The historical center cities were exposed to change, which included its social and economical structures, Which led to sweeping changes in land use, causing a change in the result, in urban fabric and the physical structure and therefore to see visual. We have attracted these centers as a result of pressure from urban development and contemporary reflection of the agents of change which have been hit during the late period a development residential newly not sympathize mostly with the content of the historical and at the expense of removing large parts of the urban fabric and replace it with patterns of structural and styles of architecture has not been connected with reality. Which led to the loss of some historical and architectural features that have characterized these centers. Thus, the associated problem of search by selecting the "ground that led to changes in those centers, which came to meet the requirements of present and future have changed land-use and affect in determining the configurations of urban multiple centers ". The research aims to "statement of the potential of the configuration of urban historic centers of cities and to identify the factors that led to change the architectural character and historical identity and signaling transformation and change, which gets started in the traditional core functions and uses of the land and diagnosis resulting from the change of the composition of visual effects hit and installation of urban. " The research approach adopted was associated with levels of finds, including a link development in city centers to take practical steps were the possibility of re-lines and spaces of the traditional city center with the positioning of the economic attractions
the behavior of the first-order black and gray solitons propagtedin optical fiber in the presence of frequency chirp is studied analytically and numerically results show that phase profile of black solitons changes abruptly
This research came with the aim of showing the impact of governance mechanisms on tax avoidance practices, and in light of this, the financial data of the joint stock companies (industrial, service, agricultural, and hotels) listed in the Iraq Stock Exchange amounting to (35) companies were collected during the period (2009-2020). Through the financial reports published on the market website, multiple linear regression analysis was used as a tool to study the relationship between variables, and (Eviews 12) program was used for analysis and hypothesis testing. To achieve the objectives of the research,(administrative ownership, board size, board independence, women's membership) was adopted as an indicator of the dimensions of governance, an
... Show MoreIn this paper, the method of estimating the variation of Zenith Path Delay (ZPD) estimation method will be illustrate and evaluate using Real Time Kinematic Differential Global Positioning System (RTK-DGPS). The GPS provides a relative method to remotely sense atmospheric water vapor in any weather condition. The GPS signal delay in the atmosphere can be expressed as ZPD. In order to evaluate the results, four points had been chosen in the university of Baghdad campus to be rover ones, with a fixed Base point. For each rover position a 155 day of coordinates measurements was collected to overcome the results. Many models and mathematic calculations were used to extract the ZPD using the Matlab environment. The result shows that the ZPD valu
... Show MoreThe adsorption isotherms and kinetic uptakes of CO2 were measured. Adsorption isotherms were measured at two temperatures 309 K and 333 K and over a pressure range of 1 to 7 bar. Experimental data of CO2 adsorption isotherms were modeled using Langmuir, Freundlich and Temkin. Based on coefficient of correlation it was found that Langmuir isotherm model was well suited with the experimental data of CO2 adsorption isotherms. In addition, Adsorption kinetic of CO2 mixture with N2 containing 10 % by volume CO2 and 90 % by volume N2 were determined in a temperature 36 °C and under the atmospheric pressure .When the flow rate was increased from
... Show Morehe assignment model represents a mathematical model that aims at expressing an important problem facing enterprises and companies in the public and private sectors, which are characterized by ensuring their activities, in order to take the appropriate decision to get the best allocation of tasks for machines or jobs or workers on the machines that he owns in order to increase profits or reduce costs and time As this model is called multi-objective assignment because it takes into account the factors of time and cost together and hence we have two goals for the assignment problem, so it is not possible to solve by the usual methods and has been resorted to the use of multiple programming The objectives were to solve the problem of
... Show MoreThe present article delves into the examination of groundwater quality, based on WQI, for drinking purposes in Baghdad City. Further, for carrying out the investigation, the data was collected from the Ministry of Water Resources of Baghdad, which represents water samples drawn from 114 wells in Al-Karkh and Al-Rusafa sides of Baghdad city. With the aim of further determining WQI, four water parameters such as (i) pH, (ii) Chloride (Cl), (iii) Sulfate (SO4), and (iv) Total dissolved solids (TDS), were taken into consideration. According to the computed WQI, the distribution of the groundwater samples, with respect to their quality classes such as excellent, good, poor, very poor and unfit for human drinking purpose, was found to be
... Show MoreAn experiment was carried out evaluate the performance of RAU combined equipment under three levels of practical speed, (V1) 4.06 km. h-1, (V2) 4.43 km. hr-1 and (V3) 5.76 km. hr-1, and three levels of depth with 10,20and 30 cm. It is denoted by D1, D2, D3 respectively. A split plot design was used within the RCBD design with three replications. The experiment results showed that the first practical speed 4.06 km.hr-1 achieved the lowest slippage percentage from 9.61%, lowest traction power 14.65hp, lowest soil penetration resistance to1.34 kg.cm-2, and the highest total operating