The service system has become a necessity of life in modern cities to be the most basic necessities of modern humans, they constitute a major base, which is based on the sustainability of life in the city and a standard measured through the degree of well-being and progress of civilized peoples and their interaction with the surrounding environment, making the services sector as a need not be an option, whenever the cities widened in population and space whenever provision of services and upgrading the quality and quantity more pressing, which made the subject of the services takes the biggest area of the trends and thinking of urban planners and those who in charge of drawing the cities policies. Considering that the processing and transfer of the water system with all its components (stations – water tanks -transmission and distribution pipelines), it is one of the most important parts of the services systems in the city. It has become a key element of the arteries of the establishment of life, but for several considerations of most important ( like storage of water and supplied with
constant pressure that balanced without wobbling at the peak daytime hours with the necessary provision of water to fight fires , as well as secured it to the sectors of city n the maintenance time of the parts of the water system or the occurrence of a failure, with the need to confirm the save and generate energy factor in renewable way). For this in whole and others, the elevated water towers cornerstone of the pillars of the water system was made that can be indispensable in providing outsourcing and distribution network , and on the grounds that the case study concerning our capital Baghdad and its suffering of the water distribution and pressure intermittent problems, this research aims to clarify the idea of the elevated water tanks have become an important actor and is a part of the process and transport of the water in the city's system, and that its presence in a thoughtful siting and storage capacities and sufficient numbers will reduce the cost of the service system and its problems and provides continuously a constant pressure is to rescue the city from the overtaking problems on the network, while avoiding the problems experienced by interruptions in the water supply process, especially in the summer, which will make the water tanks
as a necessary structures and essential elements of attractions for recreational activities and benchmarks functions within the city.
Abstract
The current research aims to reveal the extent to which all scoring rubrics data for the electronic work file conform to the partial estimation model according to the number of assumed dimensions. The study sample consisted of (356) female students. The study concluded that the list with the one-dimensional assumption is more appropriate than the multi-dimensional assumption, The current research recommends preparing unified correction rules for the different methods of performance evaluation in the basic courses. It also suggests the importance of conducting studies aimed at examining the appropriateness of different evaluation methods for models of response theory to the
... Show MoreThe research dealt with its forefront a definition of the aspects of the study and its variables, the explosive capacity and its relationship to the scoring of football for the halls and highlights the importance of these variables, and the problem of the research consisted that some players fail to score Amie because of the weak power of shots or the slow scoring, so the researchers saw studying this problem and knowing the extent of the influence of the explosive strength During the performance of the skill of scoring with five football, the study aimed to identify the relationship between the explosive strength and the skill of scoring with five football. Researchers assume that there is a statistically significant relationship between t
... Show MoreThe research presented the experience of creating a new sustainable city, and this experience of establishing an Eco-City (Environmentally friendly) is considered the first experience in Iraq. The current study stressed the importance of the need for environmental planning in the early stages of planning new cities based on realism in planning, design and implementation. Subsequently, that aims to preserve the ecosystem, which is difficult to compensate if degraded or polluted. The research incorporated environmental planning indicators within sustainable urban planning (Reliance on generating electric power that is based on clean and renewable energy sources, Availability of public t
Among several separation processes, the air flotation distinguish as remarkably high potential separation process related to its high separation efficiency and throughput, energy-efficient, simple process, cost-effective, applicable to a wide range of oily wastewater and no by-products. The current study aimed to investigate the effect of the type and concentration of surfactant on the stability of oil-water emulsion and efficiency of the separation process. For this purpose, three types of surfactant where used (anionic SDS, mixed nonionic Span 85/Tween 80, and cationic CTAB). The results demonstrated that the Span 85/Tween 80 surfactant has the best stability, and it increases with the surfactant concentration augmentation. The removal ef
... Show MoreThe aim of this investigation was to study the impact of various reaction parameters on wastewater taken from Al-Wathba water treatment plant on Tigris River in south of Baghdad, Iraq with sodium hypochlorite solution. The parameters studied were sodium hypochlorite dose, contact time, initial fecal coliform bacteria concentration, temperature, and pH. In a batch reactor, different concentrations of sodium hypochlorite solution were used to disinfect 1L of water. The amount of hypochlorite ions in disinfected water was measured using an Iodimetry test for different reaction times, whereas the Most Probable Number (MPN) test was used to determine the concentration of coliform bacteria. Total Plate Count (TPC) was utilized in this study to
... Show MoreThe financial fraud considers part of large concept to management and financial corruption, the financial fraud is appeared especially after corporate, that is Emerge agency theory, that is because recognize relationship between the management company and stakeholder, that is through group from constriction in order to block the management to fraud practice, that on the basis was choose another party in order fraud this practice and give opinion on financial statement, that consider basis decision making from stakeholder to basis the report auditor about creditability this is statement that reflect real activity for the company.The Auditor in order to lead work him Full professionalism to must using group from control Techniques, that is
... Show MoreThe financial fraud considers part of large concept to management and financial corruption, the financial fraud is appeared especially after corporate, that is Emerge agency theory, that is because recognize relationship between the management company and stakeholder, that is through group from constriction in order to block the management to fraud practice, that on the basis was choose another party in order fraud this practice and give opinion on financial statement, that consider basis decision making from stakeholder to basis the report auditor about creditability this is statement that reflect real activity for the company.The Auditor in order to lead work him Full professionalism to must using group from control Techniques, that is
... Show MoreThis study investigates the results of electrocoagulation (EC) using aluminum (Al) electrodes as anode and stainless steel (grade 316) as a cathode for removing silica, calcium, and magnesium ions from simulated cooling tower blowdown waters. The simulated water contains (50 mg/l silica, 508 mg/l calcium, and 292 mg/l magnesium). The influence of different experimental parameters, such as current density (0.5, 1, and 2 mA/cm2), initial pH(5,7, and 10), the temperature of the simulated solution(250C and 35 0C), and electrolysis time was studied. The highest removal efficiency of 80.183%, 99.21%, and 98.06% for calcium, silica, and magnesium ions, respectively, were obtained at a current de
... Show More