A simple, fast, selective of a new flow injection analysis method coupled with potentiometric detection was used to determine vitamin B1 in pharmaceutical formulations via the prepared new selective membranes. Two electrodes were constructed for the determination of vitamin B1 based on the ion-pair vitamin B1-phosphotungestic acid (B1-PTA) in a poly (vinyl chloride) supported with a plasticized di-butyl phthalate (DBPH) and di-butyl phosphate (DBP). Applications of these ion selective electrodes for the determination of vitamin B1 in the pharmaceutical preparations for batch and flow injection systems were described. The ion selective membrane exhibited a near-Nernstian slope values 56.88 and 58.53 mV / decade, with the linear dy
... Show MoreIn this paper the use of a circular array antenna with adaptive system in conjunction with modified Linearly Constrained Minimum Variance Beam forming (LCMVB) algorithm is proposed to meet the requirement of Angle of Arrival (AOA) estimation in 2-D as well as the Signal to Noise Ratio (SNR) of estimated sources (Three Dimensional 3-D estimation), rather than interference cancelation as it is used for. The proposed system was simulated, tested and compared with the modified Multiple Signal Classification (MUSIC) technique for 2-D estimation. The results show the system has exhibited astonishing results for simultaneously estimating 3-D parameters with accuracy approximately equivalent to the MUSIC technique (for estimating elevation and a
... Show MoreAlthough the Wiener filtering is the optimal tradeoff of inverse filtering and noise smoothing, in the case when the blurring filter is singular, the Wiener filtering actually amplify the noise. This suggests that a denoising step is needed to remove the amplified noise .Wavelet-based denoising scheme provides a natural technique for this purpose .
In this paper a new image restoration scheme is proposed, the scheme contains two separate steps : Fourier-domain inverse filtering and wavelet-domain image denoising. The first stage is Wiener filtering of the input image , the filtered image is inputted to adaptive threshold wavelet
... Show MoreIn this paper, a new method of selection variables is presented to select some essential variables from large datasets. The new model is a modified version of the Elastic Net model. The modified Elastic Net variable selection model has been summarized in an algorithm. It is applied for Leukemia dataset that has 3051 variables (genes) and 72 samples. In reality, working with this kind of dataset is not accessible due to its large size. The modified model is compared to some standard variable selection methods. Perfect classification is achieved by applying the modified Elastic Net model because it has the best performance. All the calculations that have been done for this paper are in
The denoising of a natural image corrupted by Gaussian noise is a problem in signal or image processing. Much work has been done in the field of wavelet thresholding but most of it was focused on statistical modeling of wavelet coefficients and the optimal choice of thresholds. This paper describes a new method for the suppression of noise in image by fusing the stationary wavelet denoising technique with adaptive wiener filter. The wiener filter is applied to the reconstructed image for the approximation coefficients only, while the thresholding technique is applied to the details coefficients of the transform, then get the final denoised image is obtained by combining the two results. The proposed method was applied by usin
... Show MoreAbstract: The aim of the current study was to investigate the possible protective effect of graded doses (5, 10, and 15mg/kg) of pyridoxine hydrochloride intraperitoneally injected against (15mg/kg) doxorubicin-induced cardiotoxicity in female rats. Fifty-six (56) Wistar albino female rats were utilized weighing 180-200 gm allocated into eight groups, seven rats each; Group I: negative control distilled water; Group II: Pyridoxine (5mg/kg); Group III: Pyridoxine (10mg/kg); Group IV: Pyridoxine (15mg/kg); Group V: doxorubicin (15 mg/kg); Group VI: Pyridoxine (5 mg/kg) prior to doxorubicin (15 mg/kg); Group VII: Pyridoxine (10 mg/kg) prior to doxorubicin (15 mg/kg); Group VIII: Pyridoxine (15 mg/kg) prior to doxorub
... Show MoreIn this work, p-n junctions were fabricated from highly-pure nanostructured NiO and TiO2 thin films deposited on glass substrates by dc reactive magnetron sputtering technique. The structural characterization showed that the prepared multilayer NiO/TiO2 thin film structures were highly pure as no traces for other compounds than NiO and TiO2 were observed. It was found that the absorption of NiO-on-TiO2 structure is higher than that of the TiO2-on-NiO. Also, the NiO/TiO2 heterojunctions exhibit typical electrical characteristics, higher ideality factor and better spectral responsivity when compared to those fabricated from the same materials by the same technique and with larger particle size and lower structural purity.