Pilot-scale dead end microfiltration membranes were carried out to determine the feasibility of the process for treating the oily wastewater which discharge from some Iraqi factories such as power station of south of Baghdad and the general company of petrochemical industries. Polypropylene membranes (cylindrical shape) with different pore diameters (1 and 5 micron) were used to conduct the study on micromembrane process. The variables studied are oil concentration (100 – 1000 ppm), feed flow rate (20 – 40 l/h), operating temperature (31 – 50°C) and time (0 – 3 h). It was found that the flux increases with increasing feed flow rate, temperature and pore size of membrane, and decreases with increasing oil concentration and operating time. It was found also that the effect of feed oil concentration has the greatest effect on the fouling of membrane among other variables. The percent rejection of oil improved significantly with decreasing oil concentration but decreased with increasing feed temperature, pore size of membrane and operating time. Feed flow rate has slightly effect on oil rejection. The type of oil used in this work is 20W-50 gasoline and diesel engine oil. A general model of dead end filtration mode has been successfully evaluated to explain fundamental mechanisms involved in flux decline during dead end microfiltration of oily water emulsions. Analysis of the fall in flux with time for the polypropylene membrane (5 µm) indicates that intermediate and standard pore models give the best prediction for experimental behavior. Empirical correlations for the prediction of the flux and percent reject of oil were determined in this study. These equations have the correlation coefficient 98.87% and 91.49% respectively.
Introduction: The therapeutic efficacy of erythropoietin (EPO) may be diminished by the formation of anti-erythropoietin antibodies (AEAs), potentially resulting in therapy failure. Objectives: This retrospective study included 84 hemodialysis patients with end-stage renal disease (ESRD) treated with recombinant EPO and aimed to evaluate the association between serum AEA and treatment response. Patients and Methods: This cross-sectional study included eighty-four Iraqi patients with ESRD who had been on recombinant human EPO for more than 6 months and had hemoglobin levels below 11 g/dL. Serum AEA levels were measured in all patients to evaluate their association with treatment response and to investigate correlations with demograph
... Show MoreNew metal complexes of the ligands 2-benzamido benzothiazole(B1), and 2-actamido benzothiazole(B2) with metal ions Ni(II),and Co(II) were prepared in alcoholic medium. The prepared complexes were characterized by FT-IR and electronic spectroscopy, Magnetic susceptibility, Flame Atomic Absorption technique as well as elemental analysis and conductivity measurement. From the spectral studies, an octahedral monomer structure proposed for Ni(II) complexes, and a tetrahedral monomer structure for Co(II)complexes.Semi-empirical methods (PM3,and ZINDO/1)were carried out to evaluate the heat formation( ?H?f)binding energy(?Eb) and dipole moment(µ)for all metal complexes. Also vibration frequencies, Electrostatic potential, HOMO and LUMO
... Show MoreKE Sharquie, AA Noaimi, AM Oweid, JSSDDS, 2009 - Cited by 2
Background: Oral anticoagulation medication, warfarin and non-vitamin k antagonist oral anticoagulants (NOAC) may require long term use which may affect patients’ satisfaction with their treatment and their quality of life (QOL). Objective: To compare the quality of life and treatment satisfaction among groups of patients using different anticoagulant therapies (warfarin and NOAC). Patients and methods: A cross-sectional study was performed at Ibn Al-Bitar Hospital for cardiac surgery in Baghdad in the period between December 2022 to May 2023. The study population included a convenient sample of patients receiving either warfarin or non-vitamin k antagonist oral anticoagulants treatment. The Arabic version of the short form 12
... Show MoreThis article discusses the function of semiotics in political discourse after the socio-political processes taking place in Iraq since 2003 and its role in the development of textual criticisms of some Iraqi politicians, analyzes the reasons for its functioning in the speech of politicians. The research is mainly focused on finding out to what extent political text studies draw on sign systems that can store and transmit information, the nature of its purpose and the use of available fields for the purpose to be achieved. The chief purpose of the study is to investigate and also clarify the symbols and signs appear within the framework of discursive Iraqi politicians, the nature of the symbols used, and the meanings that are include
... Show MoreBackground: This study aimed to examine the efficacy of methylene blue (MB) and toluidine blue O (TBO) photodynamic therapy (PDT) as adjuncts to root surface debridement (RSD). Methods: This split-mouth, randomized, controlled clinical trial included eighteen patients, and a total of 332 sites (control = 102, MB = 124 and TBO = 106) were examined. Two sessions of PDT were completed at baseline and two weeks after RSD. Clinical parameters of bleeding on probing (BOP), plaque index (PI), probing pocket depth (PPD), and clinical attachment level (CAL) were measured pre- and post-treatment. Results: PPD and BOP reductions in sites treated by RSD with adjunctive photosensitizers (MB and TBO) were significantly higher than in control site
... Show MoreIn this work, electrochemical process was presented to polymerized eugenol on Gr.2 and Gr.5 titanium alloys before and after treated by Micro Arc Oxidation (MAO), where Gr.2 is commercial pure titanium and Gr.5 is Ti-6Al-4V dental alloys. The deposited layers were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). The adhesion strength of polymeric thin-film was estimation by using pull-off adhesion test and the result was the adhesion strength of PE was (1.23 MPa) on Gr.2 before MAO and increase to (1.98 MPa) on Gr.2 after MAO treatment. The corrosion behavior of Gr.2 and Gr.5 alloy in artificial saliva environment at
... Show More