Air pollution from various sources is one of the most serious environmental problems, especially after pollutants are deposited on the surface of the soil and leaves of the plants and then transferred to the rest of the plant and entering food chains. The present study was conducted to determine the effects of air pollution on different biochemical parameters in Eucalyptus sp. and calculation the Air Pollution Tolerance Index. The selected plant leaves were collected from five sites, four of them within the city of Baghdad, namely Al-Jadriya, Al-Andlous, Al-Doura and close to the private generators to represent the urban areas and Abu Ghraib site to represent the rural area. The leaves were taken on a seasonal basis for the period from Octo
... Show MoreThe phenomenon of young people frequenting closed cafes spread in Baghdad to smoke hookahs and cigarettes has increased. This phenomenon is associated with unemployment, an increase in leisure time and the deterioration of economic conditions. This phenomenon has an impact on indoor air quality and exposes workers to the risk of exposure to various pollutants, including particulate matter, therefore, we examined some indicators (PM2.5, PM10) IAQ for a month in summer and another month in winter in six different locations in the Rusafa district. PM2.5 and PM10 concentrations, relative humidity (RH) and temperatures were measured using (Multifunction Air Quality Detector BENETECH -China). The results showed an increase in temperatures inside
... Show MoreExperimental and numerical studies have been conducted for the effect of injected air bubbles on the heat transfer coefficient through the water flow in a vertical pipe under the influence of uniform heat flux. The investigated parameters were water flow rate of (10, 14 and 18) lit/min, air flow rate of (1.5, 3 and 4) lit/min for subjected heat fluxes of (27264, 36316 and 45398) W/m2. The energy, momentum and continuity equations were solved numerically to describe the motion of flow. Turbulence models k-ε was implemented. The mathematical model is using a CFD code Fluent (Ansys15). The water was used as continuous phase while the air was represented as dispersed. phase. The experimental work includes design, build and instrument a test
... Show MoreThe behavior and shear strength of full-scale (T-section) reinforced concrete deep beams, designed according to the strut-and-tie approach of ACI Code-19 specifications, with various large web openings were investigated in this paper. A total of 7 deep beam specimens with identical shear span-to-depth ratios have been tested under mid-span concentrated load applied monotonically until beam failure. The main variables studied were the effects of width and depth of the web openings on deep beam performance. Experimental data results were calibrated with the strut-and-tie approach, adopted by ACI 318-19 code for the design of deep beams. The provided strut-and-tie design model in ACI 318-19 code provision was assessed and found to be u
... Show MoreThe CIGS/CdS p-n junction thin films were fabricated and deposited at room temperature with rate of deposition 5, and 6 nm secG1 , on ITO glass substrates with 1mm thickness by thermal evaporation technique at high vacuum pressure 2×10G5 mbar, with area of 1 cm2 and Aluminum electrode as back contact. The thickness of absorber layer (CIGS) was 1 µm while the thickness of the window layer CdS film was 300 nm. The X-ray Diffraction results have shown that all thin films were polycrystalline with orientation of 112 and 211 for CIGS thin films and 111 for CdS films. The direct energy gaps for CIGS and CdS thin films were 1.85 and 2.4 eV, respectively. Atomic Force Microscopy measurement proves that both films CIGS and CdS films have nanostru
... Show MorePV connected systems are worldwide installed because it allows consumer to reduce energy consumption from the electricity grid. This paper presents the results obtained from monitoring a 1.1 kWp. The system was monitored for nine months and all the electricity generated was fed to the fifth floor for physics and renewable energy building 220 V, 50 Hz. Monthly, and daily performance parameters of the PV system are evaluated which include: average generated of system Ah per day, average system efficiency, solar irradiation around these months. The average generated kWh per day was 8 kWh/day, the average solar irradiation per day was 5.6 kWh/m2/day, the average inverter efficiency was 95%, the average modules efficien
... Show MoreThe research aims to study the entrepreneurial performance of the banks, according to the intelligence of competitive and strategic as the entrepreneurial performance is the one who does not stand the benefits of excellence in accomplished when just achieving the bank's objectives planned, but exceed it down to creativity in accomplishing these goals in a manner leads to making a entrepreneurial bank in the markets and the focus the eyes of competitors and the banks and other Following his example.
Was chosen the subject of research and strategic intelligence and competitive because of its impact on the strategic success of the banking sector, the fact is the entrepreneurial in the Iraqi banking mar
... Show MoreThis paper is devoted to investigate the effect of internal curing technique on the properties of self-compacting concrete (SCC). In this study, SCC is produced by using silica fume (SF) as partial replacement by weight of cement with percentage of (5%), sand is partially replaced by volume with saturated fine lightweight aggregate (LWA) which is thermostone chips as internal curing material in three percentages of (5%, 10% and 15%) for SCC, two external curing conditions water and air. The experimental work was divided into three parts: in the first part, the workability tests of fresh SCC were conducted. The second part included conducting compressive strength test and modulus of rupture test at ages of (7, 28 and 90). The third part i
... Show More