Preferred Language
Articles
/
joe-433
Resistance to Moisture Damage of Recycled Asphalt Concrete Pavement
...Show More Authors

Recycled asphalt concrete mixture are prepared, artificially aged and processed in the laboratory to maintain the homogeneity of recycled asphalt concrete mixture gradation, and bitumen content. The loose asphalt concrete mix was subjected to cycle of accelerated aging, (short –term aging) and the compacted mix was subjected to (long -term aging) as per Super-pave procedure. Twenty four Specimens were constructed at optimum asphalt content according to Marshall Method. Recycled mixture was prepared from aged asphalt concrete using recycling agent (soft asphalt cement blended with silica fumes) by (1.5%) weight of mixture as recycling agent content. The effect of recycling agent on aging after recycling process behavior of asphalt concrete was determine. Aged specimens after recycling process were prepared by subjecting the recycled asphalt concrete to accelerated aging and tested for resistance to moisture damage. The improvement in the resistance to moisture damage of aged mixture after recycling with (soft asphalt cement blended with silica fumes) was 76.17% as compared to the corresponding aged mixture before recycling process. The ITS for unconditioned specimens for aged after recycling process mixture was less than reference by 67.1%, and less than that of aged before recycling process mixtures by 64.1%.

 

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Engineering
Strengthening of GFRP Reinforced Concrete Slabs with Openings
...Show More Authors

Using fiber-reinforced polymer (FRP) could effectively improve the strength and endurance of reinforced concrete (RC) constructions. This study evaluated the flexural behavior of one-way concrete slabs with openings reinforced with glass fiber-reinforced polymers (GFRP) bars. It strengthened using carbon fiber-reinforced polymer (CFRP) sheets around the openings. The experimental program of this study is adopted by casting and testing four one-way concrete slabs with dimensions of (150*750*2650) mm. These slabs are divided into two groups based on whether they were strengthened or un-strengthened. For each group, two different openings (either one rectangular or two square) measured 250*500 mm and 250*250 mm, respective

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Mon Jun 05 2023
Journal Name
Journal Of Engineering
Prediction of Compressive Strength of Reinforced Concrete Structural Elements by Using Combined Non-Destructive Tests
...Show More Authors

This research is devoted to investigate relationship between both Ultrasonic Pulse Velocity and Rebound Number (Hammer Test) with cube compressive strength and also to study the effect of steel reinforcement on these relationships.
A study was carried out on 32 scale model reinforced concrete elements. Non destructive testing campaign (mainly ultrasonic and rebound hammer tests) made on the same elements. About 72 concrete cubes (15 X 15 X15) were taken from the concrete mixes to check the compressive strength.. Data analyzed.Include the possible correlations between non destructive testing (NDT) and compressive strength (DT) Statistical approach is used for this purpose. A new relationships obtained from correlations results is give

... Show More
View Publication Preview PDF
Crossref (10)
Crossref
Publication Date
Fri Sep 01 2017
Journal Name
Journal Of Engineering
Fire Flame Influence on the Behavior of reinforced Concrete Beams Affected by Repeated Load
...Show More Authors

The influence and hazard of fire flame are one of the most important parameters that affecting the durability and strength of structural members. This research studied the influence of fire flame on the behavior of reinforced concrete beams affected by repeated load. Nine self- compacted reinforced concrete beams were castellated, all have the same geometric layout (0.15x0.15x1.00) m, reinforcement details and compressive strength (50 Mpa). To estimate the effect of fire flame disaster, four temperatures were adopted (200, 300, 400 and 500) oC and two method of cooling were used (graduated and sudden). In the first cooling method, graduated, the tested beams were leaved to cool in air while in the second method, sudden, water splash was use

... Show More
Publication Date
Thu Jan 30 2014
Journal Name
Al-kindy College Medical Journal
THE PREVALENCE AND ANTIMICROBIAL RESISTANCE OF PSEUDOMONAS SPECIES IN PATIENTS WITH CHRONIC SUPPURATIVE OTITIS MEDIA
...Show More Authors

