Preferred Language
Articles
/
joe-321
Bit Performance in Directional Oil Wells
...Show More Authors

This work aims to analyze and study the bit performance in directional oil wells which leads to get experience about the drilled area by monitoring bit performance and analyzing its work. This study is concerned with Rumaila Oil Field by studying directional hole of one oil well with different angles of inclination. Drilling program was used in order to compare with used parameters (WOB, RPM and FR).in those holes. The effect of the drilling hydraulic system on the bit performance was studied as well as the hydraulic calculation can be done by using Excel program. This study suggests method which is used to predict the value of penetration rate by studying different formation type to choose the best drilling parameters to drill each formation. Finally, the main aim of this research is to have the benefit from the past well drilling data to drill new wells without needing new drilling program for each well, also knowing the problems of each formation to avoid them as soon as possible through drilling the new wells, which will improve the bit performance.

 

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jan 02 2017
Journal Name
Al-academy
The semiology of culture and the sign variable in a theatre performance: Iraqi theatre as an example
...Show More Authors

The culture of theatre performance has a vital role in the process of reading the linguistic and visual signs of the performance. And the process of transforming a theatre performance from its original context into a new hosting cultural context starts from the actual reading of the text. Directors derives their new signs out of his personal culture, depending on the society where they lives and the culture that forms the social conventions, traditions and beliefs. The text is usually written within its own historical and temporal culture. The process of its production usually takes it away from its original culture, when it interprets the codes of the original writer and their visual and linguistic signs and instils new alternative sign

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Aug 01 2015
Journal Name
Journal Of Engineering
An Investigation into Thermal Performance of Closed Wet Cooling Tower for Use with Chilled Ceilings in Buildings
...Show More Authors

Chilled ceilings systems offer potential for overall capital savings. The main aim of the present research is to investigate the thermal performance of the indirect contact closed circuit cooling tower, ICCCCT used with chilled ceiling, to gain a deeper knowledge in this important field of engineering which has been traditionally used in various industrial & HVAC systems. To achieve this study, experimental work were implemented for the ICCCCT use with chilled ceiling. In this study the thermal performances of closed wet cooling tower use with chilled ceiling is experimentally and theoretically investigated. Different experimental tests were conducted by varying the controlling parameters to investigate their effects

... Show More
View Publication Preview PDF
Publication Date
Tue Aug 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
Measure the level of banking performance in accordance with the e-marketing and total quality management requirements
...Show More Authors

Acquires Find importance of the overall quality and e-marketing management have become important factors in evaluating the performance of banks, which are related to the life of the community intimately, so it is important that the banks applying comprehensive quality and e-marketing management requirements in order to maintain their performance and determine their level, as well as the manifest importance of research in part, practical linking the requirements of total quality management and banking performance on the one hand and between the e-marketing and performance banking on the other hand, through the provision of scientific bases that can be based on the banks in question, as it kicks off the research problem in that mos

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Mar 29 2021
Journal Name
Journal Of Engineering
Experimental Investigation of Thermal Performance of Aluminum Foil Coated with Polyester in a Direct Evaporative Cooling System
...Show More Authors

An experimental study was carried out for an evaporative cooling system in order to investigate the effect of using an aluminum pad coated with fabric polyester. In the present work, it was considered to use a new different type of cooling medium and test its performance during the change in the wet-bulb temperature and dry-bulb temperature of the supply air outside of the pad, the relative humidity of the supply air, the amount of air supplied (300-600) CFM and also the change of the amount of circulated water (1.75, 2.5, 4.5) liter per minute. A decrease in the WBT of the air was obtained, whereas the WBT of the air entering the pad was 26.5 . In contrast, the WBT of the outside air had reached 23  even though eva

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Journal Of The College Of Education For Women
The role of thclimate in the development of the performance of the administrative bodies of sports clubs
...Show More Authors

The role of the climate in the development of the performance of the administrative bodies of sports clubs

