Arterial aneurism and stenosis are disorders that lead to circulation malfunction. Stenosis often leads to hypoxia of the organ depending on the affected artery, whilst aneurism can lead to dissection with known lethal consequences. On both cases, the pulse wave produced by the contracting heart is reflected at these discontinuities, and estimating the size of these reflected waves using wave intensity analysis (WIA) is the main aim of this work. We also aim to measure wave speed, or pulse wave velocity (PWV) as more commonly known within the discontinuities. We manufactured 4 stenosis and 4 aneurism silicon sections, connected one at a time to a mother tube, and tested in vitro. Pressure and flow were measured proximal to the discontinuity and were used to calculate WIA. PWV was calculated using the foot to foot technique and also the classical Moens-Korteweg and Bramwell-Hill equations. Wave speed in an aneurism decreases, whereas it increases in a stenosis, all compared to the values determined in a standard mother tube. Presence of aneurisms resulted in a backward expansion whilst the presence of stenosis resulted in a backward compression wave, which related linearly to the size of the discontinuity. Larger aneurisms and smaller stenosis cause an increase in wave reflection.
The solidification process in a multi-tube latent heat energy system is affected by the natural convection and the arrangement of heat exchanger tubes, which changes the buoyancy effect as well. In the current work, the effect of the arrangement of the tubes in a multi-tube heat exchanger was examined during the solidification process with the focus on the natural convection effects inside the phase change material (PCM). The behavior of the system was numerically analyzed using liquid fraction and energy released, as well as temperature, velocity and streamline profiles for different studied cases. The arrangement of the tubes, considering seven pipes in the symmetrical condition, are assumed at different positions in the system, i
... Show MoreBackground: The fracture of instruments within root canal during endodontic treatment is a common incidence, fracture because of fatigue through flexure occurs due to metal fatigue, this study aimed to assess the effect of curvature angle and rotational speed on the cyclic fatigue of different type of Endodontic NiTi Rotary Instruments and compare among them. Materials and method: Three types of rotary instruments with tip size 0.25: ProTaPer F2 (Densply, Malifier) Revo-S SU( 0.06 taper, MicroMega) and RaCe system (0.06 taper, FKG, Dentaire), Forty file of each instrument were used within two canals with angle of curvature (40 &60 )at two speed (250&400)RPM, twelve group were formed for all instruments(total number=120),ten file fo
... Show MoreThe speed of skills has become linked to modern methods of individual and group play, and each of them has begun to serve the other tactically. Through the follow-up of the researchers, they noticed that there is a significant weakness in the speed of performance and slowness in mental preparation, which plays a major role in understanding mental readiness, which is linked to the speed of making decisions during the game, as well as the weakness of the physical speed of the female players, which in turn has an impact on the skill performance of the players of the Iraqi clubs, which are the main supporter of the national team. The study aimed to identify the effect of interactive speed training on the performance of some skills among
... Show MoreNEACADEMY's JOURNALS
This article presents a new cascaded extended state observer (CESO)-based sliding-mode control (SMC) for an underactuated flexible joint robot (FJR). The control of the FJR has many challenges, including coupling, underactuation, nonlinearity, uncertainties and external disturbances, and the noise amplification especially in the high-order systems. The proposed control integrates the CESO and SMC, in which the CESO estimates the states and disturbances, and the SMC provides the system robustness to the uncertainty and disturbance estimation errors. First, a dynamic model of the FJR is derived and converted from an underactuated form to a canonical form via the Olfati transformation and a flatness approach, which reduces the complexity of th
... Show MoreThe flexible joint robot manipulators provide various benefits, but also present many control challenges such as nonlinearities, strong coupling, vibration, etc. This paper proposes optimal second order integral sliding mode control (OSOISMC) for a single link flexible joint manipulator to achieve robust and smooth performance. Firstly, the integral sliding mode control is designed, which consists of a linear quadratic regulator (LQR) as a nominal control, and switching control. This control guarantees the system robustness for the entire process. Then, a nonsingularterminal sliding surface is added to give a second order integral sliding mode control (SOISMC), which reduces chartering effect and gives the finite time convergence as well. S
... Show MoreBackground: Although various imaging modalities are available for evaluating suspicious breast lesions, ultrasound-based Shear-Wave Elastography (SWE) is an advanced, non-invasive technique complementary to grayscale sonography. This technique evaluates the elasticity of a specific tissue by applying sonic pressure to that tissue.
Objective: The aim is to assess the role of SWE in evaluating solid breast masses in correlation to histopathological study results.
Subjects and Methods: This prospective study was done in a tertiary care teaching hospital from September 2019 to August 2020. A study population of 50 women aged 18 years or above with an
... Show MoreIn this study, the energy charging mechanism is mathematically modeled to determine the impact of design modifications on the thermofluidic behavior of a phase change material (PCM) filled in a triplex tube containment geometry. The surface area of the middle tube, where the PCM is placed, is supported by single or multi-internal frustum tubes in vertical triplex tubes to increase the performance of the heating and cooling of the system. In addition to the ordinary straight triplex tubes, three more scenarios are considered: (1) changing the middle tube to the frustum tube, (2) changing the inner tube to the frustum tube, and (3) changing both the internal and central tubes to the frustum tubes. The impact of adopting the tube desig
... Show MoreThis study presents a transient thermo-mechanical finite element framework for high-speed end milling of AISI 4340 steel. The model couples moving heat sources, rate- and temperature-dependent plasticity, and adaptive mesh refinement (AMR) triggered by temperature gradient, plastic strain rate, and contact pressure. It is integrated with a design of experiments/response surface methodology using cutting speed (VC), feed per tooth (fZ), radial depth of cut/width of cut (ae), axial depth of cut (ap), and coolant mode. Responses include peak interface temperature per tooth (Tpeak), predicted surface residual stress (?_xx^"surf" ), and depth of compressive residual stress layer (dcomp). Experiments provide X-ray diffraction-based surfac
... Show More