Preferred Language
Articles
/
mBZTZ4cBVTCNdQwC1kmc
Determination of time-dependent coefficient in time fractional heat equation
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Thu Dec 22 2022
Journal Name
Chemistry & Chemical Technology
Turbidimetric Determination of Mebeverine Hydrochloride in Pharmaceutical Formulations Using Two Consecutive Detection Zones under Continuous Flow Conditions
...Show More Authors

A simple, low cost and rapid flow injection turbidimetric method was developed and validated for mebeverine hydrochloride (MBH) determination in pharmaceutical preparations. The developed method is based on forming of a white, turbid ion-pair product as a result of a reaction between the MBH and sodium persulfate in a closed flow injection system where the sodium persulfate is used as precipitation reagent. The turbidity of the formed complex was measured at the detection angle of 180° (attenuated detection) using NAG dual&Solo (0-180°) detector which contained dual detections zones (i.e., measuring cells 1 & 2). The increase in the turbidity of the complex was directly proportional to the increase of the MBH concentration

... Show More
View Publication
Scopus (11)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Baghdad Science Journal
Simultaneous Determination of Piroxicam and Codeine Phosphate Hemihydrate in a Pharmaceutical Dosage Form Using Validated HPLC Method
...Show More Authors

An easy, eclectic, precise high-Performance Liquid Chromatographic (HPLC) procedure was evolved and validated to estimate of Piroxicam and Codeine phosphate. Chromatographic demarcation was accomplished on a C18 column [Use BDS Hypersil C18, 5μ, 150 x 4.6 mm] using a mobile phase of methanol: phosphate buffer (60:40, v/v, pH=2.3), the flow rate was 1.1 mL/min, UV detection was at 214 nm. System Suitability tests (SSTs) are typically performed to assess the suitability and effectiveness of the entire chromatography system. The retention time for Piroxicam was found to be 3.95 minutes and 1.46 minutes for Codeine phosphate. The evolved method has been validated through precision, limit of quantitation, specificity,

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jul 01 2012
Journal Name
Food Chemistry
High performance liquid chromatographic determination of aflatoxins in chilli, peanut and rice using silica based monolithic column
...Show More Authors

A simple and rapid high performance liquid chromatographic with fluorescence detection method for the determination of the aflatoxin B1, B2, G1 and G2 in peanuts, rice and chilli was developed. The sample was extracted using acetonitrile:water (90:10, v/v%) and then purified by using ISOLUTE multimode solid phase extraction. After the pre-column derivatisation, the analytes were separated within 3.7 min using Chromolith performance RP-18e (100–4.6 mm) monolithic column. To assess the possible effects of endogenous components in the food items, matrix-matched calibration was used for the quantification and validation. The recoveries of aflatoxins that were spiked into food samples were 86.38–104.5% and RSDs were <4.4%. The method was

... Show More
View Publication
Scopus (89)
Crossref (80)
Scopus Clarivate Crossref
Publication Date
Thu Mar 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
The Role of Cone Beam Computed Tomography in Determination of the Greater Palatine Foramen Position Among Iraqi Population
...Show More Authors

Background: The use of the cone beam computed tomography for analysing the position of the greater palatine foramen in relation to various anatomical landmarks is crucial in dentistry. The aims of the current study, firstly is to determine the greater palatine foramen position in relation to various anatomical landmarks by using cone beam computed tomography and secondly is to make a comparison of the measurements according to side, gender, and age. Materials and methods: This prospective study included 60 Iraqi patients (28males and 32 females) who selected according to availability of Inclusion criteria, which include age range (21 - 60 years), with no dentofacial deformities or pathological lesion at the maxilla. All patients had inform

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Baghdad Science Journal
Determination of fungal and parasitic infections caused vaginitis: molecular identification of Candida parapsilosis in Al-Nasiriyah city, Iraq
...Show More Authors

The current study aims to determine the prevalence of Trichomonas vaginalis and Candida spp., and also to identify Candida parapsilosis and some virulence genes. It was conducted in Bint Al-Hoda Hospital of Maternity and Children in Thi-Qar province, south of Iraq for the period from the beginning of January to the end of December 2020. Two hundred and fifty samples were collected from the female genital tract for women whose age ranged between 17-50 years. Microscopic, traditional and molecular tests were used in the sample examination. The results recorded 12 (4.8%) samples infected with T. vaginalis parasite, whereas 130 (52%) samples showed Candida yeast distributed as follows: 75 (30 %) <

