Preferred Language
Articles
/
khaV3osBVTCNdQwCv-Kx
The Importance of Using Metaverse Technology in Education from the Point of View of University Teachers
...Show More Authors

The study aims to demonstrate the significance of metaverse technology across various disciplines, academic degrees, scientific fields, and academic titles. It also aims to assess the level of knowledge and understanding of university teachers (research sample) regarding metaverse technology. Hence, the descriptive research methodology was based on the method of statistical survey in the sample. It involved a set of organized scientific steps to deduce data from the reality of the statistical sample and its nature in order to achieve the objectives of the study. In this study, a questionnaire was used as a tool to collect data from a random sample of approximately 121 teachers and instructors from the University of Baghdad. This approach helped the study draw important conclusions and make recommendations. Specifically, the study found the following: there is a need for a clear understanding of the importance of implementing metaverse technology in university education; teachers in scientific colleges are more aware of its importance compared to their counterparts in humanitarian colleges; there is a strong call for all universities, colleges, and academic institutions to prioritize the application of metaverse technology in university education; there should be the availability of all necessary supplies and devices; and there should be the creation of an appropriate environment for teachers to effectively use metaverse technology when teaching students.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jun 11 2021
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of composite bonding spot size and location on the performance of poly-ether-ether-ketone (PEEK) retainer wires
...Show More Authors

Background: Poly-ether-ether-ketone(PEEK) has been introduced to many dental fields. Recently it was tested as a retainer wire‎ following orthodontic treatment. This study aimed to investigate the effect of changing the bonding spot size and location on the performance of PEEK retainer wires. Methods: A biomechanical study involving four three-dimensional finite element models was performed. The basic model was with a 0.8 mm cylindrical cross-section PEEK wire, bonded at the center of the lingual surface of the mandibular incisors with 4 mm in diameter composite spots. Two other models were designed with 3 mm and 5 mm composite sizes. The last model was created with the composite bonding spot of the canine away from the center

... Show More
Scopus (13)
Crossref (9)
Scopus Crossref
Publication Date
Mon Dec 20 2021
Journal Name
Journal Of Craniofacial Surgery
The Effect of Bone Density Measured by Cone Beam Computed Tomography and Implant Dimensions on the Stability of Dental Implants
...Show More Authors

Abstract: The aim of this study was to evaluate the effect of bone density value in Hounsfield unit derived from cone beam computed tomography (CBCT), and implant dimensions in relation to implant stability parameters namely the resonance frequency analysis and the insertion torque (IT) value. It included 24 patients who received 42 dental implants (DI). The bone density of the planned implant site was preoperatively measured using cone beam computed tomography. The implant stability was measured using Osstell implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. The IT value was categorized as 35 N/cm or > 35 N/cm. The mean (standard deviation) primary stability was 79.58 (5.27) ISQ,

... Show More
View Publication
Scopus (13)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Fri Jun 11 2021
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of composite bonding spot size and location on the performance of poly-ether-ether-ketone (PEEK) retainer wires
...Show More Authors

Background: Poly-ether-ether-ketone(PEEK) has been introduced to many dental fields. Recently it was tested as a retainer wire‎ following orthodontic treatment. This study aimed to investigate the effect of changing the bonding spot size and location on the performance of PEEK retainer wires. Methods: A biomechanical study involving four three-dimensional finite element models was performed. The basic model was with a 0.8 mm cylindrical cross-section PEEK wire, bonded at the center of the lingual surface of the mandibular incisors with 4 mm in diameter composite spots. Two other models were designed with 3 mm and 5 mm composite sizes. The last model was created with the composite bonding spot of the canine away from the center of t

... Show More
View Publication Preview PDF
Scopus (13)
Crossref (9)
Scopus Crossref
Publication Date
Fri Nov 27 2020
Journal Name
Journal Of Physics: Conference Series
Investigation of the State Vectors and Prediction of the Orbital Elements for Spot-6 Satellite during 1300 periods with Perturbations
...Show More Authors
Abstract<p>Computer simulations were carried out to investigate the dependence of the main perturbation parameters (Sun and Moon attractions, solar radiation pressure, atmosphere drag, and geopotential of Earth) on the orbital behavior of satellite. In this simulation, the Cowell method for accelerations technique was adopted, the equation of motion with perturbation was solved by 4<sup>th</sup> order Runge-Kutta method with step (1/50000) of period to obtain the state vectors for position and velocity. The results of this simulation have been compared with data that available on TLEs (NORD data in two line elements). The results of state vectors for satellites (Cartosat-2B, Gsat-14 an</p> ... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Sun Dec 01 2013
Journal Name
Bulletin Of The Iraq Natural History Museum (p-issn: 1017-8678 , E-issn: 2311-9799)
NEW RECORD OF NANOSESARMA SARII (NADERLOO AND YURKAY, 2009) (CRUSTACEA: DECAPODA: BRACHYURA: SESARMIDAE) FROM KNOR AL-ZUBAIR, SOUTH OF IRAQ
...Show More Authors

    Specimens of the sesarmid crab Nanonsesarma sarii  (Naderloo and Türkay 2009) were    collected from the intertidal zone of Khor Al-Zubair, Basrah, Iraq 2012 far from the Arabian Gulf coasts. Morphological features of this species are highlighted and a figure is provided. 

