Preferred Language
Articles
/
joe-2976
Forward and Reverse Osmosis Process for Recovery and Re-use of Water from Polluted Water by Phenol
...Show More Authors

The research aims to apply the novel forward osmosis (FO) process to recover pure water
from contaminated water. Phenol was used as organic substance in the feed solution, while sodium
chloride salt was used as draw solution. Membranes used in the FO process is the cellulose
triacetate (CTA) and polyamide (thin film composite (TFC)) membrane. Reverse osmosis process
was used to treatment the draw solution, the exterior from the forward osmosis process. In the FO
process the active layer of the membrane faces the feed solution and the porous support layer faces
the draw solution and this will show the effect of dilutive internal concentration polarization and
concentrative external concentration polarization.
In the FO process was a run-time for five hours, and the concentration of phenol 100 and
1000 mg/l, and for the NaCl the concentration was 10000 and 30000 mg/l. It was found that
recovery percent increases with increasing time, while water flux through membrane decreases with
increasing time. Also, it was found that recovery and water flux increases with increasing draw
solution concentration, on the contrary, water flux and the percentage of recovery decreases with
increasing the concentration of phenol (feed solution). Increase in draw solute (NaCl) concentration
has more effect on the water flux in FO process compared with increase in the concentration of
phenol. Outlet phenol concentration increases with time, while the outlet salt concentration
decreases with increasing the time. The results showed that the cellulose triacetate membrane gave
the highest recovery ratio from the thin film composite membrane. The highest recovery was
reached in five hours is 51.33%, while using CTA membrane recovery rate increase, by 23%
compared with TFC membrane. The value of the resistance to solute diffusion within the membrane
porous support layer is 36.83 h/m. Reverse osmosis is perfect method for removal of dissolved salts
from water, thus its suitable process for reducing the content of NaCl in draw solution; therefore the
sodium chloride rejection percentage was 91.6 – 96 % for polyamide membrane (TFC). Within two
hours of work of the reverse osmosis system the recovery percentage of pure water is 58%.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Aug 07 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
The Equilibrium Isotherm Removal OF Chromium From Waste Water By Aquatic Plants Using Batch Process Adsorption
...Show More Authors

      This study was carried out in Baghdad (Al-Jadiriya) in 2006 by  detecting ability of aquatic reed plant to remove heavy metals (Chromium) from waste water by batch process of adsorption with considering that acidic solution is best selection for such process with constant initial chromium concentration(60 mg/l),speed of shaking(300 rpm), temperature (30 Co) and constant contact time (4 h) but with different weights of adsorbent (reed) (0.5 ,1 ,2 ,3 and 4 )gm for each 100 ml volume of sample .          The results showed that the percentage of the removed chromium were ( 8% ,17.5% ,31% ,40% and 50%) respectively for each sample according to the mass of adsorb

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Aip Conf. Proc.
Removal of chromium ions from a real wastewater of leather industry using electrocoagulation and reverse osmosis processes
...Show More Authors

This study focused on treatment of real wastewater rejected from leather industry in Al-Nahrawan city in Iraq by Electrocoagulation (EC) process followed by Reverse Osmosis (RO) process. The successive treatment was applied due to high concentration of Cr3+ ions (about 1600 ppm) rejected in wastewater of this industry and for applying EC with moderate power consumption and better results of produced water. In Electrocoagulation process (EC), the effect of NaCl concentration (1.5, 3 g/l), current density (C.D.) (15-25 mA/cm2), electrolysis time (1-2 h), and distance between electrodes (E.D.) (1-2 cm) were examined in a batch cell by implementing Taguchi experimental design. According to the results obtained from multiple regression and signa

... Show More
View Publication Preview PDF
Scopus (18)
Crossref (14)
Scopus Crossref
Publication Date
Thu Sep 05 2019
Journal Name
Journal Of Engineering / University Of Baghdad
Subsurface Water Retention a Technology for Increasing the Field Use Efficiency and Water Saving Values of Cucumber Plant
...Show More Authors

The technology of subsurface soil water retention (SWRT) uses a polyethylene trough that is fixed under the root zone of the plant. It is a modern technology to increase the values of water use efficiency, plant productivity and saving irrigation water by applying as little irrigation water as possible. This study work aims at improving the crop yield and water use efficiency of a cucumber plant with less applied irrigation water by installing membrane trough below the soil surface. The field experiment was conducted in the Hawr Rajab District of Baghdad Governorate in Winter 2018 for testing various trickle irrigation systems. Two agricultural treatment plots were utilized in a greenhouse for the comparison. Plot T1 has used a subsurface t

