Preferred Language
Articles
/
lOaZLZ4BmraWrQ4dgl_4
Nonlinear Buckling Analysis of Steel Cylindrical Shell with Elliptical Cut-out Subjected to Longitudinal Compressive Load
...Show More Authors

The current paper investigates the effect of cut-out design parameters on load-bearing capacity and buckling behaviour of steel cylindrical shell using a nonlinear finite element analysis in modelling cylinder buckling under longitudinal compressive load. The effect of four geometry design parameters: shell diameter to thickness ratio, cut-out location, orientation, and size were investigated in this study. To enhance the prediction of buckling behaviour, both geometrical and material nonlinearities were considered. An ANSYS APDL code was written and tested by verifying its validity through comparison with former buckling study. The results showed that changing the cut-out location from mid-height of the cylindrical shell towards a fixed edge caused an increase in the buckling load value. Moreover, the study showed that increasing parameters such as shell thickness and cut-out orientation have a positive influence in which the buckling load value increased too. For fast design purposes, an empirical numerical based regression formula was presented for the calculation of the critical buckling load of a cylindrical shell having an elliptical cut-out.

Scopus Crossref
View Publication
Publication Date
Sat Aug 01 2026
Journal Name
The American Journal Of Cardiology
Lipoprotein(a) Distribution Across Race/Ethnicity and Association With Mortality Outcomes in NHANES III (1988 to 1994) With Follow‑Up to 2019
...Show More Authors

View Publication
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Experimental and numerical investigation on the behavior of reinforced reactive powder concrete two-way slabs under static load
...Show More Authors

This paper studied the behaviour of reinforced reactive powder concrete (RPC) two-way slabs under static load. The experimental program included testing three simply supported slabs of 1000 mm length, 1000 mm width, and 70 mm thickness. Tested specimens were of identical properties except their steel fibers volume ratio (0.5 %, 1 %, and 1.5 %). Static test results revealed that, increasing steel fibers volume ratio from 0.5% to 1% and from 1% to 1.5%, led to an increase in: first crack load by (32.2 % and 52.3 %), ultimate load by (36.1 % and 17.0 %), ultimate deflection by (33.6 % and 3.4 %), absorbed energy by (128 % and 20.2 %), and the ultimate strain by (1.1 % and 6.73 %). The stiffness and ductility of the specimens also increased. A

... Show More
View Publication
Publication Date
Wed Jul 01 2020
Journal Name
Journal Of Engineering
Utilizing Load and Loss Factors in Determination of the Technical Power Losses in Distribution System’s Feeders: Case Study
...Show More Authors

This study uses load factor and loss factor to determine the power losses of the electrical feeders. An approach is presented to calculate the power losses in the distribution system. The feeder’s technical data and daily operation recorded data are used to calculate and analyze power losses.

This paper presents more realistic method for calculating the power losses based on load and loss factors instead of the traditional methods of calculating the power losses that uses the RMS value of the load current which not consider the load varying with respect to the time. Eight 11kV feeders are taken as a case study for our work to calculate load factor, loss factor and power losses. Four of them (F40, F42, F43 and F

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Oct 02 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Histological and histomorphometric analysis of strontium chloride coated commercially pure titanium implant compared with hydroxyapatite coating
...Show More Authors

Background: In recent years, the immediate loading of dental implants has become more accepted as a standard protocol for the treatment of the edentulous area. Success in implant dentistry depends on several parameters that may improve phenomenon of osseointegration and new bone formation in close contact with the implant. The aim of study was to evaluate the effect of strontium chloride coating of screw shape commercially pure titanium dental implant osseointegration at bone - implant interface by histomorphometric analysis and compare with hydroxyapatite coating at 2 time periods (2 weeks and 6 weeks). Materials and methods: Electrophoretic Deposition Technique (EPD) was used to obtain a uniform coating layer on commercially pure titanium

... Show More
View Publication Preview PDF
Publication Date
Fri Oct 02 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Histomorphometric analysis of bone deposition at Ti implant surface dip-coated with hydroxyapatite (In vivo study)
...Show More Authors

Background: Synthetic hydroxyapatite,(Ca10(PO4)6(OH2) can directly bond to bones without infection and fibrous encapsulation, thus is regarded as bioactive and biocompatible. The aim of the study was the estimation of microarchitecture bone parameters include bone mass (gm/cm2) cortical bone width (mm), thread width (mm), marrow space star volume analysis (V*m) and osteoblast, osteocyte cell number. Materials and methods: Ninety-six (96) commercially pure titanium CpTi) used in this study, (48) implants were coated with HA by dipping coating and (48) implants were used as control. They were inserted in (32) Newzland white rabbits and followed for 2 & 6 weeks. Mechanical torque removal test and histomorphometric analysis of bone microarchit

... Show More
View Publication Preview PDF
Publication Date
Fri Nov 01 2019
Journal Name
Iop Conference Series: Earth And Environmental Science
Phisco-Chemical analysis and sensory evaluation of Iraqi cake incorporated with grape and date (Zahidi) syrup
...Show More Authors
Abstract<p>In this research, The effect of substituting sucrose with different level of DS and DG (0, 25, 30,50,70 and 100%) on the physiochemical, microbial and sensory properties of cake were studied. Cake models were as well construed for microbial content and organic structure during, before then next 35 days storing at experimental temperature. Results showed no significant variances (p < 0.01) in the chemo physical structure of the date and grape test cake for protein values while there were significant differences for Asch, fiber and fat content values, Sensory assessment results showed high significant variance (p < 0.01) among the cake trials with the exemption of texture (6.04-6.</p> ... Show More
View Publication
Scopus (6)
Crossref (4)
Scopus Crossref
Publication Date
Sat Jun 01 2024
Journal Name
Results In Engineering
Stability analysis for the phytoplankton-zooplankton model with depletion of dissolved oxygen and strong Allee effects
...Show More Authors

View Publication Preview PDF
Scopus (28)
Crossref (22)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Aip Conference Proceedings
Analysis of performance measures with single channel fuzzy queues under two class by using ranking method
...Show More Authors

View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Sat Jun 01 2024
Journal Name
Applied Thermal Engineering
Design and optimization of a household photovoltaic/thermal collector with serpentine tube: Energy and exergy analysis
...Show More Authors

View Publication
Scopus (35)
Crossref (36)
Scopus Crossref
Publication Date
Sat Aug 01 2015
Journal Name
Journal Of Bridge Engineering
Torsional Analysis of Multicell Concrete Box Girders Strengthened with CFRP Using a Modified Softened Truss Model
...Show More Authors

Scopus (39)
Crossref (31)
Scopus Clarivate Crossref