Preferred Language
Articles
/
joe-276
Thermal Characteristics of Closed Wet Cooling Tower Using Different Heat Exchanger Tubes Arrangement
...Show More Authors

This paper presents thermal characteristics analysis of a modified Closed Wet Cooling Tower (CWCT) based on heat and mass transfer principles to improve the performance of this tower in Iraq. A prototype of CWCT optimized by added packing was designed, manufactured and tested for cooling capacity of 9 kW. Experiments are conducted to explore the effects of various operational and conformational parameters on the thermal performance. In the test section, spray water temperature and both dry bulb temperature and relative humidity of the air measured at intermediate points of the heat exchanger and packing. Heat exchangers consist of four rows and eight columns for an inline tubes arrangement and six rows and five columns for staggered tubes arrangement. According to experimental data, the inline tubes arrangement has a better thermal performance than the staggered tubes arrangement. The inline tubes arrangement enhanced thermal efficiency more than (7%) compared to the staggered tubes arrangement. Furthermore the effect of added packing to CWCT on thermal performance was significant compared to CWCT without packing. Comparing CWCT with packing, it has been observed that the best performance for the CWCT with packing under heat exchanger. It can be watched that the thermal efficiency for CWCT with packing under heat exchanger and CWCT with packing above heat exchanger approximately (28%) and (16%) higher than that CWCT without packing respectively. This study provides correlations to predict heat and mass transfer considering the influences of operational parameters for both inline and staggered heat exchanger tubes arrangement.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 01 2020
Journal Name
Iraqi Journal Of Physics
Enhancement of thermal stability and wettability for epoxy/Cu coated carbon fiber composites
...Show More Authors

    This research study the effect of surface modification and copper (Cu) plating carbon fiber (CF) surface on the thermal stability and wettability of carbon fiber (CF)/epoxy (EP) composites. The TGA result indicates that the thermal-stability of carbon fiber may be enhanced after Cu coating CF. TGA curve showed that the treatment temperature was enhanced thermal stability of Ep/CF, this is due to the oxidation during heating. The Cu plating increased the thermal conductivity, this increase might be due to reduce in contact resistance at the interface due to chemical modification and copper plating and tunneling resistance.

   The increase of surface polarity after coating cause decreas

... Show More
View Publication Preview PDF
Crossref (9)
Crossref
Publication Date
Thu Sep 01 2016
Journal Name
Applied Thermal Engineering
Solidification of a PCM with nanoparticles in triplex-tube thermal energy storage system
...Show More Authors

Crossref (171)
Crossref
Publication Date
Mon Sep 01 2025
Journal Name
Al-khwarizmi Engineering Journal
Impact of Design Parameters in Thermal Solar Water Storage Tank Systems: (A Review)
...Show More Authors

This work provides a historical overview of water storage tanks used for solar energy collection, with a focus on the impact of different geometric configurations on thermal performance and energy storage efficiency. The designs of cylindrical, spherical, rectangular and triangular tanks were reviewed to analyse their effects on thermal gradients, heat retention and energy storage capacity. Within the scope of nominal processes, the study primarily aimed to identify the factors influencing the choice of tank shape in terms of size, capacity and aspect ratio. Another key objective was to assess what enhances heat storage in the tank to improve thermal efficiency. Comparing cylindrical shapes to other shapes, such as spherical, rectan

... Show More
View Publication
Scopus Crossref
Publication Date
Fri Jan 01 2010
Journal Name
Advances In Condensed Matter Physics
Electrical and Optical Properties of :H Thin Films Prepared by Thermal Evaporation Method
...Show More Authors

Thin a-:H films were grown successfully by fabrication of designated ingot followed by evaporation onto glass slides. A range of growth conditions, Ge contents, dopant concentration (Al and As), and substrate temperature, were employed. Stoichiometry of the thin films composition was confirmed using standard surface techniques. The structure of all films was amorphous. Film composition and deposition parameters were investigated for their bearing on film electrical and optical properties. More than one transport mechanism is indicated. It was observed that increasing substrate temperature, Ge contents, and dopant concentration lead to a decrease in the optical energy gap of those films. The role of the deposition conditions on value

... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Thu Jun 02 2016
Journal Name
Ashrae Transactions
Melting of PCM with nanoparticles in a triplex-tube thermal energy storage system
...Show More Authors

Scopus (30)
Scopus
Publication Date
Wed May 29 2019
Journal Name
Iraqi Journal Of Physics
Weathering effects on the thermal conductivity of PS/PMMA blends for packaging application
...Show More Authors

This work describes the weathering effects (UV-Irradiation, and Rain) on the thermal conductivity of PS, PMMA, PS/PMMA blend for packaging application. The samples were prepared by cast method at different ratios (10, 30, 50, 70, and 90 %wt). It was seen that the thermal conductivity of PMMA (0.145 W/m.K), and for PS(0.095 W/m.K), which increases by PS ratio increase up to 50% PS/PMMA blend then decreased that was attributed to increase in miscibility of the blend involved. By UV-weathering, it was seen that thermal conductivity for PMMA increased with UV-weathering up to (30hr) then decreased, that was attributed to rigidity and defect formation, respectively. For 30%PS/PMMA, there results showed unsystematic decrease in thermal conduct

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue May 01 2018
Journal Name
Journal Of Physics: Conference Series
The Effects of micro Aluminum fillers In Epoxy resin on the thermal conductivity
...Show More Authors

View Publication
Scopus (37)
Crossref (24)
Scopus Clarivate Crossref
Publication Date
Thu Sep 01 2016
Journal Name
Applied Thermal Engineering
Solidification of a PCM with nanoparticles in triplex-tube thermal energy storage system
...Show More Authors

View Publication
Scopus (171)
Crossref (171)
Scopus Clarivate Crossref
Publication Date
Tue Sep 01 2015
Journal Name
2015 Ieee International Circuits And Systems Symposium (icsys)
Investigating the impact of on-chip interconnection noise on Dynamic Thermal Management efficiency
...Show More Authors

Dynamic Thermal Management (DTM) emerged as a solution to address the reliability challenges with thermal hotspots and unbalanced temperatures. DTM efficiency is highly affected by the accuracy of the temperature information presented to the DTM manager. This work aims to investigate the effect of inaccuracy caused by the deep sub-micron (DSM) noise during the transmission of temperature information to the manager on DTM efficiency. A simulation framework has been developed and results show up to 38% DTM performance degradation and 18% unattended cycles in emergency temperature under DSM noise. The finding highlights the importance of further research in providing reliable on-chip data transmission in DTM application.

View Publication
Scopus (2)
Scopus Crossref
Publication Date
Tue Sep 01 2015
Journal Name
Journal Of Engineering
Mixed Convection Heat Transfer in a Vertical Saturated Concentric Annulus Packed with a Metallic Porous Media
...Show More Authors

Mixed convection heat transfer in a vertical concentric annulus packed with a metallic porous media and heated at a constant heat flux is experimentally investigated with water as the working fluid. A series of experiments have been carried out with a Rayleigh number range from Ra=122418.92 to 372579.31 and Reynolds number that based on the particles diameter of Red=14.62, 19.48 and 24.36. Under steady state condition, the measured data were collected and analyzed. Results show that the wall surface temperatures are affected by the imposed heat flux variation and Reynolds number variation. The variation of the local heat transfer coefficient and the mean Nusselt number are presented and analyzed. An empirical

... Show More
View Publication Preview PDF