Preferred Language
Articles
/
joe-982
Study Impact of Unified Power Flow Controller (UPFC) on a Transmission Line Performance under Different Loading Conditions
...Show More Authors

Now-a-days the Flexible AC Transmission Systems (FACTS) technology is very effective in improving the power flow along the transmission lines and makes the power system more flexible and controllable. This paper deals with the most robust type of FACTS devices; it’s a Unified Power Flow Controller (UPFC). Many cases have been taken to study how the system behaves in the presence and absence of the UPFC under normal and contingency conditions. The UPFC is a device that can be used to improve the bus voltage, increasing the loadability of the line and reduce the active and reactive power losses in the transmission lines, through controlling the flow of real and reactive power. Both the magnitude and the phase angle of the voltage can be varied independently. The steady state model of UPFC has been adopted on IEEE-30 bus test system and simulated using MATLAB programming language. Newton Raphson (NR) numerical analysis method has been used for solving the load flow of the system. The practical part has been solved through Power System Simulation for Engineers (PSS\E) software Version 32.0. The Comparative results between the experimental and practical parts obtained from adopting the UPFC where too close and almost the same under different loading conditions, which are (5%, 10%, 15% and 20%) of the total load.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jan 28 2019
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The Role of The Knowledge Management Processes in Insurance Service Performance: An Applied Research at The National Insurance Company
...Show More Authors

The research aims to measure the relationship and the impact of knowledge management processes to achieve the performance of insurance service, as well as analysis of the reality of the National Insurance Company to identify the level of overall performance, and to achieve this goal, it has been the selection of knowledge management processes according to the survey prepared a supplement to the study (Qubaisi, 2002), and of the four operations (knowledge generation, and storage of knowledge, and the distribution of knowledge, and application of knowledge), which represented the independent variable, and the performance has been the use of quantitative and qualitative measures, (sales growth, customer satisfaction), which represented the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
In vitro Performance of Polymethyl–methacrylate with Ultra High Density Poly Ethylene Fiber and Nano Zirconium Oxide Particles Composite
...Show More Authors

Background: Poly (methyl methacrylate) has been widely utilized for fabrication of dentures for many years as it has good advantages but not achieved all demands of the mechanical properties such as low transverse strength, low impact strength, low surface hardness, high water solubility and high water sorption. Material and method: To provide bonding between ZrO2 nanoparticles and PMMA matrix, the ZrO2 Nano-fillers were surface-treated with a saline coupling agent. Plasma surface treatment of polyethylene (PE) fiber was done to change surface fiber by using DC- glow discharge system. For characterization of interring any functional groups, the (FTIR) spectrum were done .then the mechanical properties studied to choose the appropriate perc

... Show More
View Publication
Crossref
Publication Date
Fri May 16 2025
Journal Name
Asian Journal Of Advanced Research And Reports
Conversion of Vegetable Oils into Glycidyl Ethers: The Key Process Moving Towards Sustainability and Improved Performance in Epoxy Resins
...Show More Authors

It is through a review of conversion of vegetable oils into glycidyl ethers focusing on their roles in achieving sustainability and improved epoxy resin performance. It involves functionalization of triglycerides in the form of epoxidation followed by glycidylation and yields bio-based monomers having improved mechanical as well as thermal properties. The review covers the underlying chemistry, production drivers, industrial applications, and future issues, supported by quantitative data and comparative studies. In addition, it integrates recent data on catalyst choice, feedstock flexibility, and environmental performance factors of bio-based resins, indicating their suitability for replacing traditional petroleum-based components.<

... Show More
View Publication
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Ieee Access
Sensing Performance of Modified Single Mode Optical Fiber Coated With Nanomaterials-Based Ammonia Sensors Operated in the C-Band
...Show More Authors

View Publication
Scopus (16)
Crossref (20)
Scopus Clarivate Crossref
Publication Date
Sat Apr 30 2022
Journal Name
Revue D'intelligence Artificielle
Performance Evaluation of SDN DDoS Attack Detection and Mitigation Based Random Forest and K-Nearest Neighbors Machine Learning Algorithms
...Show More Authors

