Preferred Language
Articles
/
k4bMgYYBIXToZYALaow8
DETERMINATION OF THE GEOID HEIGHT (GEOID UNDULATION) BY USING MODERN SURVEYING TECHNOLOGIES
...Show More Authors

In this work, a large part of Baghdad University campus has been selected. The determination of Geoidal height for the local area requires Ground Control Points which both Ellipsoidal and Orthometric heights are known to compute the difference between them. The first step of the leveling process began by selected the Ground Control Points (GCPs) around the area of the work, and then divided them into two groups of the network traverse stations. They were leveled and adjusted depend on the number of the Bench Marks (B.M.s). Total Station TS (Nikon Nivo 5C) and Global Positioning System (GPS-Garmin 78 map) are used to do this application. The aim of the proposed work was to determine the height of the Geoid surface in the study area. The Geoidal height is calculated from the difference between the two different heights (Orthometric and Ellipsoidal) for the same point and using Geoid Model (EGM) method, then to compare between them. Maximum and the minimum values for the Geoid Undulation are (1.6261 m), and (1.5964 m) respectively with average (1.61 meter) by using (EGM 2008). When it is used the difference method (h-H), maximum and the minimum values for the Geoid Undulation are (5 m), and (2 m) respectively. Finally, the model EGM-2008 represents the best method to determine the Geoid Undulation. dN value between the two different methods is a maximum (3.40) m, a minimum (0.40 m), the average value (1.5 m), and a standard deviation (SD)= ±0.030. At last, image map was produced using Arc GIS 10.1.

Publication Date
Fri Mar 15 2019
Journal Name
Journal Of The College Of Education For Women
Assessing the Brief Book of the Modern and Contemporary History of Asia from the Perspective of the Students in the Department of History - University of Baghdad
...Show More Authors

The current research aims to assess the Brief Book of the Modern and Contemporary History of Asia from the perspective of the students in the Department of History, University of Baghdad. The study is carried out in Iraq and the research group has included students of the Department of History in the College of Education--Ibn Rushd and the College of Education for Women- University of Baghdad. The chosen sample of the assigned research consisted of (72) students from third stage in the Department of History, which equals (0.38%) of the total group members amounted (188) female and male students representing (40) students from the College of Education--Ibn Rushd, and 32 students from

... Show More
View Publication Preview PDF
Publication Date
Fri Apr 30 2021
Journal Name
Egyptian Journal Of Chemistry
Indirect Spectrophotometric Determination of Mebendazole Using NBromosuccinimide as An Oxidant and Tartarazine Dye as Analytical Reagent
...Show More Authors

A simple indirect spectrophotometric method for determination of mebendazol in pure and pharmaceutical formulation was presented in this study. UV-Visible spectrophotometry using the optimal conditions was developed for determination of mebendazole in pure drug and different preparation samples. The method is based on the oxidation of drug by nbromosuccinimide with hydrochloric acid and the left amount of oxidizing agent was determined by the reaction with tartarazine and the absorbance was measured at 428 nm. Calibration curves were linear in the range of 5 to 30 µg.mL-1 with molar absorptivity 8437.2 L.mol-1 .cm-1 . The limits of detection and quantification were determined and found to be 0.7770 µg.mL-1 and 2.3400 µg.mL-1 respec

... Show More
Publication Date
Tue Jan 01 2019
Journal Name
Indian Journal Of Public Health Research & Development
Spectrophotometric Determination of Nifedipine in Pharmaceutical Tablets Using Batch and Flow Injection Method Via Diazotization Coupling Reaction
...Show More Authors

View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Sun Apr 25 2021
Journal Name
Egyptian Journal Of Chemistry
Indirect spectrophotometric determination of Mebendazole using n-bromosuccinimide as an oxidant and tartarazine dye as analytical reagent
...Show More Authors

View Publication Preview PDF
Scopus (12)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Jul 01 2019
Journal Name
Biocatalysis And Agricultural Biotechnology
Determination of Diazinon in fruit samples using electrochemical sensor based on carbon nanotubes modified carbon paste electrode
...Show More Authors