View Publication Preview PDF
Publication Date
Thu Feb 01 2024
Journal Name
Journal Of Engineering
Performance Evaluation of Two Stages Parallel Flow Indirect Evaporative Cooling with Aspen Pads in Baghdad Climate Conditions
...Show More Authors

This study delves into the realm of advanced cooling techniques by examining the performance of a two-stage parallel flow indirect evaporative cooling system enhanced with aspen pads in the challenging climate of Baghdad. The objective was to achieve average air dry bulb temperatures (43 oC) below the ambient wet bulb temperatures (24.95 oC) with an average relative humidity of 23%, aiming for unparalleled cooling efficiency. The research experiment was carried out in the urban environment of Baghdad, characterized by high temperature conditions. The investigation focused on the potential of the two-stage parallel flow setup, combined with the cooling capability of aspen pads, to surpass the limitat

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jan 24 2017
Journal Name
Journal Of Madenat Alelem College
Effect of Prey Type on Relationship between Reproductive Performance and Female's Age in Macrocyclops albidus (Jurine 1820)
...Show More Authors

The present study was conducted to investigate effect of prey type on the relationship between age of females of Macrocyclops albidus and reproductive performance, which included each of mean number of nauplii, age at first brood, and age at first clutch. Results revealed that the correlation coefficient between the age at first brood and clutch and age of females fed on Artemia was significant P <0.05, being 0.65 and 0.81 respectively, while the correlations were not significant P>0.05 in females fed on mosquito larvae (Culex quinquefasciatus) and Paramecium nauplii. It was also found that the correlation coefficients between mean number of the nauplii and longevity in M. albidus were significant P<0.05 whereas, the correlations were not s

... Show More
Publication Date
Tue Aug 16 2022
Journal Name
Heat Transfer
Experimental study on thermo‐hydraulic performance of metal foam twisted tape in a double pipe heat exchanger
...Show More Authors
Abstract<p>A recent study compared experimentally the hydraulic and thermal activity of twisted tape inserts for two types, metal foam twisted tape (MFTT) and traditional twisted tape (TTT), in a double pipe heat exchanger. The investigation goal of the innovatively designed MFTT is to enhance the heat transfer process, which provides a higher thermal enhancement factor over those of TTT under the same conditions. Heat transfer activity in terms of Nusselt number (<italic>Nu</italic>) and Nusselt number ratio (<italic>Nu</italic>/<italic>Nu</italic><sub>o</sub>) as the heat exchanger equipped with the proposed MFTT and TTT inserts with various tape‐twist ratios (<i></i></p> ... Show More
View Publication
Scopus (8)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Engineering
Modeling and Simulation of Solar Module performance using Five Parameters Model by using Matlab in Baghdad City
...Show More Authors

This work presents the modeling of the electrical response of monocrystalline photovoltaic module by using five parameters model based on manufacture data-sheet of a solar module that measured in stander test conditions (STC) at radiation 1000W/m² and cell temperature 25 . The model takes into account the series and parallel (shunt) resistance of the module. This paper considers the details of Matlab modeling of the solar module by a developed Simulink model using the basic equations, the first approach was to estimate the parameters: photocurrent Iph, saturation current Is, shunt resistance Rsh, series resistance Rs, ideality factor A at stander test condition (STC) by an ite

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu May 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Study of Effect of Diesel Fuel Energy Rate in Duel Fuel on Performance of Compression Ignition Engine
...Show More Authors

The aim of this work is to study the effect of diesel fuel percentage on the combustion processes in compression ignition engine using dual – fuel (diesel and LPG).

 The brake thermal efficiency increased with the increase of diesel fuel rate at low loads, and decreased when load increased. To get sufficient operation in engine fueled with dual fuel, it required sufficient flow rate of diesel fuel, if the engine fueled with insufficient diesel fuel erratic operation with miss fire cycles presented.

Dual-fuel operation at part load showed higher specific fuel consumption than straight diesl operation. At full loads, brake specific fuel consumption of duel fuel engine approaches that for diesel fuel values.

View Publication Preview PDF