Preferred Language
Articles
/
joe-834
Performance Analyses of 15 kW Grid-Tied Photo Voltaic Solar System Type under Baghdad city climate
...Show More Authors

The performance analyses of 15 kWp (kW peak) Grid -Tied solar PV system (that considered first of its type) implemented at the Training and Energy Research Center Subsidiary of Iraqi Ministry of Electricity in Baghdad city has been achieved. The system consists of 72 modules arranged in 6 strings were each string contains 12 modules connected in series to increase the voltage output while these strings connected in parallel to increase the current output. According to the observed duration, the reference daily yields, array daily yields and final daily yields of this system were (5.9, 4.56, 4.4) kWh/kWp/day respectively. The energy yield was 1585 kWh/kWp/year while the annual total solar irradiation received by solar array system was 1986.4kWh/m2. The average power losses per day of array, system losses and overall losses were (1.38, 0.15, 1.53) kWh/kWp/day respectively. The average capacity factor and performance ratio per year were 18.4% and 75.5% respectively. These results highlighted the performance analyses of this PV solar system located in Baghdad city. The performance can be considered as good and significant comparing with other world PV solar stations.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Oct 01 2019
Journal Name
Journal Of Engineering
Hydraulic Analysis and Performance Evaluation of Combined Trunk Sewers: a Case Study of Baghdad City.
...Show More Authors

Sewer system plays an essential task in urban cities by protecting public health and the environment. The operation, maintenance, and rehabilitation of this network have to be sustainable and scientifically. For this purpose, it is crucial to support operators, decision makers and municipalities with performance evaluation procedure that is based on operational factors. In this paper, serviceability and performance indicator (PI) principles are employed to propose methodology comprising two enhanced PI curves that can be used to evaluate the individual sewers depending on operational factors such as flowing velocity and wastewater level in the sewers. To test this methodology; a case study of al-Rusafa in Baghdad city is

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Feb 28 2019
Journal Name
Journal Of Engineering
Hydraulic Analysis and Performance Evaluation of Combined Trunk Sewers: A Case Study of Baghdad City.
...Show More Authors

Sewer system plays an indispensable task in urban cities by protecting public health and the environment. The operation, maintenance, and rehabilitation of this network have to be in a sustainable and scientific manner. For this purpose, it is important to support operators, decision makers and municipalities with performance evaluation procedure that is based on operational factors. In this paper, serviceability and performance indicator (PI) principles are employed to propose methodology comprising two enhanced PI curves that can be used to evaluate the individual sewers depending on operational factors such as flowing velocity and wastewater level in the sewers. In order to test this methodology; a case study of al-Ru

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
Variation of non-diatomic algae in a martyr monument lake under different climate factors
...Show More Authors
Abstract<p>The current study was conducted in the environment of the Martyr Monument Lake in the city center of Baghdad during 2019 to monitor the impact of climatic conditions such as drought, water shortage, high temperatures in the environment of the city and the lack of water flow during the years 2015 to 2018 and their effects on some of the physical and chemical factors of water and the dynamics of the phytoplankton community in the lake environment. Heterogeneity of some studied environmental factors, including air and water temperature, permeability, water depth, pH, DO, BOD5, nutrients, nitrate, NO3, and phosphates were found. The results showed the effect of climate change and the pres</p> ... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Jul 01 2009
Journal Name
Journal Of The Faculty Of Medicine Baghdad
The Impact of Implementing the Self Finance System on Hospital Utilization Indicators in Baghdad City
...Show More Authors

Background: Ministry of Health, since its establishment, adopted the policy of central financing system and free medical services in all health facilities. The sanction and the decline in per capita spending affect the health financing system, thus in 1997 a new financing policy was adopted as pilot in seven specialized hospital called “self–finance” system in which the cost of care was shifted to the patients, i.e. the funds obtained came from user charges at the health facilities. This system was extended (with some modifications) to all hospitals in 1999 and PHC centers in 2001 and implemented until 2003 when it was discontinued.
Materials and Methods: During the second half of 2004, a review of

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Al-khwarizmi Engineering Journal
Yearly Energy, Exergy, and Environmental (3E) Analyses of A Photovoltaic Thermal Module and Solar Thermal Collector in Series
...Show More Authors

