Removal of Nickel and Cadmium Ions from Wastewater by Sorptive Flotation: Single and Binary systems
...Show More Authors

The removal of heavy metal ions from wastewater by sorptive flotation using Amberlite IR120 as a resin, and flotation column, was investigated. A combined two-stage process is proposed as an alternative of the heavy metals removal from aqueous solutions. The first stage is the sorption of heavy metals onto Amberlite IR120 followed by dispersed-air flotation. The sorption of metal ions on the resin, depending on contact time, pH, resin dosage, and initial metal concentration was studied in batch method .Various parameters such as pH, air flow rate, and surfactant concentration were investigated in the flotation stage. Sodium lauryl sulfate (SLS) and Hexadecyltrimethyl ammonium bromide (HTAB) were used as anionic and cationic surfactant respectively. The sorption process, which is PH dependent, shows maximum removal of metal ions at pH 7. Langmuir and Freundlich isotherm expressions were found to give both a good fit to the experimental data. Kinetic data correlated well with Lagergren second order kinetic model, and flotation step enhanced the removal efficiency of nickel and cadmium from wastewater from about 75% to 94% and reduce turbidity so it can dispense with the filtering process, which is expensive technology. It is believed that flotation separation has great potential as a clean water and wastewater treatment technology.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Feb 12 2019
Journal Name
Iraqi Journal Of Laser
Generation of True Random TTL Signals for Quantum Key-Distribution Systems Based on True Random Binary Sequences
...Show More Authors

A true random TTL pulse generator was implemented and investigated for quantum key distribution systems. The random TTL signals are generated by low cost components available in the local markets. The TTL signals are obtained by using true random binary sequences based on registering photon arrival time difference registered in coincidence windows between two single – photon detectors. The true random TTL pulse generator performance was tested by using time to digital converters which gives accurate readings for photon arrival time. The proposed true random pulse TTL generator can be used in any quantum -key distribution system for random operation of the transmitters for these systems

View Publication Preview PDF
Publication Date
Wed Jul 01 2020
Journal Name
Chemical Engineering Research And Design
Simultaneous studies of emulsion stability and extraction capacity for the removal of tetracycline from aqueous solution by liquid surfactant membrane
...Show More Authors

View Publication
Scopus (45)
Crossref (41)
Scopus Clarivate Crossref
Publication Date
Mon Mar 11 2019
Journal Name
Baghdad Science Journal
Laboratory Study for Biodegradation of Oxymatrine Insecticide by Single and Mixed Cultures of Fungi Isolated from Agriculture Soils in Basrah Governorate, Iraq
...Show More Authors

This study focuses on the biodegradation of oxymatrine insecticide by some soil fungi isolated from four agriculture stations. The results showed that the highest degradation rate 94.66% was recorded by Ulocladium sp. at 10 days and A. niger recorded the lowest degradation rate 45.86%, while at 20 days Ulocladium sp. also showed the highest degradation rate 94.98% and the lowest degradation rate reached to 82.49% with A.niger. The mix (Exerohilum sp.+Ulocladium sp.) recorded the highest degradation rate of oxymatrine insecticide 90.22%, 88.51%, 85.34%  at 4, 8 and 12 ppm.The use of mixed isolates enhanced the biodegradation process. There is no study of oxymatrine biodegradation

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Jul 30 2019
Journal Name
Sn Applied Sciences
Removal of oil emulsion from aqueous solution by using Ricinus communis leaves as adsorbent
...Show More Authors

View Publication
Scopus (10)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Thu Feb 25 2021
Journal Name
Iraqi Journal Of Agricultural Sciences
OPTIMIZATION OF LEVOFLOXACIN REMOVAL FROM AQUEOUS SOLUTION USING ELECTROCOAGULATION PROCESS BY RESPONSE SURFACE METHODOLOGY
...Show More Authors

