This work presents the simulation of a Low density Parity Check (LDPC) coding scheme with
multiuserMulti-Carrier Code Division Multiple Access (MC-CDMA) system over Additive White
Gaussian Noise (AWGN) channel and multipath fading channels. The decoding technique used in
the simulation was iterative decoding since it gives maximum efficiency with ten iterations.
Modulation schemes that used are Phase Shift Keying (BPSK, QPSK and 16 PSK), along with the
Orthogonal Frequency Division Multiplexing (OFDM). A 12 pilot carrier were used in the estimator
to compensate channel effect. The channel model used is Long Term Evolution (LTE) channel with
Technical Specification TS 25.101v2.10 and 5 MHz bandwidth including the channels of indoor
to outdoor/ pedestrian channel and Vehicular channel
The aim of this work is to study the effect of diesel fuel percentage on the combustion processes in compression ignition engine using dual – fuel (diesel and LPG).
The brake thermal efficiency increased with the increase of diesel fuel rate at low loads, and decreased when load increased. To get sufficient operation in engine fueled with dual fuel, it required sufficient flow rate of diesel fuel, if the engine fueled with insufficient diesel fuel erratic operation with miss fire cycles presented.
Dual-fuel operation at part load showed higher specific fuel consumption than straight diesl operation. At full loads, brake specific fuel consumption of duel fuel engine approaches that for diesel fuel values.
This study delves into the realm of advanced cooling techniques by examining the performance of a two-stage parallel flow indirect evaporative cooling system enhanced with aspen pads in the challenging climate of Baghdad. The objective was to achieve average air dry bulb temperatures (43 oC) below the ambient wet bulb temperatures (24.95 oC) with an average relative humidity of 23%, aiming for unparalleled cooling efficiency. The research experiment was carried out in the urban environment of Baghdad, characterized by high temperature conditions. The investigation focused on the potential of the two-stage parallel flow setup, combined with the cooling capability of aspen pads, to surpass the limitat
... Show MoreThe culture of theatre performance has a vital role in the process of reading the linguistic and visual signs of the performance. And the process of transforming a theatre performance from its original context into a new hosting cultural context starts from the actual reading of the text. Directors derives their new signs out of his personal culture, depending on the society where they lives and the culture that forms the social conventions, traditions and beliefs. The text is usually written within its own historical and temporal culture. The process of its production usually takes it away from its original culture, when it interprets the codes of the original writer and their visual and linguistic signs and instils new alternative sign
... Show MoreThis work presents the modeling of the electrical response of monocrystalline photovoltaic module by using five parameters model based on manufacture data-sheet of a solar module that measured in stander test conditions (STC) at radiation 1000W/m² and cell temperature 25 . The model takes into account the series and parallel (shunt) resistance of the module. This paper considers the details of Matlab modeling of the solar module by a developed Simulink model using the basic equations, the first approach was to estimate the parameters: photocurrent Iph, saturation current Is, shunt resistance Rsh, series resistance Rs, ideality factor A at stander test condition (STC) by an ite
... Show MoreAbstract
This research aims to evaluate the application of the inspectors general of global indicators offices according to the axles (leadership, strategy and planning, employees, partners and resources, process management) and through the assumption main research which states that (there is an application for global indicators to evaluate performance in the offices of the ministries under study) which are subdivided into five sub-hypotheses according to the classification and division of the five axes of the checklist.
The researchers have taken refuge in the process of assessing the performance of the check list which included global i
... Show MoreThe objective of the research is to determine the nature of the strategic direction of the institution and its impact on enhancing the indicators of institutional performance. The strategic direction is the main purpose for which it was found. Therefore, it is the main engine for all activities and tasks that the institution can carry out to achieve its objectives within the environment in which it operates. The promotion of corporate performance indicators is one of the major challenges that senior management must address in order to help the organization invest its human resources in the best possible way.
The research problem was determined by means of the intentional sample, consisting of (33) members
... Show MoreChilled ceilings systems offer potential for overall capital savings. The main aim of the present research is to investigate the thermal performance of the indirect contact closed circuit cooling tower, ICCCCT used with chilled ceiling, to gain a deeper knowledge in this important field of engineering which has been traditionally used in various industrial & HVAC systems. To achieve this study, experimental work were implemented for the ICCCCT use with chilled ceiling. In this study the thermal performances of closed wet cooling tower use with chilled ceiling is experimentally and theoretically investigated. Different experimental tests were conducted by varying the controlling parameters to investigate their effects
... Show MoreAn experimental study was carried out for an evaporative cooling system in order to investigate the effect of using an aluminum pad coated with fabric polyester. In the present work, it was considered to use a new different type of cooling medium and test its performance during the change in the wet-bulb temperature and dry-bulb temperature of the supply air outside of the pad, the relative humidity of the supply air, the amount of air supplied (300-600) CFM and also the change of the amount of circulated water (1.75, 2.5, 4.5) liter per minute. A decrease in the WBT of the air was obtained, whereas the WBT of the air entering the pad was 26.5 . In contrast, the WBT of the outside air had reached 23 even though eva
... Show MoreThis research aims to study the performance of operations to provide nursing services, which included dimensions (quality, timeliness, leadership skills, behavioral manifestations, relationships with others, problem-solving and decision-making, job performance) and its effects in nursing performance. The research to prove the value of the performance of service delivery processes dimensions by nursing staffs working in Iraqi hospitals, nursing and measuring performance. To find out the nature of nursing services, and a comparison between hospitals to measure the extent of the application dimensional among themselves, and that by relying on the dimensions of a global study, which was measu
... Show MoreThe theater has a living environment that resembles or realistically simulates the real life environment on the stage where we see the place, light and living being as elements representing a picture of the life scene and for a period of time the theater merely conveyed that image, but with the development of the world industrially and technologically, the perception of this picture has evolved with the emergence of intellectual progress where each part has advantages and Philosophical goals that are consistent with the evolution of form. The theatrical lighting, colors and landscapes have become parts in the composition of a new life component in form and content and based on the above this research is titled&nbs
... Show More