Experimental investigation for small horizontal portable wind turbine (SHPWT) of NACA-44, BP-44, and NACA-63, BP-63 profiles under laboratory conditions at different wind velocity range of (3.7-5.8 m/s) achieved in present work. Experimental data tabulated for 2, 3, 4, and 6- bladed rotor of both profiles within range of blade pitch angles . A mathematical model formulated and computer Code for MATLAB software developed. The least-squares regression is used to fit experimental data. As the majority of previous works have been presented for large scale wind turbines, the aims were to present the performance of (SHPWT) and also to make a comparisons between both profiles to conclude which is the best performance. The overall efficiency and electrical output power affected by changing blades number and . The best for both profiles of 2 and 3-bladed rotor occurred at and NACA-44, BP-44 profile was better than NACA-63, BP-63 profile. The best for both profiles of 4-bladed rotor occurred at , and NACA-63, BP-63 profile was better than NACA-44, BP-44 profile. The best of 6-bladed rotor occurred at for NACA-44, BP-44 profile and at for NACA-63, BP-63 profile, clearly NACA-44, BP-44 profile was better than NACA-63, BP-63 profile. Finally, the maximum value of mean overall efficiency was concluded for NACA-44, BP-44 profile of 6-bladed rotor at .
Due to a party's violation of his obligations or responsibilities indicated in the contract, many engineering projects confront extensive contractual disputes, which in turn need arbitration or other forms of dispute resolution, which negatively impact the project's outcome. Each contract has its terms for dispute resolution. Therefore, this paper aims to study the provisions for dispute resolution according to Iraqi (SBDW) and the JCT (SBC/Q2016) and also to show the extent of the difference between the two contracts in the application of these provisions. The methodology includes a detailed study of the dispute settlement provisions for both contracts with a comparative analysis to identify the differences in the appli
... Show MoreObjectives This work presents laser coating of grade 1 pure titanium (Ti) dental implant surface with sintered biological apatite beta-tricalcium phosphate (β-TCP), which has a chemical composition close to bone. Materials and methods Pulsed Nd:YAG laser of single pulse capability up to 70 J/10 ms and pulse peak power of 8 kW was used to implement the task. Laser pulse peak power, pulse duration, repetition rate and scanning speed were modulated to achieve the most homogenous, cohesive and highly adherent coat layer. Scanning electron microscopy (SEM), energy dispersive X-ray microscopy (EDX), optical microscopy and nanoindentation analyses were conducted to characterise and evaluate the microstructure, phases, modulus of elasticity
... Show MoreIn this article, the casting method was used to prepare poly(methyl methacrylate)/hydroxyapatite (PMMA/HA) nanocomposite films incorporated with different contents (0.5, 1, and 1.5 wt%) of graphene nanoplatelets (Gnp). The chemical properties and surface morphology of the PMMA/HA blend and PMMA/HA/Gnp nanocomposite were characterized using FTIR, and SEM analysis. Besides, the thermal conductivity, dielectric and electrical properties at (1–107 Hz) of the PMMA/HA blend and PMMA/HA/Gnp composites were investigated. The structural analysis showed that the synthesized composites had a low agglomerated state, with multiple wrinkles of graphene flakes in the PMMA/HA blend. The thermal conductivity was improved by more than 35-fold its value for
... Show MoreThis study presents a novel, custom‑built fluorescence detector for the precise determination of chloride and iodide ions based on their quenching effect on fluorescein. The detection system incorporates eight blue LEDs irradiation sources arranged at 0–90° angles relative to twin solar cell detectors connected. Two fluorescence quenching strategies were developed. The injected‑mixture mode (IMFQ) exhibited linear ranges of 0.00–1.00 mM for Cl⁻ and 0.00–1.25 mM for I⁻, with detection limits of 20 µM and 10 µmol L⁻¹, respectively. The continuous‑flow mode (CFFQ) demonstrated superior sensitivity with a dispersion factor of 1.33, wider linear ranges (0.1–6.0 m
Protection study of the corrosion behavior of Copper surface was conducted with several concentrations of drug. Experimentally, voltammetric measurements were used to check the inhibition efficiency (% IE) in saline solution of 3.5% NaCl. The results showed an increase in the inhibition efficiency with increasing the concentration of the drug was 95.90%. Theoretical treatment of the drug in the gas phase was performed using the (hyperchem-8.07) program for molecular mechanics and semi-empirical computations. The (PM3) approach was used to determine the heat of formation (1H˚f), binding energy (1Eb), and total energy (ET