Preferred Language
Articles
/
joe-351
Dynamic Analysis of Fluid – Structure Interaction of Axial Fan System
...Show More Authors

Fluid-structure interaction method is performed to predict the dynamic characteristics of axial fan system. A fluid-structure interface physical environment method (monolithic method) is used to couple the fluid flow solver with the structural solver. The integration of the three-dimensional Navier-Stokes equations is performed in the time Doman, simultaneously to the integration of the three dimensional structural model. The aerodynamic loads are transfer from the flow to structure and the coupling step is repeated within each time step, until the flow solution and the structural solution have converged to yield a coupled solution of the aeroelastic set of equations. Finite element method is applied to solve numerically the Navier-Stockes equations coupled with the structural equations The first ten eigenvalue (natural frequency), the first ten eigenvector (mode shape) and effective stress for each part of a rotor system and complete system assembly are predicted.

The validity of the predicted dynamic characteristics of duct fan system was confirmed experimentally by investigating geometrically similar fan system test rig. Good agreement of dynamic characteristics is observed between experimental and numerical results.

 

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 06 2011
Journal Name
Baghdad Science Journal
Histological Structure of the Integument in Mastacembelus mastacembelus (Solander)
...Show More Authors

The histological structure of integument in Mastacembelus mastacembelus have been investigated from skin fragments cut from nine regions at body surface. The results revealed that the integument of the fish investigated comprises three principal layers- the epidermis, the dermis (corium) and the subcutis-All the three principal layers may further be divided into secondary layers according to the function performed by their cells. The epidermis may further divided into three layers- the outermost epithelial coverage, the middle layer and the basal layer (stratum germinatiuum)-The dermis consists of a relatively thin upper layer of loose vascular connective tissue called the stratum laxum and a thick lower compact layer- the stratum compactu

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Oct 03 2021
Journal Name
Journal Of Discrete Mathematical Sciences And Cryptography
Analysing the structure of A4-graphs for Mathieu groups
...Show More Authors

View Publication
Scopus (6)
Scopus Clarivate Crossref
Publication Date
Fri Mar 30 2001
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Construction of Nomograms Describing the Effect of Different Variables on the Behavior of a KCl/Polymer Drilling Fluid
...Show More Authors

View Publication Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
2018 International Conference On Advanced Science And Engineering (icoase)
Real-Time Face Tracking and Recognition System Using Kanade-Lucas-Tomasi and Two-Dimensional Principal Component Analysis
...Show More Authors

View Publication
Scopus (16)
Crossref (8)
Scopus Crossref
Publication Date
Sun Feb 10 2019
Journal Name
Iraqi Journal Of Physics
Investigation of the nuclear structure of 84-108Mo isotopes using Skyrme-Hartree-Fock method
...Show More Authors

Over the last few decades the mean field approach using selfconsistent
Haretree-Fock (HF) calculations with Skyrme effective
interactions have been found very satisfactory in reproducing
nuclear properties for both stable and unstable nuclei. They are
based on effective energy-density functional, often formulated in
terms of effective density-dependent nucleon–nucleon interactions.
In the present research, the SkM, SkM*, SI, SIII, SIV, T3, SLy4,
Skxs15, Skxs20 and Skxs25 Skyrme parameterizations have been
used within HF method to investigate some static and dynamic
nuclear ground state proprieties of 84-108Mo isotopes. In particular,
the binding energy, proton, neutron, mass and charge densities

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Oct 01 2012
Journal Name
Iraqi Journal Of Physics
The effect of the etching time on the electrical properties of nano structure silicon
...Show More Authors

This work presents the study of the dark current density and the capacitance for porous silicon prepared by photo-electrochemical etching for n-type silicon with laser power density of 10mw/cm2 and wavelength (650nm) under different anodization time (30,40,50,60) minute. The results obtained from this study shows different chara that different characteristic of porous diffecteristics for the different porous Silicon layers.

View Publication Preview PDF
Publication Date
Sun Nov 01 2015
Journal Name
Journal Of Engineering
Heat Transfer Characteristics of a Fluid Flow in Multi Tube Heat Exchanger Fitted with Perforated Fins
...Show More Authors

The heat transfer and flow resistance characteristics for air flow cross over circular finned tube heat exchanger has been studied numerically and experimentally. The purpose of the study was to improve the heat transfer characteristics of an annular finned-tube heat exchanger for better performance. The study has concentrated on the effect of the number of perforations and perforations shapes on the heat transfer and pressure drop across a staggered finned tube heat exchanger. The Numerical part of present study has been performed using ANSYS Fluent 14.5 using SST Turbulent model, while the experimental study consist from a test rig with different models of heat exchangers and all required measurement devices were build

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 01 2020
Journal Name
Plant Archives
Development, validation, and pharmaceutical dosage forms application of hydrophilic interaction chromatography assay for the quantification of theophylline
...Show More Authors

The present work establishes and validates HILIC strategies simple, accurate, exact and precise in pure form and inpharmaceutical dosage for separating and determining theophylline. These methods are developed on HILIC theophyllineseparation in columns ZIC2 and ZIC3. The eluent was prepared by mixing buffer (20% sodium acetate-40 mM, pH 5.5), 80%acetonitrile. The flow rate is 0.8 mL/min, with gradient elution and UV detection at 270 nm. In the ZIC2 and ZIC3 columns oftheophylline determining, the concentration range was 0.01-4μg.ml-1. The lower limit of detection and quantification fortheophylline were determined as 0.130, 0.190 μg.ml-1 and accuracy were 99.70%, 99.58% on ZIC2 and ZIC3, respectively. TheHILIC methods developed and validat

... Show More
Publication Date
Wed Jun 01 2022
Journal Name
Political Sciences Journal
Transformation in International Polar System: Study of the future of the nonpolar system
...Show More Authors

The study of the future of the international system currently appears, according to scientific data and existing facts in light of the emergence of international actors from non-states and international informal institutions, to be heading towards a non-polarity system and this trend is fueled by many variables to reduce polarity, and it is expected in the future that the international system will turn into a non-polarity.

 

View Publication Preview PDF
Crossref
Publication Date
Sun Nov 26 2017
Journal Name
Journal Of Engineering
The Dynamic Behavior of Water Flowing Through Packed Bed of Different Particle Shapes and Sizes
...Show More Authors

An experimental study was conducted on pressure drop of water flow through vertical cylindrical packed beds in turbulent region and the influence of the operating parameters on its behavior. The bed packing was made of spherical and non-spherical particles (spheres, Rasching rings and intalox saddle) with aspect ratio range 3.46  D/dp  8.486 obtaining bed porosities 0.396 0.84 and Reynolds number 1217  21758. The system is consisted of 5 cm inside diameter Perspex column, 50 cm long; distilled water was pumped through the bed with flow rate 875, 1000, 1125, 1250,1375 and 1500 l/h and inlet water temperature 20, 30, 40 and 50 ˚C. The packed bed system was monitored by using LabVIEW program, were the result

... Show More
View Publication Preview PDF