Preferred Language
Articles
/
joe-3038
REMOVAL OF COPPER ION FROM WASTEWATER BY FLOTATION
...Show More Authors

Several industrial wastewater streams may contain heavy metal ions, which must be effectively removal
before the discharge or reuse of treated waters could take place. In this paper, the removal of copper( II)
by foam flotation from dilute aqueous solutions was investigated at laboratory scale. The effects of
various parameters such as pH, collector and frother concentrations, initial copper concentration, air flow
rate, hole diameter of the gas distributor, and NaCl addition were tested in a bubble column of 6 cm inside
diameter and 120 cm height. Sodium dodecylsulfate (SDS) and Hexadecyl trimethyl ammonium bromide
(HTAB) were used as anionic and cationic surfactant, respectively. Ethanol was used as frothers and the
optimal removal conditions have been established. Successful removals about (98%) and (76%) could be
achieved for copper ions with SDS and HTAB, respectively. Copper removal reached about 80% under
the optimum conditions at low pH; at high pH it became as high as 98% probably due to the contribution
from the flotation of precipitated copper. It was found that the presence of NaCl in the solution reduced
the recoveries. Adding ethanol at 1% concentration increased the removal efficiency. From the results the
rate of flotation was found to be first order.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 04 2018
Journal Name
Baghdad Science Journal
Biosorption of Safranin-O from Aqueous Solution by Nile Rose Plant (Eichhornia crassipes)
...Show More Authors

In this work Aquatic plant (Nile rose) was used to study adsorption of industrial dye (safranin-O from aqueous solution within several operation conditions. The dried leaves of Nile rose plant were used as adsorbents safranin-O from aqueous solution after different activations such as wet and dry enhancements. The data show increasing in dye solution removal percentage for both activation methods of the adsorbent and also dye removal percentage that was obtained by using adsorbent without any treatment with the progress contact time. The dye removal percentages at equilibrium time 40 minutes were 88.7% at non-activation, 92.3% at thermal activation, and 98.3% at acidic activation. The samples adsorbents before and after adsorption which wer

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Baghdad Science Journal
Removing Toxic Dyes from Aqueous Medium by Trichoderma-Graphain Oxide Aerogel
...Show More Authors

Toxic dyes are commonly discharged into waste waters and dyes are extensively used in the textile industry so it is necessary to find out efficient and eco-friendly method for treating waste waters resulting from industrial effluences. To achieve this aim the fungus Trichoderma sp. is employed into two lines: first line was self – immobilized fungal pellets in (Czapek – Dox medium) to adsorbs two dyes crystal violet, congo red by concentrations 0.01, 0.02, 0.03, 0.04, 0.05, 0.06 mg/L to both dyes, PH 2, room temperature with shaker in ( hrs.2,hrs.4,hrs.24) , by Uv- Visible spectrum . the removal efficiency of 0.05 mg/L crystal violet by Trichoderma sp was 96%. but there was no remova

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (3)
Scopus Crossref
Publication Date
Wed Mar 18 2020
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Copper(II) using 2,2[O-Tolidine-4,4-bis azo]bis[4,5-diphenyl imidazole](MBBAI)
...Show More Authors

            Spectrophotometric method was developed for the determination of copper(II) ion. Synthesized (2,2[O-Tolidine-4,4-bis azo]bis[4,5-diphenyl imidazole]) (MBBAI) was used as chromogenic reagent at pH=5. Various factors affecting complex formation, such as, pH effect, reagent concentration, time effect and temperature effect, have been considered and studied. Under optimum conditions concentration ranged from (5.00-80.00) µg/mL of copper(II) obeyed Beer`s Low. Maximum absorption of the complex was 409nm with molar absorpitivity 0.127x104 L mol-1 cm-1. Limit of detection(LOD) and Limit of quantification were 1.924 and 6.42 μg/mL, respectively.

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Mon Jun 01 2020
Journal Name
Heliyon
Electrocoagulation treatment of high saline oily wastewater: evaluation and optimization
...Show More Authors

The present work provides to treat real oily saline wastewater released from drilling oil sites by the use of electrocoagulation technique. Aluminum tubes were utilized as electrodes in a concentric manner to minimize the concentrations of 113400 mg TDS/L, 65623 mg TSS/L, and the ions of 477 mg HCO3/L, 102000 mg Cl/L and 5600 mg Ca/L presented in real oily wastewater under the effect of the operational parameters (the applied current and reaction time) by making use of the central composite rotatable design. The final concentrations of TDS, TSS, HCO3, Cl, and Ca that obtained were 93555 ppm (17.50%), 11011 ppm (83.22%), 189ppm (60.38%), 80000ppm (22%), and 4200 ppm (25%), respectively, under the optimum values of the operational parameters

