Preferred Language
Articles
/
joe-794
Post-buckling Analysis of Cold-form Steel Column
...Show More Authors

For the time being, the cold-formed sections are widely used due to their simple manufacturing and construction processes. To be feasible, the strength of cold-formed columns should be determined based on their post-buckling behavior. Post-buckling relations are cumbersome and need design aids similar to those of American Iron and Steel Institute (AISI) to be applicable. These design aids have been developed to sections and materials other than those available in the local market. Therefore, this paper tries to develop a general finite element model to simulate the postbuckling behavior of cold-formed steel columns. Shell element has been used to discretize the web, flanges, and lips of the column. A linear bucking analysis with subspace Eigen value scheme has been achieved to determine the global, distortional, and local mode shapes. Subsequently, these modes have been used to generate the correspond imperfections. Finally, the modified Riks method has been used to solve the nonlinear equations of equilibrium and to a void the possible snap through phenomenon. Comparing with the traditional analyses using the effective width method and the direct strength method indicates that the finite element analysis is adequate and can be used for practical applications when dealing with local sections and materials.

Finally, different case studies with different column spans have been considered to show the behavior of the column for different slenderness ratios.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Sep 01 2024
Journal Name
Results In Engineering
Push-out test of eco-friendly steel-concrete–steel composite sections enhanced by polypropylene fibers: An experimental study and statistical analysis
...Show More Authors

Steel-concrete-steel (SCS) structural element solutions are rising due to their advantages over conventional reinforced concrete in terms of cost and strength. The impact of SCS sections with various core materials on the structural performance of composites has not yet been fully explored experimentally, and in this work, both slag and polypropylene fibers were incorporated in producing eco-friendly steel-concrete-steel composite sections. This study examined the ductility, ultimate strength, failure modes, and energy absorption capacities of steel-concrete-steel filled with eco-friendly concrete, enhanced by polypropylene fiber (PPF) to understand its impact on modern structural projects. Eco-friendly concrete was produced by the partial

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Thu Nov 21 2019
Journal Name
Journal Of Engineering
Thermal Buckling of Angle-Ply Laminated Plates Using New Displacement Function
...Show More Authors

ABSTRACT

Critical buckling temperature of angle-ply laminated plate is developed using a higher-order displacement field. This displacement field used by Mantari et al based on a constant ‘‘m’’, which is determined to give results closest to the three dimensions elasticity (3-D) theory. Equations of motion based on higher-order theory angle ply plates are derived through Hamilton, s principle, and solved using Navier-type solution to obtain critical buckling temperature for simply supported laminated plates. Changing (α2/ α1) ratios, number of layers, aspect ratios, E1/E2 ratios for thick and thin plates and their effect on thermal

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sun Oct 01 2017
Journal Name
Journal Of Engineering
Buckling Loads and Effective Length Factor for Non-Prismatic Columns
...Show More Authors

Based on a finite element analysis using Matlab coding, eigenvalue problem has been formulated and solved for the buckling analysis of non-prismatic columns. Different numbers of elements per column length have been used to assess the rate of convergence for the model. Then the proposed model has been used to determine the critical buckling load factor () for the idealized supported columns based on the comparison of their buckling loads with the corresponding hinge supported columns . Finally in this study the critical buckling factor () under end force (P) increases by about 3.71% with the tapered ratio increment of 10% for different end supported columns and the relationship between normalized critical load and slenderness ratio was g

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 01 2012
Journal Name
Journal Of Engineering
Nonlinear Finite Element Analysis of Steel Fiber Reinforced Concrete Deep Beams With and Without Opening
...Show More Authors

This paper presents a nonlinear finite element modeling and analysis of steel fiber reinforced concrete (SFRC) deep beams with and without openings in web subjected to two- point loading. In this study, the beams were modeled using ANSYS nonlinear finite element
software. The percentage of steel fiber was varied from 0 to 1.0%.The influence of fiber content in the concrete deep beams has been studied by measuring the deflection of the deep beams at mid- span and marking the cracking patterns, compute the failure loads for each deep beam, and also study the shearing and first principal stresses for the deep beams with and without openings and with different steel fiber ratios. The above study indicates that the location of openings an

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Thu Sep 15 2022
Journal Name
Journal Of Mechanical Engineering
Thermal Buckling of Laminated Plates using Modified Mantari Function
...Show More Authors

Critical buckling temperature of laminated plate under thermal load varied linearly along the thickness, is developed using a higher-order shape function which depends on a parameter ‘‘m’’, which is improved to obtain results for thin and thick plates. Laminated plates’ equations of motion are obtained using virtual work principle and solved for simply supported boundary conditions. Angle and cross laminates thermal buckled mode shapes with different E1/E2 proportion, number of plies, (α2/α1) proportion, aspect ratios, are investigated. It is observed that this shape function gives thermal buckling for thin and thick plates but with m = 0.05 that agree well with other theories and linear distribution of temperature giv

... Show More
Publication Date
Fri Jul 01 2022
Journal Name
Structures
Reliability analysis of deteriorated post-tensioned concrete bridges: The case study of Ynys-y-Gwas bridge in UK
...Show More Authors

Concrete structures are exposed to aggressive environmental conditions that lead to corrosion of the embedded reinforcement and pre-stressing steel. Consequently, the safety of concrete structures may be compromised, and this requires a significant budgets to repair and maintain critical infrastructure. Prediction of structural safety can lead to significant reductions in maintenance costs by maximizing the impact of investments. The aim of this paper is to establish a framework to assess the reliability of existing post-tensioned concrete bridges. A time-dependent reliability analysis of an existing post-tensioned involving the assessment of Ynys-y-Gwas bridge has been presented in this study. The main cause of failure of this bridge was c

... Show More
View Publication
Scopus (29)
Crossref (26)
Scopus Clarivate Crossref
Publication Date
Sun Mar 30 2003
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Mathematical Model for Multicomponent Distillation Column
...Show More Authors

View Publication Preview PDF
Publication Date
Sat Jun 30 2001
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Gas Holdup in a Bubble Column
...Show More Authors

View Publication Preview PDF
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Bubble Size Distribution In Gas-Liquid Dispersion Column
...Show More Authors

The present work investigates the effect of; superficial air velocities of: 1, 3, and 6 cm/s for two types of perforated distributor on hydrodynamic characteristic in a gas-liquid dispersion column of; air-water, and airaqueous-n-propanol solution. Bubble distribution, gas holdup, and power consumption are parameters take in consideration. Experimental work was carried out in perspex column of 8.5 cm inside diameter and 1.5 m height. Two types of bubble generator (perforated plate) were fixed at the bottom of the column; plate A (99 holes of 0.5 mm diameter and free area of 0.34%), plate B (20 holes of 1.5 mm diameter and free area of 0.62%). Photographic technique was used to measure the bubble parameters. The experimental results were

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Characteristic of Absorption with Reaction in Packed Column
...Show More Authors

View Publication Preview PDF