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Analytical Potentiality of Computer - Controlled Background Correction with Electrothermal Atomic Emission Spectrometry : Determination of Copper in Milk Powder
...Show More Authors

A fully automatic electrothermal atomic emission spectrometry (ETA-AES) is described. This system is based on an echelle monochromator modified for wave¬length modulation which is completely controlled by microcomputer . The advantages of the system in atomic spectrometry have been discussed . Aspects of the analytical performances such as calibration ? dection limit, precision , and recovery for copper are considered . This system is applied for routine determination of copper in commercial powdered mill? by slurr>' atomization versus aqueous atomization techniques.

View Publication Preview PDF
Publication Date
Sat Jun 30 2018
Journal Name
International Journal Of Medical Research & Health Sciences
Assessment of the Healthy Women by Detection and Determination of Cells in Conventional Pap Stained Cervical Smear Images
...Show More Authors

Introduction: A Pap test can detect pre-cancerous and cancerous cells in the vagina and uterine cervix. Cervical cancer is the easiest gynecologic cancer to be prevented and diagnosed using regular screening tests and follow-up. This study aimed to estimate the cytological changes and the precancerous lesions using Pap smear test and visual inspection of the cervices of Iraqi women, and also to determine the possible relationship of this cancer with patients’ demographic characteristics. Methods: The study included 140 women aged (18-67) years old referred to the National Cancer Research Center (NCRC), Baghdad, Iraq, during the period 2011-2016. Both visual inspections of the uterine cervix and Papanicolaou smear screening were performed

... Show More
Preview PDF
Publication Date
Tue Dec 31 2019
Journal Name
Biochemical & Cellular Archives
DETERMINATION OF MYELOPEROXIDASE, HOMOCYSTEINE AND RELATED OTHER PARAMETERS WITH YOUNG SMOKERS OF CIGARETTE AND NARGHILE IN BAGHDAD CITY
...Show More Authors

Smoking is the inhalation of smoke tobacco burning that cover with narghile and cigarettes. There are a many problems result smoking such as, deterioration of health in general, undesirable social phenomenon, waste of money and time and stress.This study design to identify the effects of smoking narghile and cigarettes on levels of MPO, HCY and lipidprofil via determination of those parameters in cohort younger of Baghdad city. So to found the correlation coefficient of MPO and those parameters in groups that smoking cigarette and narghiledaily.As well as, to consider the MPO as biomarker to predictor coronary heart diseases. Increased levels of MPO, HCY total cholesterol (TC), triglyceride (TG), very low-density lipoprotein (VLDL) and low-

... Show More
Scopus (1)
Scopus
Publication Date
Mon Jan 06 2020
Journal Name
Plant Archives
ROLE OF ANALYTICAL CHEMISTRY FOR THE DETERMINATION OF ASCORBIC ACID: A REVIEW
...Show More Authors

Vitamins play an important role in the human health, and thus they are the kind of major nutrients in the body. Chemical products perform numerous physiological functions and can jeopardize health jointly in their absence and surplus. Therefore, it is necessary to establish methods for observation vitamin levels in various molds. In this review paper, the most methods of determination used are high performance liquid chromatography (HPLC), spectrophotometric and potentiometric techniques by listed the value of : slope, linear range, correlation coefficient, detection limit, the max of wavelength and PH and compared with these methods.

Publication Date
Tue Sep 01 2020
Journal Name
Journal Of Engineering
Experimental and Theoretical Determination of Settlement of Shallow Footing on Liquefiable Soil
...Show More Authors

A high settlement may take place in shallow footing when resting on liquefiable soil if subjected to earthquake loading. In this study, a series of shaking table tests were carried out for shallow footing resting on sand soil. The input motion is three earthquake loadings (0.05g, 0.1g, and 0.2g). The study includes a reviewing of theoretical equations (available in literatures), which estimating settlement of footings due to earthquake loading, calibration, and verification of these equations with data from the shaking table test for improved soil by grouting and unimproved soil. It is worthy to note that the grouting materials considered in this study are the Bentonite and CKD slurries. A modification to the seismic set

... Show More
View Publication Preview PDF
Crossref (7)
Crossref