Preferred Language
Articles
/
1hYbEIcBVTCNdQwCETOX
Evaluating the Efficiency of some Wastewater Treatment Plants in Najaf Governorate
...Show More Authors
Abstract<p>Although there are many wastewater treatment plants, we still suffer from many problems resulting from a lack of experience or technical operating problems. In this research, the service’s efficiency is evaluated according to the design laws required for small factories in the province of Najaf, which works with filtering technology through point filtration, the old project in the Al-Baraka plant, and the second works. Within the biological treatment mbbr + activated sludge, which is a biomass technology where samples were taken from both plants and annual values of the pollutant rate after treatment in the old Al-Baraka plant project COD 64 mg/L and the demand for biochemical oxygen (79) mg/L, the total suspended matter TSS 60 mg / L, PO4 phosphate 2.67 mg / L, NH3 11.46 mg / L, while Turbo 4 BIO results were as follows: 15 mg / L and 28, 83 mg / L, 2.6 mg / L and 6.173 mg / L each who are they. BOD, COD, TSS, PO4, and NH3 respectively, the results were the removal efficiency of the old brake project as follows: BOD 78%, COD 60%, TSS 60, PO4 63% compared to the Bio-Shaft project, the removal is done as follows: BOD8 9%, TSS, COD 60% PO4 60%, NH3 53%. Through the previous results, we conclude that the outputs of both stations are within the standards and permissible limits of the Iraqi specifications, but the Turbo 4Bio plant showed higher efficiency in terms of removal, and the reason may be that the old project needs periodic maintenance.</p>
Crossref
View Publication
Publication Date
Wed Feb 01 2017
Journal Name
International Journal Of Science And Research (ijsr)
Performance Evaluation of the Organic Matter Removal Efficiency in Wastewater Treatment Plants; Case study Al- Diwaniyah WWTP in Iraq
...Show More Authors

This study aims to assess the removal efficiency andestablish the BOD5 and COD statisticalcorrelation of the sewage flowing in Al-Diwaniyah wastewater treatment plant in Iraq during the study period (2005-2016). The strength of the influent wastewater entering the plant varied from medium to high in strength. High concentrations of BOD5 and COD in the effluent were obtained due to the poor performance of the plant. This was observed from the BOD5 /COD ratios that did not confirm with the typical ratios for the treated sewage. To improve the performance of this plant, regression equations for BOD5 and COD removal percentages were suggested which can be used to facilitate evaluation of liquid waste and optimal control process. The equations

... Show More
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
pH-Control Problems of Wastewater Treatment Plants
...Show More Authors

Experimental investigations have been carried out to investigate the pH-control problems of industrial electroplating wastewater treatment plants. The accurate and sensitive PID control system could treat most problem and disturbances in the normal operation of the water treatment. However, conventional treatment was replaced by proprietary treatment agent called a QUASIL which was found to be more effective for a wide range of pH.

View Publication Preview PDF
Publication Date
Wed Jan 01 2014
Journal Name
Journal Of Water Resource And Protection
Evaluating Water Stability Indices from Water Treatment Plants in Baghdad City
...Show More Authors

View Publication
Crossref (25)
Crossref
Publication Date
Sun Feb 28 2021
Journal Name
Journal Of Economics And Administrative Sciences
Evaluating the Efficiency of the Municipal Sector in Anbar Governorate, using the Non-Parametric Approach (DEA).
...Show More Authors

 

The research aims to measure, assess and evaluate the efficiency of the directorates of Anbar Municipalities by using the Data Envelopment Analysis method (DEA). This is because the municipality sector is consider an important sector and has a direct contact with the citizen’s life. Provides essential services to citizens. The researcher used a case study method, and the sources of information collection based on data were monthly reports, the research population is represented by the Directorate of Anbar Municipalities, and the research sample consists of 7 municipalities which are different in terms of category and size of different types. The most important conclusion reached by the research i

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Journal Of Engineering
Performance Evaluation of Trickling Filter and Extended Aeration of Wastewater Treatment Plants
...Show More Authors

In recent decades, there has been increasing interest in wastewater treatment because of its direct impact on the environment and public health. Over time, other forms of treatment have been developed and modified, including extended aeration. This process is included in the suspended growth system. In this paper, a comparative study was conducted between the efficiency of the extended aeration plant and that of the trickling filter plant in removal of BOD and COD.  The method of comparison was done by knowing the value of the pollutant before and after the treatment and then extract the removal ratio of each pollutant within each plant. The results showed that the percentage of removal of BOD in the trickling filte