Software-defined networks (SDN) have a centralized control architecture that makes them a tempting target for cyber attackers. One of the major threats is distributed denial of service (DDoS) attacks. It aims to exhaust network resources to make its services unavailable to legitimate users. DDoS attack detection based on machine learning algorithms is considered one of the most used techniques in SDN security. In this paper, four machine learning techniques (Random Forest, K-nearest neighbors, Naive Bayes, and Logistic Regression) have been tested to detect DDoS attacks. Also, a mitigation technique has been used to eliminate the attack effect on SDN. RF and KNN were selected because of their high accuracy results. Three types of ne

... Show More
View Publication
Scopus (19)
Crossref (11)
Scopus Crossref
Publication Date
Sun May 23 2010
Journal Name
Ibn Al- Haitham J. Fo R Pure & Appl. Sc I
Synthesis, Spectroscopic and Dyeing Performance Studies of Some New Heterocyclic Azo Dyes and Their Complexes with Selected Metal Ions
...Show More Authors

Coupling reaction of m-and p- amino acetop henone and p-amino benzoic acid with (LHistidine) gave the new bidentate azo ligands (L1, L2 and L3). The prepared ligands were identified by FT-IR, UV-Vis, 1HNMR and GC- mass sp ectroscopic technique. Treatment of the prepared ligands with the following metal ions (CoII, NiII, CuII, ZnII, CdII and HgII) in aqueous ethanol with a 1:2 M:L ratio and at optimum pH, yielded a series of neutral complexes of the general formula [M (L)2 Cl2]. The prepared complexes were characterized by using flame atomic absorption, FT-IR, UV-Vis and 1HNMR spectroscopic methods as well as magnetic susceptibility and conductivity measurements. Chloride ion content was also evaluated by (Mohr method). The nature of the com

... Show More
Publication Date
Mon Jan 01 2018
Journal Name
2018 Detroit, Michigan July 29 - August 1, 2018
Design and validation of an electronic data logging systems (CAN Bus) for monitoring machinery performance and management- Planting application
...Show More Authors

View Publication
Scopus (7)
Scopus Crossref
Publication Date
Tue Aug 17 2021
Journal Name
مجلة علوم التربية الرياضية
Skill performance in terms of the most important anthropometric variables and motor abilities among junior football players in Iraq
...Show More Authors

Football tennis is a team game derived from the integration of football skills, tennis and some of the laws of volleyball. This game originated in 1920, but it was officially approved in 2010 and an international federation was formed for it. Football tennis, like other sports, has its own basic laws and rules, but it is characterized by physical requirements, the way of playing and how to perform skills. Determining these abilities and working to improve and develop them is important and a scientific step to reach the best results, as the special abilities of the game contribute to mastering technical performance of skills and play without errors and thus competition in an ideal technical and legal situation. The research aims to:

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 12 2018
Journal Name
Iop Conference Series: Materials Science And Engineering
The performance of MnO<sub>2</sub>/graphite electrode for TOC removal from wastewater by indirect electrochemical oxidation process
...Show More Authors

Electrochemical oxidation in the presence of sodium chloride used for removal of phenol and any other organic by products formed during the electrolysis by using MnO2/graphite electrode. The performance of the electrode was evaluated in terms fraction of phenol and the formed organic by products removed during the electrolysis process. The results showed that the electrochemical oxidation process was very effective in the removal of phenol and the other organics, where the removal percentage of phenol was 97.33%, and the final value of TOC was 6.985 ppm after 4 hours and by using a speed of rotation of the MnO2 electrode equal to 200 rpm.

View Publication Preview PDF
Scopus (6)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Determination of Water-Soluble Vitamins in Iraqi Honey Bee and Compare with Others Types by High –Performance Liquid Chromatography
...Show More Authors

High-performance liquid chromatographic methods are used for the determination of water-soluble vitamins with UV-Vis. Detector. A reversed-phase high-performance liquid chromatographic has been developed for determination of water-soluble vitamins. Identification of compounds was achieved by comparing their retention times and UV spectra with those of standards solution. Separation was performed on a C18 column, using an isocratic 30% (v/v) acetonitril in dionozed water as mobile phase at pH 3.5 and flow rate 1.0m/min. The method provides low detection and quantification limits, good linearity in a large concentration interval and good precision. The detection limits ranged from 0.01 to 0.025µg/ml. The accuracy of the method was

... Show More
View Publication Preview PDF
Crossref (4)
Crossref