Preferred Language
Articles
/
nBdvMI8BVTCNdQwCql_M
Improving Surface Properties of PEEK for Dental Applications by Using Piranha Solution
...Show More Authors

Background. “Polyetheretherketone (PEEK)” is a biocompatible, high-strength polymer that is well-suited for use in dental applications due to its unique properties. However, achieving good adhesion between PEEK and hydrophilic materials such as dental adhesives or cement can be challenging. Also, this hydrophobicity may affect the use of PEEK as an implant material. Surface treatment or conditioning is often necessary to improve surface properties. The piranha solution is the treatment of choice to be explored for this purpose. Methods. PEEK disks of 10 mm diameter and 2 mm thickness were used in this study. Those samples were divided into five groups (each group has five samples). The first is the control group, in which no acid treatment was used; the second group undergoes sulfuric acid treatment. The remaining three groups were treated with Piranha solution; each group used a different concentration (1 : 3, 1 : 5, and 1 : 7 hydrogen peroxide to sulfuric acid, respectively). The period of treatment was 60 s for all groups. Wettability and surface roughness tests were done for the five groups. In statistical analysis, Shapiro–Wilk test was used to check the assumption of normality and to determine the statistical significance among groups; a one-way analysis of variance was employed. Subsequently, for multiple comparisons, Tukey’s honestly significant difference post hoc test was performed. Results. The Piranha solution treatment groups showed a higher wettability compared to the control group and the group treated with sulfuric acid. Additionally, the Piranha solution treatment with a higher concentration of hydrogen peroxide (1 : 3) resulted in greater improvement in surface roughness compared to the control group and the lower concentration groups (1 : 5 and 1 : 7), while the sulfuric acid treated group showed the highest surface roughness. Conclusion. The results of this study suggest that the piranha solution can be an effective method for improving the surface characteristics of PEEK to be used in different dental applications, especially as a dental implant material, due to the increase in wettability and surface roughness.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Effect of leaves extract of Adhatoda vasicia plant against some wounds contamining bacteria by using sensitive test
...Show More Authors

This study has been done on plant [Adhatoda vasicia , Acanthaceae family],which has been collected from gardens of university of Baghdad The leaves of plant were extracted by methanol alcohol obtain the crude extraction good ratio(30%).Eighty swabs or samples were collected from several wounds patients of hospitals in Baghdad city.These swabs were cultured on blood and MacConkey ager to isolate bacteria and identified by appearance and bio chemical tests.The results showed that(60)somples were positive(75%)for tests bacteria white the other(20)swabs were negative(25%).The bacteria were identified as Pseudomonas aeruginosa ,Staphylococcus awreus , Esherichia coli,Proteus spp and Klebsiella spp; and their number percentage were(32)isolates(

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 08 2022
Journal Name
V. International Scientific Congress Of Pure, Applied And Technological Sciences
The effect of background vacuum pressure on the length of gas discharge plasma by using Aluminum electrodes
...Show More Authors

Length of plasma generated by dc gas discharge under different vacuum pressures was studied experimentally. The cylindrical discharge tube of length 2m was evacuated under vacuum pressure range (0.1-0.5) mbar at constant external working dc voltage 1500V. It was found that the plasma length (L) increased exponentially with increasing of background vacuum air pressure. Empirical equation has been obtained between plasma length and gas pressure by using Logistic model of curve fitting. As vacuum pressure increases the plasma length increases due to collisions, ionizations, and diffusions of electrons and ions.

Publication Date
Mon Jun 01 2020
Journal Name
Journal Of Engineering
Studying the Microstructure of Al-Ti Alloy Prepared by Powder Metallurgy using Three Different Percentages of Ti
...Show More Authors

The effect of different Ti additions on the microstructure of Al-Ti alloy prepared by powder metallurgy was investigated. A certain amount of Ti (10wt%, 15wt%, and 20wt%) were added to aluminium and the tests like microhardness, density, scanning electron microscope (SEM), optical microscope (OM) and X-Ray Diffraction (XRD) were conducted to determine the influence of different Ti additives on the Al-Ti alloy properties and microstructure. The results show that the grains of α-Al changed from large grains to roughly spherical and then to small rounded grains with increasing Ti content, the micro-hardness of the alloy increases with increasing Ti, and XRD results confirm the formation of TiAl3 intermetallic co

