Preferred Language
Articles
/
lReuZ48BVTCNdQwCUnax
Improvement the surface properties of metal valves used in agriculture engine by using CO<inf>2</inf> laser beam
...Show More Authors

Scopus
Preview PDF
Quick Preview PDF
Publication Date
Wed Apr 05 2017
Journal Name
Journal Of Agriculture And Veterinary Science
Tillage Appearance Device Test When Used Mold Board Plow Under Difference of a Variables Condition
...Show More Authors

Tillage appearance device is mechanical, electric-electronic design, getting Patent from the Central Organization for Standardization and Quality Control – Industrial Property Department - Ministry of Planning – The Republic of IRAQ under number Patent 3876 in 20 / 4 / 2014, calculates the number of clods per area by Tillage appearance device, This is done through the generation electrical impulses are sent to the controlled accurate calculates number clods required space and shows the result on the screen in order to see the tillage view per area. Three factor used in these experiment, first factor represents forward speed of tractor three levels (3.5, 4.5, and 5.5 km/h), second factor represent soil moisture content at two levels (14

... Show More
Publication Date
Fri Jan 01 2021
Journal Name
Materials Today: Proceedings
Response surface methodology: A review on its applications and challenges in microbial cultures
...Show More Authors

View Publication
Scopus (213)
Crossref (163)
Scopus Clarivate Crossref
Publication Date
Wed Jun 01 2016
Journal Name
Journal Of Engineering
A Novel Analytical Model to Design Piezoelectric Patches Used to Repair Cracked Beams
...Show More Authors

In this paper, an analytical solution describing the deflection of a cracked beam repaired with piezoelectric patch is introduced. The solution is derived using perturbation method. A novel analytical model to calculate the proper dimensions of piezoelectric patches used to repair cracked beams is also introduced. This model shows that the thickness of the piezoelectric patch depends mainly on the thickness of the cracked beam, the electro-mechanical properties of the patch material, the applied load and the crack location. Furthermore, the model shows that the length of the piezoelectric patches depends on the thickness of the patch as well as it depends on the length of the cracked beam and the crack depth. The additional flexibil

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Wed Jun 01 2016
Journal Name
Journal Of Engineering
A Novel Analytical Model to Design Piezoelectric Patches Used to Repair Cracked Beams
...Show More Authors

In this paper, an analytical solution describing the deflection of a cracked beam repaired with piezoelectric patch is introduced. The solution is derived using perturbation method. A novel analytical model to calculate the proper dimensions of piezoelectric patches used to repair cracked beams is also introduced. This model shows that the thickness of the piezoelectric patch depends mainly on the thickness of the cracked beam, the electro-mechanical properties of the patch material, the applied load and the crack location. Furthermore, the model shows that the length of the piezoelectric patches depends on the thickness of the patch as well as it depends on the length of the cracked beam and the crack depth. The additio

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 14 2016
Journal Name
Euphrates Journal Of Agricultural Science
A field compare five horticulture machines when used normal and super Iraqi fuel
...Show More Authors

A field Experiment was carried out in Baghdad for the purpose of compare five horticulture machines during used two types of fuel deffirance in octane number, normal and super fuel which produced in Iraqi and measuring the vibrations transmitted of the three axes are longitudinal X , lateral Y and vertical Z from handlebar in (Mowers) to the operator which walks behind the mower, and the determine of the productivity practical of cutting, productivity passing and fuel consumption. Experiment Factorial used with two factors, The first factor was Five Mowers vary in width , types, weight and company manufacturer, The Second factor was the types of fuel used internal combination engine horticulture mowers were Normal fuel with Octane Number 82

... Show More
Publication Date
Tue Sep 01 2020
Journal Name
Baghdad Science Journal
Decolorization of Phenol Red Dye by Immobilized Laccase in Chitosan Beads Using Laccase - Mediator - System Model
...Show More Authors

This work describes the enhancement of phenol red decolorization through immobilizing of laccase in chitosan and enzyme recycling. Commercial laccase from white rot fungus, Trametesversicolor (Tvlac), was immobilizedin to freshly prepared chitosan beads by using glutaraldehyde as a cross linker. Characterization of prepared chitosan was confirmed by FTIR and scanning electron microscope (SEM). Tvlac (46.2 U/mL) immobilized into chitosan beads at 0.8 % glutaraldehyde (v/v) within 24 hrs. Synthetic (HBT) and natural (vanillin) mediators were used to enhance dye decolorizoation. It was found that 89 % of phenol red was decolorized by chitosan beads within 180 min. in the absence of enzyme and mediator, while decolorization percenta

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Evaluation of Trace Elements in Iraqi Patients with Rheumatoid Arthritis by using Atomic Absorption Spectrophotometer (AAS)
...Show More Authors

Zinc, Copper, Selenium, Magnesium, Manganese, Chromium, Iron, Nickel, Cobalt, Vanadium and Germanium were determined by atomic absorption spectrophotometer (AAS) in blood serum of patients with rheumatoid arthritis, (30) patients (14male and 16female) with age range (37-60) years compared with normal tensive control. The analysis of results showed that the mean value of concentration (Magnesium,  Manganese and Nickel) were significantly higher in patients with rheumatoid arthritis compared to that of healthy, while the mean levels of serum (Zinc, Copper, Selenium, Chromium, Iron, Cobalt and Germanium) were significantly lower than controls. There were no significant changes in overall mean concentration of serum Vanadium in patients

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Dec 04 2011
Journal Name
Baghdad Science Journal
Determination of Antibodies (IgG, IgM) against Toxoplasma gondii in Some Iraqi individuals by using ELISA technique
...Show More Authors

A total of 258 voluntary blood donors (males 101; females 157) in the age range of 18-52 yr among males and 18-55 yr among females were examined for Toxoplasma gondii antibodies (IgG), and (IgM) by immunological technique (Enzyme linked Immunosorbant Assay) during the period from March 2009 to April 2010. This study covered a wide range of factors including immunological, age ,sex , place of residence and symptoms that may have a possible relationship with toxoplasmosis. Results presented in this study showed clearly that 38 (14.7%) of individuals participated in this study having IgG Toxoplasma Ab, among those 10 samples (9.9%) were males and 28 samples (17.8%) were females. Moreover, we found the prevalence of IgM seropositivity in th

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed Oct 12 2011
Journal Name
Journal Of Liquid Chromatography &amp; Related Technologies
RAPID DETERMINATION OF SPHINGANINE AND SPHINGOSINE IN URINE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY USING MONOLITHIC COLUMN
...Show More Authors

A rapid high performance liquid chromatography method for the determination of sphinganine (Sa) and sphingosine (So) in urine samples by employing a silica-based monolithic column is described. The samples were first extracted using ethyl acetate and derivatized using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol. C20 sphinganine was used as internal standard. Under the optimized conditions, separation was achieved using a mixture of methanol:water (93:7, v/v), column temperature at 30°C, flow rate of 1 mL min−1, and an injection volume of 10 μL. Good linearity was obtained for Sa and So over the concentration range 20–500 ng mL−1(correlation coefficients ≥0.9978). The detection limits were 0.45 ng mL−1 for Sa and

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Aip Conference Proceedings
Determination of paracetemol in pharmaceutical preparations samples by spectrophotometer using meta phenylenediamine as a chromogenic agent
...Show More Authors

View Publication
Crossref (1)
Scopus Crossref