Background: Chronic suppurative otitis media (CSOM) is the result of aninitial episode of acute otitis media and is characterized by a persistent discharge from the middle ear through a tympanic perforation for at least 2 weeks duration. It is an important cause of preventable hearing loss, particularly in the developing world.Methods. 1. To get an overview on the bacterial ear infection profile in general 2. To assess the antibiotic resistance of Pseudomonal infection (PS) particularly since it is usually the commonest infection to cause otitis media and the most difficult to treat due to the problem of multi drug resistance... A cross sectional study was done which included 405 patient of CSOM patients196 (48%) case were males ,209 (52

... Show More
View Publication Preview PDF
Publication Date
Mon May 09 2022
Journal Name
مجلة علوم ديالى
The expression of PmrA gene in Acinetobacter baumannii bacteria that is responsible for Colistin resistance
...Show More Authors

Publication Date
Sun Sep 06 2009
Journal Name
Baghdad Science Journal
Bacteremia in Ibn Al-Baladi hospital in Baghdad; Incidence etiology and antibiotic resistance of pathogens
...Show More Authors

60 cases of Bacteremia were documented at Ibn Al-Baladi hospital during 6 months (1-1-2002 to 1-7-2002), with an incidence of 5.2 were gram-negative organisms and most common one was Salmonella and Klebsiella. Incidence was significantly higher in male than female .Antimicrobial sensitivity tests revealed that isolated bacteria are with multiple drug resistance to commonly used antimicrobial agents. Salmonella showed high resistance to cephaloxin, co-trimoxazole and amoxicillin and also Klebsiella showed resistance to cephaloxin and amoxicillin.

View Publication Preview PDF
Crossref
Publication Date
Tue Jan 18 2022
Journal Name
مجلة ديالى للعلوم الصرفة
Study the gene expression of aacC1 gene in Acinetobacter baumannii that responsible for Aminoglycoside resistance
...Show More Authors

Publication Date
Tue Jun 30 2015
Journal Name
Al-kindy College Medical Journal
The prevalence and antimicrobial resistance of Pseudomonas species in patients with chronic suppurative otitis media
...Show More Authors

Background: Chronic suppurative otitis media (CSOM) is the result of an initial episode of acute otitis media and is characterized by a persistent discharge from the middle ear through a tympanic perforation for at least 2 weeks duration. It is an important cause of preventable hearing loss, particularly in the developing world.Objective: To get an overview on the bacterial ear infection profile in general and to assess the antibiotic resistance of Pseudomonal infection (PS) particularly since it is usually the commonest infection to cause otitis media and the most difficult to treat due to the problem of multi drug resistance..Methods: A cross sectional study was done which included 405 patients of CSOM patients, 196 (48%) case were mal

... Show More
View Publication Preview PDF
Publication Date
Thu Nov 01 2018
Journal Name
Journal Of Biological Sciences
Investigation of Plasmid-Associated Fluoroquinolone Resistance in Nosocomial Pseudomonas aeruginosa Isolated from Infected Burn Wounds
...Show More Authors

View Publication
Scopus (6)
Crossref (1)
Scopus Crossref
Publication Date
Fri Apr 01 2016
Journal Name
Journal Of Engineering
Experimental Behavior of Steel-Concrete-Steel Sandwich Beams with Truss Configuration of Shear Connectors
...Show More Authors

This paper presents experimentally a new configuration of shear connector for Steel-Concrete-Steel (SCS) sandwich beams that is derived from truss configuration. It consists of vertical and inclined shear connectors welded together and to cover steel plates infilled with concrete. Nine simply supported SCS beams were tested until the failure under a concentrated central load (three- point bending). The beams were similar in length (1100mm), width (100mm), and the top plate thickness (4mm). The test parameters were; beam thickness (150, 200, 250, and 300mm), the bottom plate thickness (4, and 6mm), the diameter of the shear connectors (10, 12, and 16mm), and the connector spacing (100, 200, and 250mm). The test results sh

... Show More
View Publication Preview PDF