View Publication
Crossref (44)
Crossref
Publication Date
Thu Dec 22 2022
Journal Name
Chemistry & Chemical Technology
Turbidimetric Determination of Mebeverine Hydrochloride in Pharmaceutical Formulations Using Two Consecutive Detection Zones under Continuous Flow Conditions
...Show More Authors

A simple, low cost and rapid flow injection turbidimetric method was developed and validated for mebeverine hydrochloride (MBH) determination in pharmaceutical preparations. The developed method is based on forming of a white, turbid ion-pair product as a result of a reaction between the MBH and sodium persulfate in a closed flow injection system where the sodium persulfate is used as precipitation reagent. The turbidity of the formed complex was measured at the detection angle of 180° (attenuated detection) using NAG dual&Solo (0-180°) detector which contained dual detections zones (i.e., measuring cells 1 & 2). The increase in the turbidity of the complex was directly proportional to the increase of the MBH concentration

... Show More
View Publication
Scopus (10)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Wed Mar 18 2020
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Copper(II) using 2,2[O-Tolidine-4,4-bis azo]bis[4,5-diphenyl imidazole](MBBAI)
...Show More Authors

            Spectrophotometric method was developed for the determination of copper(II) ion. Synthesized (2,2[O-Tolidine-4,4-bis azo]bis[4,5-diphenyl imidazole]) (MBBAI) was used as chromogenic reagent at pH=5. Various factors affecting complex formation, such as, pH effect, reagent concentration, time effect and temperature effect, have been considered and studied. Under optimum conditions concentration ranged from (5.00-80.00) µg/mL of copper(II) obeyed Beer`s Low. Maximum absorption of the complex was 409nm with molar absorpitivity 0.127x104 L mol-1 cm-1. Limit of detection(LOD) and Limit of quantification were 1.924 and 6.42 μg/mL, respectively.

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Jul 01 2012
Journal Name
Food Chemistry
High performance liquid chromatographic determination of aflatoxins in chilli, peanut and rice using silica based monolithic column
...Show More Authors

A simple and rapid high performance liquid chromatographic with fluorescence detection method for the determination of the aflatoxin B1, B2, G1 and G2 in peanuts, rice and chilli was developed. The sample was extracted using acetonitrile:water (90:10, v/v%) and then purified by using ISOLUTE multimode solid phase extraction. After the pre-column derivatisation, the analytes were separated within 3.7 min using Chromolith performance RP-18e (100–4.6 mm) monolithic column. To assess the possible effects of endogenous components in the food items, matrix-matched calibration was used for the quantification and validation. The recoveries of aflatoxins that were spiked into food samples were 86.38–104.5% and RSDs were <4.4%. The method was

... Show More
View Publication
Scopus (85)
Crossref (77)
Scopus Clarivate Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Baghdad Science Journal
Simultaneous Determination of Piroxicam and Codeine Phosphate Hemihydrate in a Pharmaceutical Dosage Form Using Validated HPLC Method
...Show More Authors

An easy, eclectic, precise high-Performance Liquid Chromatographic (HPLC) procedure was evolved and validated to estimate of Piroxicam and Codeine phosphate. Chromatographic demarcation was accomplished on a C18 column [Use BDS Hypersil C18, 5μ, 150 x 4.6 mm] using a mobile phase of methanol: phosphate buffer (60:40, v/v, pH=2.3), the flow rate was 1.1 mL/min, UV detection was at 214 nm. System Suitability tests (SSTs) are typically performed to assess the suitability and effectiveness of the entire chromatography system. The retention time for Piroxicam was found to be 3.95 minutes and 1.46 minutes for Codeine phosphate. The evolved method has been validated through precision, limit of quantitation, specificity,

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Fri May 01 2020
Journal Name
Iraqi Geological Journal
DETERMINATION OF PORE TYPES AND POROSITY TRENDS USING OF VELOCITY-DEVIATION LOG FOR THE CARBONATE MISHRIF RESERVOIR IN HALFAYA OIL FIELD, SOUTHEAST IRAQ
...Show More Authors

View Publication
Scopus (16)
Crossref (2)
Scopus Crossref