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Wed Aug 28 2019
Journal Name
Journal Of Engineering
Subsurface Water Retention a Technology for Increasing the Field Use Efficiency and Water Saving Values of Cucumber Plant
...Show More Authors

The technology of subsurface soil water retention (SWRT) uses a polyethylene ‎trough that is fixed under the root zone of the plant. It is a modern technology to increase the values of water ‎use efficiency, plant productivity and saving irrigation water by applying as little irrigation water ‎as possible. This study work aims at improving the crop yield and water use efficiency of a cucumber plant with less applied irrigation water by installing membrane trough below the soil surface. The field experiment was conducted in the Hawr Rajab District of ‎Baghdad Governorate in Winter 2018 for testing various trickle irrigation ‎systems. Two agricultural ‎treatment plots were utilized in a greenhouse for the compa

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
study the effects of the polluted waste water on the environment
...Show More Authors

to study the discribrion and the pollution in the environment in the south of baghdad samples of waste water from industrail units using the mercury in its process also

View Publication Preview PDF
Publication Date
Wed Sep 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A Study of Forward Osmosis Using Various Drawing Agent
...Show More Authors

This research was aimed to study the osmotic efficiency of the draw solutions and the factors affecting the performance of forward osmosis process : The draw solutions used were magnesium sulfate hydrate (MgSO4.7H2O) pojtassium chloride (KCL), calcium chloride (CaCl2) and ammonium bicarbonate (NH4HCO3). It was found that water flux increases with increasing draw solution concentration, and feed solution flow rate and decreases with increasing draw solution flow rate and feed solution concentration. And also found that the efficiency of the draw solutions is in the following order:

CaCl2> KCI > NH4HCO3> MgSO4.7H

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 01 2023
Journal Name
Iraqi Journal Of Physics
Polluted Water Sensor Based on Carbon Quantum Dots/Alq3 Using Drop Casting and Spin Coating Techniques
...Show More Authors

Water quality sensors have recently received a lot of attention due to their impact on human health. Due to their distinct features, environmental sensors are based on carbon quantum dots (CQDs). In this study, CQDs were prepared using the electro-chemical method, where the structural and optical properties were studied. These quantum dots were used in the environmental sensor application after mixing them with three different materials: CQDs, Alq3 polymer and CQDs and Alq3 solutions using two different methods: drop casting and spin coating, and depositing them on silicon. The sensitivity of the water pollutants was studied for each case of the prepared samples after measuring the change in resistance of the samples at a temperature of

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jan 30 2020
Journal Name
Journal Of Engineering
Advanced Oxidation of Antibiotics Polluted Water Using Titanium Dioxide in Solar Photocatalysis Reactor
...Show More Authors

The aim of this study was to investigate antibiotic amoxicillin removal from syn­thetic pharmaceutical wastewater. Titanium dioxide (TiO2) was used in photocatalysis treatment method under natural solar irradiation in a tubular reactor. The photocatalytic removal efficiency was evaluated by the reduction in amoxicillin concentration. The effects of antibiotics concentration, TiO2 dose, irradiation time and the effect of pH were studied. The optimum conditions were found to be irradiation time 5 hr, catalyst dosage 0.6 g/L, flow rate 1 L/min and pH 5. The photocatalytic treatment was able to destruct the amoxicillin in 5 hr and induced an amoxicillin reduction of about 10% with 141.8 kJ/L accumulate

... Show More
View Publication Preview PDF
Crossref (10)
Crossref
Publication Date
Wed Jun 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Emulsified Kerosene from Water by Flotation
...Show More Authors

View Publication Preview PDF
Publication Date
Tue Jun 30 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Furfural Degradation in Waste Water by Advanced Oxidation Process Using UV/H2O2
...Show More Authors

Furfural is one of the one of pollutants in refinery industrial wastewaters. In this study advanced oxidation process using UV/H2O2 was investigated for furfural degradation in synthetic wastewater. The results from the experimental work showed that the degradation of furfural decreases as its concentration increases, reaching 100% at 50mg/l furfural concentration and increasing the concentration of H2O2 from 250 to 500 mg/l increased furfural removal from 40 to 60%.The degradation of furfural reached 100% after 90 min exposure time using two UV lamps, where it reached 60% using one lamp after 240 min exposure time. The rate of furfural degradation k increased at the pH and initial concentratio

... Show More
View Publication Preview PDF