This study was aimed to investigate the response surface methodology (RSM) to evaluate the effects of various experimental conditions on the removal of levofloxacin (LVX) from the aqueous solution by means of electrocoagulation (EC) technique with stainless steel electrodes. The EC process was achieved successfully with the efficiency of LVX removal of 90%. The results obtained from the regression analysis, showed that the data of experiential are better fitted to the polynomial model of second-order with the predicted correlation coefficient (pred. R2) of 0.723, adjusted correlation coefficient (Adj. R2) of 0.907 and correlation coefficient values (R2) of 0.952. This shows that the predicted models and experimental values are in go

... Show More
Crossref (15)
Crossref
Publication Date
Tue Sep 27 2016
Journal Name
Mine Water Environ.
Dominant Mechanisms for Metal Removal from Acidic Aqueous Solutions by Cement Kiln Dust
...Show More Authors

Scopus (6)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Tue Jan 09 2018
Journal Name
World Rural Observations
Solid cartridges in Determination of Benzidines in River and Wastewater by HPLC
...Show More Authors

A solid Phase Extraction (SPE) cartridges followed by HPLC-UV method is described for the simultaneous quantitative determination of benzidine (BZ) and its substituted 3, 3’-dichlorobenzidine (DCB) and 3, 3’-Dimethylbenzidine (DMB). The Benzidines were separated by liquid chromatography using a C-18 column with UV detector at wave length of 280nm. The mode of Flow was isocratic. The mobile phase was consisted of 75:25 methanol: water, column temperature 50C°, and Flow Rate 1.8ml/min. Calibration curves were linear (R2 = 0.9979-0.9995). LOD (26.36-33.67) µg/L, LOQ (109.98-186.11) µg/L, the Robustness (2.99-4.35), Ruggedness (2.93-3.65).Conditions of extraction by (SPE) cartridges were optimized, the resin used is Octadecyl silica (ODS

... Show More
Publication Date
Wed Jun 29 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Kinetics and Energetic Parameters Study of Phenol Removal from Aqueous Solution by Electro-Fenton Advanced Oxidation Using Modified Electrodes with PbO2 and Graphene
...Show More Authors

The Electro-Fenton oxidation process is one of the essential advanced electrochemical oxidation processes used to treat Phenol and its derivatives in wastewater. The Electro-Fenton oxidation process was carried out at an ambient temperature at different current density (2, 4, 6, 8 mA/cm2) for up to 6 h. Sodium Sulfate at a concentration of 0.05M was used as a supporting electrolyte, and 0.4 mM of Ferrous ion concentration (Fe2+) was used as a catalyst. The electrolyte cell consists of graphite modified by an electrodepositing layer of PbO2 on its surface as anode and carbon fiber modified with Graphene as a cathode. The results indicated that Phenol concentration decreases with an increase in current dens

... Show More
View Publication Preview PDF
Crossref (11)
Crossref
Publication Date
Mon Jul 10 2023
Journal Name
Journal Of Engineering
Removal of Water Turbidity by Different Coagulants
...Show More Authors

During the last decade, there has been a concern about the relation between aluminum residuals in treated water and Alzheimer disease, and more interest has been considered on the development of natural coagulants. The present study aimed to investigate the efficiency of alum as a primary coagulant in conjunction with mallow, Arabic gum and okra as coagulant aids for the treatment of water samples containing synthetic turbidity of kaolin. Jar test experiments were carried out for initial raw water turbidities 100, 200 and 500 (NTU). The optimum doses of alum, mallow, Arabic gum and okra were 20, 2, 1 and 1 mg/L for100 NTU turbidity level, 35, 4, 2 and 3 mg/L , for 200NTU turbidity level and 50, 8, 10 and 8 mg/L for 500 NTU turbidity leve

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Spectral studies of Nickel(II) and Chromium(III)
...Show More Authors

Complexes of Cr(III)andNi(II) ions with phthalate sulphanilate snthranillate hippurte and glycinate ions have been preparcd then the Nephelauxetic