Researching performance audits according to the dimensions of financial sustainability in light of the scarcity of resources and economic and social transformations in the business environment is of utmost importance in the non-profit non-governmental organizations in achieving the goals and correct the path and address deviations, and help them in improving the outputs of processes and associated procedures and capacity The research was based on the hypothesis that the existence of a performance audit program in accordance with the dimensions of financial sustainability leads to the measurement of the commitment of the Olympic Committee. National Iraqi indicators of financial sustainability of the dimension of revenue in order to improve performance and achieve financial sustainability. The researchers sought to employ the indicators of financial sustainability in the preparation of a proposed performance audit program for the Iraqi National Olympic Committee. The researchers reached a number of conclusions, the most important of which is that the study of financial sustainability and its indicators and the integration of these indicators with the performance audit indicators according to the dimensions of financial sustainability will improve performance and ensure financial sustainability in (non-profit) non-governmental organizations. The existence of a program and indicators of performance auditing in accordance with the dimensions of financial sustainability for non-governmental organizations and the Iraqi National Olympic Committee accredited by the Federal Audit Bureau in Iraq.
In this paper, a miniaturized 2 × 2 electro-optic plasmonic Mach– Zehnder switch (MZS) based on metal–polymer–silicon hybrid waveguide is presented. Adiabatic tapers are designed to couple the light between the plasmonic phase shifter, implemented in each of the MZS arms, and the 3-dB input/output directional couplers. For 6 µm-long hybrid plasmonic waveguide supported by JRD1 polymer (r33= 390 pm/V), a π-phase shift voltage of 2 V is obtained. The switch is designed for 1550 nm operation wavelength using COMSOL software and characterizes by 2.3 dB insertion loss, 9.9 fJ/bit power consumption, and 640 GHz operation bandwidth
The paper present design of a control structure that enables integration of a Kinematic neural controller for trajectory tracking of a nonholonomic differential two wheeled mobile robot, then proposes a Kinematic neural controller to direct a National Instrument mobile robot (NI Mobile Robot). The controller is to make the actual velocity of the wheeled mobile robot close the required velocity by guarantees that the trajectory tracking mean squire error converges at minimum tracking error. The proposed tracking control system consists of two layers; The first layer is a multi-layer perceptron neural network system that controls the mobile robot to track the required path , The second layer is an optimization layer ,which is impleme
... Show MoreThis study aimed at evaluating the torsional capacity of reinforced concrete (RC) beams externally wrapped with fiber reinforced polymer (FRP) materials. An analytical model was described and used as a new computational procedure based on the softened truss model (STM) to predict the torsional behavior of RC beams strengthened with FRP. The proposed analytical model was validated with the existing experimental data for rectangular sections strengthened with FRP materials and considering torque-twist relationship and crack pattern at failure. The confined concrete behavior, in the case of FRP wrapping, was considered in the constitutive laws of concrete in the model. Then, an efficient algorithm was developed in MATLAB environment t
... Show MoreThis study offers numerical simulation results using the ABAQUS/CAE version 2019 finite element computer application to examine the performance, and residual strength of eight recycle aggregate RC one-way slabs. Six strengthened by NSM CFRP plates were presented to study the impact of several parameters on their structural behavior. The experimental results of four selected slabs under monotonic load, plus one slab under repeated load, were validated numerically. Then the numerical analysis was extended to different parameters investigation, such as the impact of added CFRP length on ultimate load capacity and load-deflection response and the impact of concrete compressive strength value on the structural performance of
... Show More