    This work is an experimental study conducted to study the effects of iron oxide dust particles (Fe2O3) on the characteristics of DC discharge plasma in argon gas under vacuum. Electron temperature ( ) and electron density (ne) were calculated by Boltzmann plots and Stark broadening, respectively. The results show that both the electron density and plasma frequency ( ) increased with the operating pressure. While,  and Debye length ( ) decreased with pressure. The glow discharge is more stable with the Fe2O3-dust particles; all dust plasma parameters have lower values  than those of the dust-free plasma.

View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Tue Sep 01 2020
Journal Name
Clinical Plasma Medicine
Breast cancer treatment using cold atmospheric plasma generated by the FE-DBD scheme
...Show More Authors

Background Cold atmospheric plasma (CAP) is widely used in the cancer therapy field. This type of plasma is very close to room temperature. This paper illustrates the effects of CAP on breast cancer tissues both in vivo and in vitro. Methods The mouse mammary adenocarcinoma cell line AN3 was used for the in vivo study, and the MCF7, AMJ13, AMN3, and HBL cell lines were used for the in vitro study. A floating electrode-dielectric barrier discharge (FE-DBD) system was used. The cold plasma produced by the device was tested against breast cancer cells. Results The induced cytotoxicity percentages were 61.7%, 68% and 58.07% for the MCF7, AMN3, and AMJ13 cell lines, respectively, whereas the normal breast tissue HBL cell line exhibited very li

... Show More
View Publication
Scopus (35)
Crossref (34)
Scopus Clarivate Crossref
Publication Date
Tue May 30 2023
Journal Name
Iraqi Journal Of Science
Effect of Fe2O3 Nanoparticles Dust on the D.C Plasma Characteristics with Mirror Magnetron
...Show More Authors

     In this paper, the effect of iron oxide nanoparticles dust (Fe2O3 NPs) on the parameters of DC electric discharge plasma under vacuum in argon gas was studied with the presence of a mirror magnetron behind the electrodes (cathode and anode) at constant pressure and with different amounts of Fe2O3 nanoparticles. Calculations presented a reduction of the plasma emission intensity with the NPs content. Both the plasma density (calculated by Stark's broadening method) and the mean electron temperature (calculated using Boltzmann's equation) decreased with increasing the Fe2O3 nanoparticles dust content, which indicates clearly the effect of dust density on restricting

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Apr 27 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Theoretical Calculations For Sputtering Yield of Nickel Surface Hitted By Xenon Plasma Ions
...Show More Authors

Extended calculations for sputtering yield through bombed Nickel – target by Xenon ions plasma are accomplished. The calculations include changing the input parameters: the energy of xenon ions plasma, the hit target angle of nickel target, thickness of the nickel target layer, and the slight change in the surface binding energy of Nickel. The program TRIM is used to accomplish these calculations. The results show that the sputtering yields directly dependent on these parameters. The change in angles of incidence plasma ions and energy leads to a significant change in the sputtering yields. On the other hand, the sputtering yields ore highly affected by changing target width and surface binding energy at fixed ion parameters.

... Show More
View Publication Preview PDF
Publication Date
Thu Nov 05 2015
Journal Name
Spectroscopy Europe
Fast and versatile ambient surface analysis by plasmaassisted desorption/ionisation mass spectrometry
...Show More Authors

has experienced a step-change since the inception of ambient mass spectrometry removed the requirement for samples to be investigated under vacuum conditions. Approaches based on surface– plasma interactions are especially promising, including PADI. Whilst the mechanisms involved in generating PADI spectra still need to be unravelled, PADI shows significant promise to become a valuable and versatile tool in the instrumental arsenal available to the surface analyst