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed May 10 2017
Journal Name
Journal Of The College Of Languages (jcl)
ФОРМИРОВАНИЕ КОММУНИКАТИВНО-РЕЧЕВОЙ КОМПЕТЕНЦИИ СТУДЕНТОВ КАФЕДРЫ Р The formation of verbal communication for students of Russian Language Department at College of Languages at University of Baghdad by using multiple technological means
...Show More Authors

В статье рассматривается вопрос об использовании мультимедийных средств для оптимизации процесса формирования коммуникативной компетенции  в иракской аудитории с привлечением компьютерных технологий. Статья посвящена  использованию мультимедийных технологий  и  различных  приемов формирования интереса к русскому языку. Включение в процесс обучения коммуникативно-значимого, аутентичн

... Show More
View Publication Preview PDF
Publication Date
Mon Apr 20 2020
Journal Name
Neuroquantology
The Role of Water Absorption on Thermal Conductivity and Mechanical Properties for (Recycling HDPE-Coal Ash) Composite
...Show More Authors

View Publication
Scopus (7)
Crossref (1)
Scopus Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Iraqi Journal Of Physics
Comparative study of the linear and nonlinear optical properties for different Iraqi heavy and light crude oils
...Show More Authors

Iraqi oil crudes have some of the physical and chemical characteristics that distinguish it from other types of oil crudes in the world. Some of these features such us molecular composition, rheological, viscosity and emulsions are studied carefully by researchers. In this work, a comparative study of the linear and the non-linear optical properties for typical heavy and light crude oils of Iraqi origin was studied utilizing Z-scan technique. The He -Ne laser of wavelength 632.8 nm had been used for this purpose. These samples were collected from Basra and Kut oil fields. The values of the non-linear refractive index (n2), non-linear absorption coefficient (β), and third-order electrical susceptibility (χ3) were e

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 18 2021
Journal Name
Energy & Fuels
Synergistic Effect of Nanoparticles and Polymers on the Rheological Properties of Injection Fluids: Implications for Enhanced Oil Recovery
...Show More Authors

New nanotechnology-based approaches are increasingly being investigated for enhanced oil recovery (EOR), with a particular focus on heavy oil reservoirs. Typically, the addition of a polymer to an injection fluid advances the sweep efficiency and mobility ratio of the fluid and leads to a higher crude oil recovery rate. However, harsh reservoir conditions, including high formation salinity and temperature, can limit the performance of such polymer fluids. Recently, nanofluids, that is, dispersions of nanoparticles (NPs) in a base fluid, have been recommended as EOR fluids; however, such nanofluids are unstable, even under ambient conditions. In this work, a combination of ZrO2 NPs and the polyacrylamide (PAM) polymer (ZrO2 NPs–PAM) was us

... Show More
Scopus (80)
Crossref (79)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of Mechanical Engineering Research And Developments
Effect of the shot peening surface treatment on the corrosion behavior of 2024-T3 aluminum alloy
...Show More Authors

Preview PDF
Scopus (2)
Scopus
Publication Date
Thu Jan 07 2021
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Effect of Dentifrices with Different Abrasives on the Surface Roughness of a Nano Composite Resins materials
...Show More Authors

Background: to evaluate the effect of different dentifrices on the surface roughness of two composite resins (nanofilled-based and nanoceramic – based composite resins). Materials and methods: Forty specimens (diameter 12 mm and height of 2mm) prepared from different composite resin materials: Z350 (nanofilled composite, and Ceram-X (nanoceramic) .they were subjected to brushing simulation equivalent to the period of 1 year. The groups assessed were a control group brushed with distilled water (G1), Opalescence whitening toothpasteR (G2), Colgate sensitive pro-relief (G3) and Biomed Charcoal Toothpaste (G4). The initial and final roughness of each group was tested by surface roughness tester. The results were statistically analyzed using

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sun Jan 25 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of shear bond strength of zirconia to tooth structure after different zirconia surface treatment techniques
...Show More Authors

Background: This study aimed to evaluate the effect of zirconia different surface treatments (primer, sandblast with 50μmAl2O3, Er,Cr:YSGG laser) on shear bond strength between zirconia surface and resin cement. Material and methods: Sixty presintered Y-TZP zirconia cylinder specimens (IPS e.max ZirCAD, Ivoclar vivadent) will be fabricated and sintered in high temperature furnace of (1500 C for 8 hours) according to manufacturer’s instructions to the selected size and shape of (5mm. in diameter and 6mm in height). All specimens were ground flat using 600.800.1000.1200, aluminum oxide abrasive paper to obtain a standardized surface roughness. Surface roughness values were then recorded in µm using surface roughness tester (profi

... Show More
View Publication Preview PDF