... Show More
View Publication
Scopus (79)
Crossref (63)
Scopus Clarivate Crossref
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Serum ceruloplasmin ,copper and iron levels as a risk factors for coronary heart diseases(CHD)
...Show More Authors

Ceruloplasmin (Cp) is one of the acute phase protein, in this review ,we studied the level of ceruloplasmin with copper (Cu) and iron in 90 patients with coronary heart diseas ( those patients are divided into three groups, whom are stable angina , unstable angina and myocardial infarction compared with 30 healthy volunteers) and the roles of them as diagnostic and prognostic tools.The diagnosis was attend by a clinical examination carried out by the consult medical staff in Ibn AL-Nafis hospital. The result: ceruloplasmin recorded a significantly(p<0.05)higher level in all patient groups compared with the control, so this result supports the hypothesis that a high serum ceruloplasmin level is a risk factor for coronary heart di

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
Forward-Reverse Osmosis Processes for Oily Wastewater Treatment
...Show More Authors

In this study, the feasibility of Forward–Reverse osmosis processes was investigated for treating the oily wastewater. The first stage was applied forward osmosis process to recover pure water from oily wastewater. Sodium chloride (NaCl) and magnesium chloride (MgCl2) salts were used as draw solutions and the membrane that was used in forward osmosis (FO) process was cellulose triacetate (CTA) membrane. The operating parameters studied were: draw solution concentrations (0.25 – 0.75 M), oil concentration in feed solution (FS) (100-1000 ppm), the temperature of FS and draw solution (DS) (30 - 45 °C), pH of FS (4-10) and the flow rate of both DS and FS (20 - 60 l/h). It was found that the water flux and oil concentration in FS increas

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Mar 11 2019
Journal Name
Baghdad Science Journal
Effects of Discharge Current and Target Thickness in Dc-Magnetron Sputtering on Grain Size of Copper Deposited Samples
...Show More Authors

A study of the effects of the discharge (sputtering) currents (60-75 mA) and the thickness of copper target (0.037, 0.055 and 0.085 mm) on the prepared samples was performed. These samples were deposited with pure copper on a glass substrate using dc magnetron sputtering with a magnetic flux density of 150 gauss at the center. The effects of these two parameters were studied on the height, diameter, and size of the deposition copper grains as well as the roughness of surface samples using atomic force microscopy (AFM).The results of this study showed that it is possible to control the specifications of copper grains by changing the discharge currents and the thickness of the target material. The increase in discharge curre

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Desalination And Water Treatment
Combination of the artificial neural network and advection-dispersion equation for modeling of methylene blue dye removal from aqueous solution using olive stones as reactive bed
...Show More Authors

Scopus (15)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Sun Feb 25 2024
Journal Name
Iraqi Journal Of Agricultural Sciences
THE EFFICIENCY OF GUM-SILICA CMPOSITE FOR REMOVING OF WASTEWATER TURBIDITY
...Show More Authors

A novel mixed natural coagulant has been developed to remove sewage pollutants and heavy metals from Qanat- al- Jayesh by using low cost adsorbent natural materials. In these materials, significant interaction contains Arabic gum mixed with extracted silica from rice husk ash (natural coagulants) by the Batch device approach, using two variables, pH values ranging from 5-8 and contact times between 0.25-5 hrs. All wastewater samples were collected after treatment by adsorbents and examined for determination of residual heavy metal concentrations: Pb, Ni, Zn and Cu by atomic absorption spectroscopy (AAS), turbidity, pH, total dissolved salts (TDS), electrical conductivity (EC) and total salinity (TS). The results obtained indicate Th

... Show More
View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Sun Feb 25 2024
Journal Name
Iraqi Journal Of Agricultural Sciences
THE EFFICIENCY OF GUM-SILICA CMPOSITE FOR REMOVING OF WASTEWATER TURBIDITY
...Show More Authors

A novel mixed natural coagulant has been developed to remove sewage pollutants and heavy metals from Qanat- al- Jayesh by using low cost adsorbent natural materials. In these materials, significant interaction contains Arabic gum mixed with extracted silica from rice husk ash (natural coagulants) by the Batch device approach, using two variables, pH values ranging from 5-8 and contact times between 0.25-5 hrs. All wastewater samples were collected after treatment by adsorbents and examined for determination of residual heavy metal concentrations: Pb, Ni, Zn and Cu by atomic absorption spectroscopy (AAS), turbidity, pH, total dissolved salts (TDS), electrical conductivity (EC) and total salinity (TS). The results obtained indicate Th

... Show More
View Publication
Scopus (3)
Crossref (2)
Scopus Crossref