We propose a new method for detecting the abnormality in cerebral tissues present within Magnetic Resonance Images (MRI). Present classifier is comprised of cerebral tissue extraction, image division into angular and distance span vectors, acquirement of four features for each portion and classification to ascertain the abnormality location. The threshold value and region of interest are discerned using operator input and Otsu algorithm. Novel brain slices image division is introduced via angular and distance span vectors of sizes 24˚ with 15 pixels. Rotation invariance of the angular span vector is determined. An automatic image categorization into normal and abnormal brain tissues is performed using Support Vector Machine (SVM). Standard Deviation, Mean, Energy and Entropy are extorted using the histogram approach for each merger space. These features are found to be higher in occurrence in the tumor region than the non-tumor one. MRI scans of the five brains with 60 slices from each are utilized for testing the proposed method’s authenticity. These brain images (230 slices as normal and 70 abnormal) are accessed from the Internet Brain Segmentation Repository (IBSR) dataset. 60% images for training and 40% for testing phase are used. Average classification accuracy as much as 98.02% (training) and 98.19% (testing) are achieved.
Numerical simulations were carried out to evaluate the effects of different aberrations modes on the performance of optical system, when observing and imaging the solar surface. Karhunen-Loeve aberrations modes were simulated as a wave front error in the aperture function of the optical system. To identify and apply the appropriate rectification that removes or reduces various types of aberration, their attribute must be firstly determined and quantitatively described. Wave aberration function is well suitable for this purpose because it fully characterizes the progressive effect of the optical system on the wave front passing through the aperture. The Karhunen-Loeve polynomials for circular aperture were used to
... Show MoreHeavy metal contamination comprises a great concern in the environment. A magnetic study combined with heavy metal analyses was performed in the Sawa Lake in Al-Muthanna governorate (southern Iraq). Concentrations of selected heavy metals (Cr, Fe, Ni, As and Pb) have been measured and magnetic susceptibility (χ) of sediment samples collected from the lake bottom was calculated.
The results confirmed that a cement plant, which is located less than two kilometers away from the lake has no contamination levels on the lake’s sediments. No enhancement in the magnetic susceptibility was observed. X-ray florescence (XRF) was performed for heavy metal analyses.
Spatial variations of χ with the mean value of 4.58 x
... Show MoreNotes are given regarding new record species of the braconid parasite short note in Iraq. That is Apanteles angalcti it is found to parasitize early larval instaxs of Ectomyslois ceratontae, one of the most serious pests of pomegra- nate fruit.
Saxifraga afghanica Aitch. & Hemsl. is a new addition to the Saxifragaceae family in Iraq, from Qandil mountain (north-east of Erbil) within Rowanduz district (MRO). The collected specimens have different characteristics. S. afghanica is perennial, herb, with crowded shoots forming cushions, many branched. Leaves sessil, narrowly oblong, narrowly oblong-lanceolate, oblanceolate or sub-spatulate, glabrous, entire, ciliated at lower half, apex leaves aggregated into a rosette, chalk glands (pits at the leaves apex) 5. Bracts cultrate, linear or narrowly oblong, glandular-pubescent. Inflorescence corymbose cyme, flowers (3-5), white-pink, stamens 10, ovary semi-inferior, styles 2, divergent, recurved at the top. Capsule globose-semi glo
... Show MoreIn this paper, a method for data encryption was proposed using two secret keys, where the first one is a matrix of XOR's and NOT's gates (XN key), whereas the second key is a binary matrix (KEYB) key. XN and KEYB are (m*n) matrices where m is equal to n. Furthermore this paper proposed a strategy to generate secret keys (KEYBs) using the concept of the LFSR method (Linear Feedback Shift Registers) depending on a secret start point (third secret key s-key). The proposed method will be named as X.K.N. (X.K.N) is a type of symmetric encryption and it will deal with the data as a set of blocks in its preprocessing and then encrypt the binary data in a case of stream cipher.
In this paper, the peristaltic flow under the impact of heat transfer, rotation and induced magnetic field of a two dimensional for the Bingham plastic fluid is discussed. The coupling among of momentum with rotational, energy and the induced magnetic field equations are achieved by the perturbation approximation method and the mathematica software to solve equations that are nonlinear partial differential equations. The fluid moves in an asymmetric channel, and assumption the long wavelength and low Reynolds number, approximation are used for deriving a solution of the flow. Expression of the axial velocity, temperature, pressure gradient, induced magnetic field, magnetic force, current density are developed the eff
... Show MoreIn this research, a sensor for chemical solutions was designed and formed using optical fiber-based on a surface Plasmon resonance technology. A single-mode optical fiber with three different diameters (25, 45 and 65) µm was used, respectively. The second layer of the low refractive fiber was replaced by gold, which was electrically deposited at 40 µm thickness. For each of the three types of optical fiber, different saline concentrations (different index of refraction) were used to evaluate the performance of the refractive index sensor (chemical sensor) by measuring its sensitivity and resolutions. The highest values we could get for these two parameters were 240mm/RIU, and 6*10-5 RIU respectively, when the diameter of a
... Show More