Preferred Language
Articles
/
joe-979
Corrosion Rate Optimization of Mild-Steel under Different Cooling Tower Working Parameters Using Taguchi Design
...Show More Authors

This study investigates the implementation of Taguchi design in the estimation of minimum corrosion rate of mild-steel in cooling tower that uses saline solution of different concentration. The experiments were set on the basis of Taguchi’s L16 orthogonal array. The runs were carried out under different condition such as inlet concentration of saline solution, temperature, and flowrate. The Signal-to- Noise ratio and ANOVA analysis were used to define the impact of cooling tower working conditions on the corrosion rate. A regression had been modelled and optimized to identify the optimum level for the working parameters that had been founded to be 13%NaCl, 35ᴼC, and 1 l/min. Also a confirmation run to establish the precision of the Taguchi design for optimization the corrosion rate in cooling tower with high reliability. The contour plot had been applied to understand how it can be in finding the relation between the corrosion rate and the working parameters of the cooling tower.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Mar 12 2019
Journal Name
Al-khwarizmi Engineering Journal
Optimization of Diffusion Bonding of Pure Copper (OFHC) with Stainless Steel 304L: .
...Show More Authors

This work deals with determination of optimum conditions of direct diffusion bonding welding of austenitic stainlesssteel type AISI 304L with Oxygen Free High Conductivity (OFHC) pure copper grade (C10200) in vacuum atmosphere of (1.5 *10-5 mbr.). Mini tab (response surface) was applied for optimizing the influence of diffusion bonding parameters (temperature, time and applied load) on the bonding joints characteristics and the empirical relationship was evaluated which represents the effect of each parameter of the process. The yield strength of diffusion bonded joint was equal to 153 MPa and the efficiency of joint was equal to 66.5% as compared with hard drawn copper. The diffusion zone reveals high microhardness than coppe

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Sep 18 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Effects of Thiourea on the Corrosion of Low Carbon Steel in Hydrochloric Acid Solution
...Show More Authors

The c.orrosion rate of  low carbon  steel  in 4M  hydrochlwic acid with and without  presence of thiourea has b.een studied  by gravimetric ahd gasometric methods  over the temperature range 303-333 K.

 

The percentage protection of steel increases  vvith the decrease of thimuea concentrations at  various  temperature range  303-333 K and

approaching highest  protection  (86.82%) at 303K  by using  I X 1 o-4 M

of thiourea. The high concentration .of thiourea  ( lxlo-3 M), enl1ances.

the  corrosion rates and  act  as dcpolariser for  the hydrogen  evolution

reaction,&n

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 23 2020
Journal Name
Baghdad Science Journal
Role of Carbon Dioxide on the Corrosion of Carbon Steel Reinforcing Bar in Simulating Concrete Electrolyte
...Show More Authors

The main factors that make it possible to get the corrosion of reinforcing steel in concrete are chloride ions and the absorption of carbon dioxide from the environment, and each of them works with a mechanism which destroys the stable immunity of rebar in the concrete. In this work the effect of carbon dioxide content in the artificial concrete solution on the corrosion behavior of carbon steel reinforcing bar (CSRB) was studied, potentiostatically using CO2 stream gas at 6 level of concentrations;  0.03 to 2.0  weight percent, and the effect of rising electrolyte temperature was also followed  in the range 20 to 50 C. Tafel plots and cyclic polarization procedures were obeyed to investigate the c

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Sep 01 2010
Journal Name
Al-khwarizmi Engineering Journal
Corrosion Behavior of Ti-6Al-4V Alloy in Different Media
...Show More Authors

     In this work the corrosion behavior of Ti-6Al-4V alloy was studied by using galvanostatic measurements at room temperature in different media which includ sodium chloride (food salt), sodium tartrate (presence in jellies, margarine, and sausage casings,etc.), sodium oxalate (presence in fruits, vegetables,etc.), acetic acid (presence in vinegar), phosphoric acid (presence in drink), sodium carbonate (presence in 7up drink,etc.), and sodium hydroxide in order to compare.

     Corrosion parameters were interpreted in th

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 01 2012
Journal Name
Journal Of Economics And Administrative Sciences
Using Truncated Test for Finding the Parameters of Single Sampling Plan under Distribution of Log-Logistic
...Show More Authors

A group of acceptance sampling to testing the products was designed when the life time of an item follows a log-logistics distribution. The minimum number of groups (k) required for a given group size and acceptance number is determined when various values of Consumer’s Risk and test termination time are specified. All the results about these sampling plan and probability of acceptance were explained with tables.

View Publication Preview PDF
Crossref
Publication Date
Tue Nov 01 2011
Journal Name
International Journal Of Mechanical And Materials Engineering
Simulation and design optimization of magneto rheological control valve
...Show More Authors

Magneto-rheological (MR) Valve is one of the devices generally used to control the speed of Hydraulic actuator using MR fluid. The performance of valve depends on the magnetic circuit design. Present study deals with a new design of MR valve. The finite element analysis is carried out on this valve to optimize its design. The design of the magnetic circuit is accomplished by magnetic finite element software such as Finite Element Method Magnetic (FEMM). The Model dimensions of MR valve, material properties and the circuit properties of valve coil are taken into account. The results of analysis are presented in terms of magnetic strength and magnetic flux density. The valve can be operated with variable flow rate by varying the current. It i

... Show More
View Publication Preview PDF
Scopus (2)
Scopus
Publication Date
Sat Jan 01 2022
Journal Name
Materials Today: Proceedings
Shear strength of steel fibre RC beams under repeated loads
...Show More Authors

Scopus (1)
Scopus Clarivate Crossref
Publication Date
Fri Apr 13 2012
Journal Name
Kut Journal For Economic And Administrative Sciences
Using Different Methods to Estimate the Parameters of Probability Death Density Function with Application
...Show More Authors

In this paper, the maximum likelihood estimates for parameter ( ) of two parameter's Weibull are studied, as well as white estimators and (Bain & Antle) estimators, also Bayes estimator for scale parameter ( ), the simulation procedures are used to find the estimators and comparing between them using MSE. Also the application is done on the data for 20 patients suffering from a headache disease.

Preview PDF
Publication Date
Sat Mar 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Potential and Current Distribution in Flow Through Porous Electrochemical Reactor Working under Limiting Current Conditions
...Show More Authors

View Publication Preview PDF
Publication Date
Sat Dec 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Chromium (VI) Removal from Wastewater by Electrocoagulation Process Using Taguchi Method: Batch Experiments
...Show More Authors

Electrocoagulation is an electrochemical method for treatment of different types of wastewater  whereby sacrificial anodes corrode to release active coagulant (usually aluminium or iron cations) into solution, while simultaneous evolution of hydrogen at the cathode allows for pollutant removal by flotation or settling. The Taguchi method was applied as an experimental design and to determine the best conditions for chromium (VI) removal from wastewater. Various parameters in a batch stirred tank by iron metal electrodes: pH, initial chromium concentration, current density, distance between electrodes and KCl concentration were investigated, and the results have been analyzed using signal-to-noise (S/N) ratio. It was found that the r

... Show More
View Publication Preview PDF