The annual performance of a hybrid system of a flat plate photovoltaic thermal system and a solar thermal collector (PVT/ST) is numerically analyzed from the energy, exergy, and environmental (CO2 reduction) viewpoints. This system can produce electricity and thermal power simultaneously, with higher thermal power and exergy compared to conventional photovoltaic thermal systems. For this purpose, a 3D transient numerical model is developed for investigating the system's performance in four main steps: (1) investigating the effects of the mass flow rate of the working fluid (20 to 50 kg/h) on the temperature behavior and thermodynamic performance of the system, (2) studying the impacts of using glass covers on the different parts of the s

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Mar 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Studying the Performance of Refrigeration Units Powered by Solar Panel
...Show More Authors

An experimental study was conducted to determine the performance of a solar electric refrigeration system. The system contained flat photovoltaic solar panel which absorbs the solar energy and convert it to electrical energy, used to run the refrigeration cycle. Two refrigeration cycles with electrical solar panel were used over a period of 12 months, the first one with classical parts known in refrigeration cycle, while the second one introduced heat exchanger which improves the coefficient of performance by saving the consumed energy. The coefficient of performance of these refrigeration cycles with compressor efficiency 85% are 2.102 and 2.57 respectively. The overall efficiency of the two systems are 18.9% and 23.13%.

View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of Southwest Jiaotong University
Evaluation of Photovoltaic Solar Power of a Dual-Axis Solar Tracking System
...Show More Authors

In this research project, a tip-tilting angle of a photovoltaic solar cell was developed to increase generated electrical power output. An active, accurate, and simple dual-axis tracking system was designed by using an Arduino Uno microprocessor. The system consisted of two sections: software and apparatus (hardware). It was modified by using a group of light-dependent resistor sensors, and two DC servo motors were utilized to rotate the solar panel to a location with maximum sunlight. These components were arranged in a mechanical configuration with the gearbox. The three locations of the solar cell were chosen according to the tilt angle values, at zero angles, which included an optimal 33-degree angle for the Baghdad location and

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Feb 01 2015
Journal Name
Journal Of Economics And Administrative Sciences
Climate change and dust storms in Iraq / 'Baghdad', case study
...Show More Authors

A dust storm in Iraq is a climatic phenomenon common in arid and semi-arid regions . The frequency of the occurrence has increased drastically in the last decade and it is increasing continuously .Baghdad city like the rest of Iraq is suffering from the significant increase in dust storms . In this research , the study of the phenomenon of dust storms for all types (Suspended dust , rising dust , dust storm) , and its relationship with some climate variables (Temperature , rainfall ,wind speed) .The statement of the impact of climate change on this phenomenon to Baghdad station  for the period (1981 – 2012) . Time series has been addressing the phenomenon of storms and cli

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Sep 30 2022
Journal Name
Iraqi Journal Of Science
Utilization of Geographic Information System for hydrological analyses: A case study of Karbala province, Iraq
...Show More Authors

    Analyses are the power point of GIS because GIS can process and analyze different spatial and attribute data, leading to new results for supporting decision makers. The research aims to study advanced hydrologic analyses for the western part of Karbala province, Iraq. The hydrologic analysis is done based on where that DEM creates from the field survey method. This analysis gives digital maps and tables showing the region's main and minor hydrological properties, such as flow direction, flow accumulation, stream order, stream to feature, basin, and watershed maps. Also, it can be calculated as area, perimeter, lengths of streams, and numbers of stream orders for the main watersheds that are effective in the study area. These analy

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jun 30 2019
Journal Name
Journal Of Engineering
Thermal Performance of Plastic Receiver in Solar Collector
...Show More Authors

A plastic tubes used as absorber of active flat plate solar collector (FPSC) for heating water were studied numerically and experimentally. The set-up is located in Babylon (republic of Iraq) 43.80 East longitude and 32.30 North latitude with titled of 450 toward the south direction.  The study involved three dimensions mathematical model for flat coil plastic absorber which solved by FLUENT-ANSYS-R.18 program. Experiments were conducted at outdoor conditions for clear days on January and February 2018 with various water volume flow rates namely (500, 750, 1000, 1250, and 1500 Liter per hour LPH) on each month for Reynolds number range of (1 x 104 to 5 x 104) th

... Show More
View Publication Preview PDF
Crossref (2)
Crossref