Experimental Study of Solar Still Under Influence of Various Conditions
...Show More Authors

In the present work, experimental tests was done to explain the effect of insulation and water level on the yield output. Linear basin, single slope solar still used to do this purpose. The test was done from May to August 2017 in Mosul City-Iraq (Latitude: Longitude: Elevation: 200 m, and  South-East face). Experimental results showed that the yield output of the still increased by 20.785% and 19.864% in case of using thermal insulation at 4cm and 5cm respectively, also the yield output decrease by 15.134% as the water level increase from 4 to 5cm, with the presence of insulation and 14.147% without it. It has been conclude that the insulation and water level play important role in the process of passive solar desalination, also the desalination process has significant value at night and cannot be ignored.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Apr 01 2016
Journal Name
Journal Of Engineering
The Use of the Artificial Damped Outrigger Systems in Tall R.C Buildings Under Seismic Loading
...Show More Authors

This paper studies the combination of fluid viscous dampers in the outrigger system to add supplementary damping into the structure, which purpose to remove the dependability of the structure to lower variable intrinsic damping. This optimizes the accuracy of the dynamic response and by providing higher level of damping, basically minimizes the wanted stiffness of the structure while at the same time optimizing the achievement.

     The modal considered is a 36 storey square high rise reinforced concrete building. By constructing a discrete lumped mass model and using frequency-based response function, two systems of dampers, parallel and series systems are studied. The maximu

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 01 2021
Journal Name
Electric Power Systems Research
Electromagnetic transient modeling of form-wound stator coils with stress grading system under PWM excitation
...Show More Authors

The insulation system of a machine coil includes several layers made of materials with different characteristics. The effective insulation design of machine coils, especially in the machine end winding, depends upon an accurate model of the stress grading system. This paper proposes a modeling approach to predict the transient overvoltage, electric field, and heat generation in machine coils with a stress grading system, considering the variation of physical properties in the insulation layers. A non-uniform line model is used to divide the coil in different segments based on material properties and lengths: overhang, stress grading and slot. The cascaded connection of chain matrices is used to connect segments for the representation of the

... Show More
Crossref (5)
Crossref
Publication Date
Tue Mar 16 2021
Journal Name
International Journal For Computational Methods In Engineering Science And Mechanics
Determination of time-dependent coefficients in moving boundary problems under nonlocal and heat moment observations
...Show More Authors

View Publication
Scopus (6)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Space-Charge Effect on the Theoretical Design of Electron Gun Operated under Zero Magnification Condition
...Show More Authors

A computational investigation is carried out in the field of charged –particle optics with the aid of numerical analysis method using the personal computer. The work is concerned with the design of electron gun with space-charge effect. The Finite element method (FEM) used in the solution of Poison's equation for determine the axial potential distribution of the two-electrode immersion lens operated under zero magnification condition , and from the solution of the paraxial ray equation the optical properties such as the focal length , spherical and chromatic aberration coefficients are determined, also a calculation of the brightness and perveance for the lens. The electrodes geometry was determined in two and three dimensi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Oct 01 2021
Journal Name
International Journal Of Geomate
NONLINEAR SIMULATION ANALYSIS OF TAPERED REINFORCED CONCRETE COLUMN (SOLID AND HOLLOW) BEHAVIOR UNDER AXIAL LOAD
...Show More Authors

View Publication
Scopus (6)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Ieee Transactions On Power Delivery
Optimal Dielectric Design of Medium Voltage Toroidal Transformer with Electrostatic Shield under Fast Front Excitation
...Show More Authors

Accurate calculation of transient overvoltages and dielectric stresses from fast-front excitations is required to obtain an optimal dielectric design of power components subjected to these conditions, which are commonly due to switching and lightning, as well as utilization of power-electronic devices. Toroidal transformers are generally used at the low voltage level. However, recent investigations and developments have explored their use at the medium voltage level. This paper analyzes the model-based improvement of the insulation design of medium voltage toroidal transformers. Lumped and distributed parameter models are used and compared to predict the transient response and dielectric stress along the transformer winding. The parameters

... Show More
Scopus (1)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue Dec 31 2024
Journal Name
International Review On Modelling And Simulations (iremos)
Vibration Analysis of Laminated Shallow Shells Under Thermal Loading Using Higher Order Shear Deformation Theory
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Finite Element Analysis of Reinforced Concrete T-Beams with Multiple Web Openings under Impact Loading
...Show More Authors

In this study, a three-dimensional finite element analysis using ANSYS 12.1 program had been employed to simulate simply supported reinforced concrete (RC) T-beams with multiple web circular openings subjected to an impact loading. Three design parameters were considered, including size, location and number of the web openings. Twelve models of simply supported RC T-beams were subjected to one point of transient (impact) loading at mid span. Beams were simulated and analysis results were obtained in terms of mid span deflection-time histories and compared with the results of the solid reference one. The maximum mid span deflection is an important index for evaluating damage levels of the RC beams subjected to impact loading. Three experi

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Wed Dec 25 2019
Journal Name
Journal Of Engineering
Corrosion Rate Optimization of Mild-Steel under Different Cooling Tower Working Parameters Using Taguchi Design
...Show More Authors

This study investigates the implementation of Taguchi design in the estimation of minimum corrosion rate of mild-steel in cooling tower that uses saline solution of different concentration. The experiments were set on the basis of Taguchi’s L16 orthogonal array. The runs were carried out under different condition such as inlet concentration of saline solution, temperature, and flowrate. The Signal-to- Noise ratio and ANOVA analysis were used to define the impact of cooling tower working conditions on the corrosion rate. A regression had been modelled and optimized to identify the optimum level for the working parameters that had been founded to be 13%NaCl, 35ᴼC, and 1 l/min. Also a confirmation run to establish the p

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Mon Jun 27 2022
Journal Name
Materials
Flexural Performance of Encased Pultruded GFRP I-Beam with High Strength Concrete under Static Loading
...Show More Authors

There is an interesting potential for the use of GFRP-pultruded profiles in hybrid GFRP-concrete structural elements, either for new constructions or for the rehabilitation of existing structures. This paper provides experimental and numerical investigations on the flexural performance of reinforced concrete (RC) specimens composite with encased pultruded GFRP I-sections. Five simply supported composite beams were tested in this experimental program to investigate the static flexural behavior of encased GFRP beams with high-strength concrete. Besides, the effect of using shear studs to improve the composite interaction between the GFRP beam and concrete as well as the effect of web stiffeners of GFRP were explored. Encasing the GFRP

... Show More
Scopus (24)
Crossref (23)
Scopus Clarivate Crossref