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Nov 01 2022
Journal Name
Environmental Research
Can electrocoagulation technology be integrated with wastewater treatment systems to improve treatment efficiency?
...Show More Authors

Considerable amounts of domestic and industrial wastewater that should be treated before reuse are discharged into the environment annually. Electrocoagulation is an electrochemical technology in which electrical current is conducted through electrodes, it is mainly used to remove several types of wastewater pollutants, such as dyes, toxic materials, oil content, chemical oxygen demand, and salinity, individually or in combination with other processes. Electrocoagulation technology used in hybrid systems along with other technologies for wastewater treatment are reviewed in this work, and the articles reviewed herein were published from 2018 to 2021. Electrocoagulation is widely employed in integrated systems with other electrochemical tech

... Show More
View Publication
Scopus (46)
Crossref (41)
Scopus Clarivate Crossref
Publication Date
Tue Sep 01 2020
Journal Name
Journal Of Engineering
Evaluating Electrocoagulation Process for Water Treatment Efficiency Using Response Surface Methodology
...Show More Authors

The electrocoagulation process became one of the most important technologies used for water treatment processes in the last few years. It’s the preferred method to remove suspended solids and heavy metals from water for treating drinking water and wastewater from textile, diary, and electroplating factories. This research aims to study the effect of using the electrocoagulation process with aluminum electrodes on the removal efficiency of suspended solids and turbidity presented in raw water and optimizing by the response surface methodology (RSM). The most important variables studied in this research included electrode spacing, the applied voltage, and the operating time of the electrocoagulation process. The samples

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Sep 12 2018
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Properties of Soil in Najaf Governorate
...Show More Authors

 Eight soil samples were selected around Najaf governorate at depth levels 40-50 cm. X-Ray Fluorescence (XRF) was used to determine the concentrations of major and trace elements. Liner and mass attenuation coefficient (µ, µρ) have been determined at gamma energies (662, 1172,1332) keV using NaI (Tl) detector. The range of linear attenuation coefficients for calculated samples were (0.553-1.163) cm-1, (0.122-0.178) cm-1 and (0.049-0.105) cm-1 at (662, 1172,1332) keV respectively. The range of mass attenuation coefficients obtained (0.39-0.76) cm2/gm, (0.087-0.117) cm2/gm and (0.0336-0.074) cm2/gm at (662, 1172,1332) keV respectively. The result

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Feb 01 2014
Journal Name
American University Of Sharjah (aus) "second International Conference On Sustainable Systems And The Environmental (isse14)
Correlating BOD5 and COD of Sewage in Wastewater Treatment Plants; Case study Al- Diwaniyah WWTP in Iraq
...Show More Authors

This study aims to establish an empirical correlation between biochemical oxygen demand (BOD5) and chemical oxygen demand (COD) of the sewage flowing in Al-Diwaniyah wastewater treatment plant. The strength of the wastewater entering the plant varied from medium to high. High concentrations of BOD5 and COD in the effluent were obtained due to the poor performance of the plant. This was observed from the BOD5 /COD ratios that did not confirm with the typical ratios for the treated sewage. To improve the performance of this plant, regression equations for BOD5 and COD removal percentages were suggested which can be used to facilitate rapid effluent assessment or optimal process control. The equations relating the percentage removal of

... Show More
Publication Date
Thu Mar 30 2023
Journal Name
Iraqi Journal Of Science
Petrography &Mineralogy of the Dammam Formation in Al-Najaf Governorate
...Show More Authors

The Dammam Formation ( Middle-Late Eocene) has a total thickness 150 m , 143 m and 89.7 m at the studied wells (B.H.8, B.H.3 and B.H.1) respectively. They are located in Al- Najaf Governorate, 35 Km southwest of Al-Najaf city. The petrographic components of the Dammam limestone comprises skeletal grainsforaminifera (both benthic and planktonic), echinoderm plates and Mollusca, shell fragments, Bryozoan, Bioclasts are common, non-skeletal grainsare pellets, lithoclast (carbonate and non carbonate), and groundmass (micrite and sparry calcite). In term of mineralogy, the X-Ray analysis shows the presence of non clay minerals is calcite, dolomite as the main minerals and quartz and scattered evaporate, whereas clay minerals as secondary mine

... Show More
View Publication