Thermal Simulation for Unconditioned Single Zone with Modified Roof
...Show More Authors

Roof in the Iraqi houses normally flattening by a concrete panel. This concrete panel has poor thermal properties. The usage of materials with low thermal conductivity and high specific heat gives a good improvements to the thermal properties of the concrete panel, thus, the indoor room temperature improves. A Mathcad program based on a mathematical model employing complex Fourier series built for a single room building. The model input data are the ambient temperature, solar radiation, and sol-air temperature, which have been treated as a periodic function of time. While, the room construction is constant due to their materials made of it, except the roof properties are taken as a variable generated practically from the improved mixing ratios.The result showed that using concrete panel with components (cement, sand, coarse aggregate, wood ash and Alabaster aggregates) with a ratio (1:1:2:1:1) and 3-plastic layer denoted by roof No.4, gives the best improvement of the thermal performance for the building. Where, the thermal conductivity is reduced by 42% and the specific heat increased by 41.2% compared to the traditional concrete panel mixing ratio denoted by roof No.1. Also, the mechanical properties are agreed with the Iraqi standards No. 1107 on 2002.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri May 01 2015
Journal Name
Journal Of Engineering
Experimental Study of the Thermal Performance of Flat Plate Solar Collectors Array by Different Connection Configurations
...Show More Authors

The current research illustrates experimentally the effect of series and parallel connection (Z-I Configurations) of flat plate water solar collectors array on the thermal performance of closed loop solar heating system. The study includes the effect of changing the water flow rate on the thermal efficiency. The results show that, the collector's efficiency in series connection is higher than the parallel connection within flow rate level less than (100) ℓ/hr. Moreover, the collector efficiency in parallel connection of (I-Configurations) is more than the (Z- Configurations) with increasing the water flow rate .The maximum daily efficiency for parallel (I-Configurations) and (Z- Configurations) are (55%) and (51%) at w

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
Plasma Medicine
Thermal Effect of Laser on Silver Nanoparticles Synthesized by the Cold Plasma Method on Cancer Cells
...Show More Authors

In this study, silver nanoparticles (AgNPs) were synthesized using a cold plasma technique and a plasma jet. They were then used to explore how photothermal treatment may be used to treat lung cancer (A549) and normal cells (REF) <i>in vitro</i>. The anti-proliferative activity of these nanoparticles was studied after A549 cells were treated with (AgNPs) at various concentrations (100&#37;, 50&#37;, or 25&#37;) and exposure times (6 or 8 min) of laser after 1 h or 24 h from exposed AgNPs. The highest growth inhibition for cancer cells is (75&#37;) at (AgNPs) concentration (100&#37;) and the period of exposure to the laser is (8 min). Particle size for the prepared samples varied according to the diameter o

... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Mon May 01 2017
Journal Name
Journal Of The Mechanical Behavior Of Biomedical Materials
Bioactivity, cytocompatibility and thermal properties of experimental Bioglass-reinforced composites as potential root-canal filling materials
...Show More Authors

To evaluate the bioactivity and the cytocompatibility of experimental Bioglass-reinforced polyethylene-based root-canal filling materials. The thermal properties of the experimental materials were also evaluated using differential scanning calorimetry, while their radiopacity was assessed using a grey-scale value (GSV) aluminium step wedge and a phosphor plate digital system. Bioglass 45S5 (BAG), polyethylene and Strontium oxide (SrO) were used to create tailored composite fibres. The filler distribution within the composites was assessed using SEM, while their bioactivity was evaluated through infrared spectroscopy (FTIR) after storage in simulated body fluid (SBF). The radiopacity of the composite fibres and their thermal properties were

... Show More
View Publication Preview PDF
Crossref (29)
Crossref
Publication Date
Mon Mar 07 2022
Journal Name
Journal Of Inorganic And Organometallic Polymers And Materials
Mechanical Characteristics and Thermal Stability of Hybrid Epoxy and Acrylic Polymer Coating/Nanoclay of Various Thicknesses
...Show More Authors

View Publication
Crossref (28)
Crossref
Publication Date
Thu Jun 07 2018
Journal Name
Applied Physics A
Effect of incorporation of conductive fillers on mechanical properties and thermal conductivity of epoxy resin composite
...Show More Authors

View Publication
Crossref (58)
Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Theoretical study to find the thermal stress and strain generated in the Wood silica using lasers
...Show More Authors

In this research study theory to find the stress and emotion gases in the glass as a result of exposure to pulses of the laser beam has been the study using vehicles three major on-system axes cylindrical (r, 0, z), where I took three models of glass silica glass soda glass fused and shedtwo types of lasers where the study showed that the thermal stresses and emotions ...

View Publication Preview PDF
Publication Date
Thu Oct 29 2020
Journal Name
The 11th International Renewable Energy Congress (irec 2020)
Thermal efficiency Optimization of the evacuated tube solar water heater system by using mirror flat reflector
...Show More Authors

In this paper a comparison of the experimental of evacuated tube solar water heater systems with and without mirror flat reflector. The aim of using the reflector to improve thermal efficiency, and the data gathered which are (temperature, solar irradiation and time) for three days were compared. the results from compared data the temperature lower increase in evacuated tube solar water heater system without reflector than the temperature increase in evacuated tube solar water heater system with reflector .The results show (53, 39, 35) % for three days respectively that the evacuated tube solar water heater system with reflector has higher thermal efficiencies than the results (47, 28, 30) % for three days respectively thermal efficiencies

... Show More
View Publication
Crossref (4)
Crossref
Publication Date
Fri Aug 20 2021
Journal Name
Open Access Macedonian Journal Of Medical Sciences
Autogenous Onlay Graft with Compression Plate for Treatment of Persistent Humeral Shaft Aseptic Non-union with Failed Previous Surgery
...Show More Authors

BACKGROUND: The humeral shaft fractures have a good rate of union, despite this fact, still there is a significant rate of nonunion after nonoperative treatment and more often after operative treatment. AIM: The aim of the study is to evaluate the autogenous onlay graft with compression plate for treatment of persistent humeral shaft non-union with failed previous surgery both radiological and functional outcome. MATERIALS AND METHODS: A prospective study on twenty patients having persistent aseptic non-union age between 20 and 60 years old, after failed surgical treatment of fractures humeral shaft in Al-Zahra teaching and Al-Kindy teaching hospitals, while infected nonunion, diabetes mellitus, secondary metastasis, smoking, a

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Jun 04 2020
Journal Name
Journal Of Petroleum Exploration And Production Technology
Re-assessment and tune-up gas condensate reservoir potential in Northern Iraq using material balance and reservoir simulation result techniques
...Show More Authors
Abstract<p>The main parameter that drives oil industry contract investment and set up economic feasibility study for approving field development plan is hydrocarbon reservoir potential. So a qualified experience should be deeply afforded to correctly evaluate hydrocarbons reserve by applying different techniques at each phase of field management, through collecting and using valid and representative data sources, starting from exploration phase and tune-up by development phase. Commonly, volumetric calculation is the main technique for estimate reservoir potential using available information at exploration stage which is quite few data; in most cases, this technique estimate big figure of reserve. In this study</p> ... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Sun Nov 01 2015
Journal Name
Journal
Topical 40% Loranthus europaeus Ointment Versus Topical 25% Podophyllin Solution in the Treatment of Acute Cutaneous Leishmaniasis (Single Blinded, Therapeutic, Comparative study)
...Show More Authors

KE Sharquie, AA Noaimi, BAM Saleh, 2015

View Publication