 

View Publication Preview PDF
Publication Date
Mon Mar 26 2012
Journal Name
Journal Of Kufa For Chemical Sciences
Synthesis and Characterization of some lanthanide Metal ions Complexes of Schiff Bases derived From p-fluoro benzoic acid and thiosemicarbazide
...Show More Authors

Reaction of  p-fluoro benzoic acid with the thiosemicarbazide and salcialdehyde gave the new bidentate ligand .The prepared ligand Identified by FT-I.R and U.V-Visible spectcopic technique .Treatment of the prepared   ligand   with following metal ions  M=Tb(III),Eu(III),Nd(III) and La(III) ,in ethanol with a (1:1) M:L ratio and at pH=7 yielded series of neutral complexes as the general formula  [M LCl (H O ]. The prepared complexes were characterized using (FT-IR, UV-Vis) spectra , melting point, molar conductivity measurements . chloride ion content were also evolution by (mhor method) . The proposed structure of the complexes using program , chem office 3D(2004) .

Publication Date
Sun Jun 30 2019
Journal Name
Journal Of Global Pharma Technology
Synthesis, Spectral and Antibacterial Activity of Mixed Ligand from Lanthanium (III) Complexes of Schiff Base Ligand with Some Amino Acids
...Show More Authors

In this work, lanthanium (III) complexes were synthesized using by Schiff base ligand (L) derived from benzaldehyde and o-aminoaniline with five amino acids (AA) from glycine (Gly), L-alanine (Ala), L-valine (Val), L-asparagine (Asp) and DL- phenylalanine (Phe). The Schiff base ligand has been characterized by elemental analysis, (MASS, FTIR, 1HNMR, 13CNMR, UV-VIS) electronic spectra. The structures of the new complexes have been described of analysis of elements, molar conductivity, (UV-Vis electronic, FTIR, mass) spectra also magnetic moment. The molar conductivity values of the complexes indicat this every of complexes are electrolytes and other analytical studies reveal octahedral geometry for La (III) ion. The Schiff base ligand, five

... Show More
View Publication
Publication Date
Thu Jul 01 2010
Journal Name
Bulletin Of The Iraq Natural History Museum (p-issn: 1017-8678 , E-issn: 2311-9799)
NEW SUB-SPECIES OF CHUKAR PARTRIDGE ALECTORIS CHUKAR (GRAY 1830) (PHASIANIDAE, GALLIFORMES) FROM NORTH EAST OF IRAQ WITH BIOLOGICAL OBSERVATIONS
...Show More Authors

Chukar partridge Alectoris chukar (Gray, 1830) is the only species of the 46 species of the genus Alectoris to be found in Iraq. At least there are fourteen subspecies of chukar were described from east Europe, the Middle East and west Asia, two of them were known to be found in Iraq, A.c. Kurdestanica (Meinertzhagen, 1923) from Alpine bio-geographical zone of altitude more than 2000m high, and A.c. werae Zarundny and Loudon, 1904, from the foothills of altitude not more than 400m. In between these two regions, there is another bio-geographical region known as the Irano-toranian zone 400-2000m high. Using morphological, ecological, behavioural, reproduction and hybridization criteria this study discove

... Show More
View Publication Preview PDF
Publication Date
Tue Apr 01 2025
Journal Name
Natural And Engineering Sciences
Comparison of Some Soil Mineral’s Ability to Adsorb and Release Lead and Rates of its Removal From its Aqueous Solutions
...Show More Authors

To study the comparative use of some soil minerals (zeolite, bentonite, phosphate rock, and limestone) in the adsorption and release of lead and its removal rates from its aqueous solutions using adsorption equations. Two laboratory experiments were carried out for the adsorption and release of lead. The adsorption experiment took 0.5 g of some of the above soil minerals. Lead was added as Pb (NO3)2 at levels of 3.0, 2.0, 1.5, 1.0, 0.5, and 0.0 mmol L-1 containing a concentration of 0.01M of calcium chloride. The experimental unit’s number was 72, the concentration of dissolved lead in the equilibrium solution was estimated and the amount of lead adsorbed was calculated. As for the lead release experiment, samples fo

... Show More
View Publication
Scopus Crossref
Publication Date
Sat May 31 2025
Journal Name
Iraqi Journal For Computers And Informatics
Discussion on techniques of data cleaning, user identification, and session identification phases of web usage mining from 2000 to 2022
...Show More Authors

The data preprocessing step is an important step in web usage mining because of the nature of log data, which are heterogeneous, unstructured, and noisy. Given the scalability and efficiency of algorithms in pattern discovery, a preprocessing step must be applied. In this study, the sequential methodologies utilized in the preprocessing of data from web server logs, with an emphasis on sub-phases, such as session identification, user identification, and data cleansing, are comprehensively evaluated and meticulously examined.

View Publication Preview PDF
Crossref