This study investigates the performance of granular dead anaerobic sludge (GDAS) bio-sorbent as permeable reactive barrier in removing phenol from a simulated contaminated shallow groundwater. Batch tests have been performed to characterize the equilibrium sorption properties of the GDAS and sandy soil in phenol-containing aqueous solutions. The results of GDAS tests proved that the best values of operating parameters, which achieve the maximum removal efficiency of phenol (=85%), at equilibrium contact time (=3 hr), initial pH of the solution (=5), initial phenol concentration (=50 mg/l), GDAS dosage (=0.5 g/100 ml), and agitation speed (=250 rpm). Fourier transform infrared (FTIR) analysis proved that the carboxylic acid, aromatic, alkane, alcohol, and alkyl halides groups are responsible for the bio-sorption of phenol onto GDAS.
A 2D advection-dispersion, solved numerically by computer solutions (COMSOL) Multiphysics 3.5a software which is based on the finite element method, has been used to simulate the equilibrium transport of phenol within groundwater. This model is taking into account the pollutant sorption onto the GDAS and sandy soil which is represented by Langmuir equation. Numerical and experimental results proved that the barrier plays a potential role in the restriction of the contaminant plume migration. Also, the barrier starts to saturate with contaminant as a function of the travel time. A good agreement between the predicted and experimental results was recognized with root mean squared error not exceeded the 0.055.
During 2019-2020, the experiment was conducted in the laboratory of the Department of Field Crop Sciences, Faculty of Agricultural Engineering Sciences - Baghdad University, to investigate the impact of soaking wheat seeds produced during the 2016 agricultural season with three plant extracts (licorice root extract 2%, 4% and 6%, Acadian and Humic(500, 1000, & 1500 mg L-1). Aside from the two control treatments (soaking in distilled water with dried seeds). The results show that the soaking treatment with licorice root extract outperformed the other therapies in conventional laboratory germination, root length, and seedling vigor index (95 percent and 3.42 cm 1207) compared to the two control treatments (soaking with distilled w
... Show MoreThis study aims to evaluate drinking water quality at the Al Wahda plant (WTP) in Baghdad city. A conventional water treatment plant with an average flow rate of 72.82 MLD. Water samples were taken from the influent and effluent of the treatment plant and analyzed for some physicochemical and biological parameters during the period from June to November 2020. The results of the evaluation indicate that treated water has almost the same characteristics as raw water; in other terms, the plant units do not remove pollutants as efficiently as intended. Based on this, the station appears to be nothing more than a series of water passage units. However, apart from Total dissolved solids, the mean values of all parameters in the study were
... Show MoreThis study aims to evaluate drinking water quality at the Al Wahda plant (WTP) in Baghdad city. A conventional water treatment plant with an average flow rate of 72.82 MLD. Water samples were taken from the influent and effluent of the treatment plant and analyzed for some physicochemical and biological parameters during the period from June to November 2020. The results of the evaluation indicate that treated water has almost the same characteristics as raw water; in other terms, the plant units do not remove pollutants as efficiently as intended. Based on this, the station appears to be nothing more than a series of water passage units. However, apart from Total dissolved solids, the mean values of all parameters in th
... Show MoreSixteen water samples were collected from the operation units of the Al-Quds
power plant, north Baghdad city and the surrounding trocars, surface and
groundwater, and analyzed to assess the resulting pollution. The samples were
analyzed for heavy metals (As, Cd, Cr, Cu, Mn, Mo, Ni, Pb, Sb, Se, U and Zn) by
using inductively coupled plasma- mass spectrometry (ICP-MS). The results were
compared with local and international and standard limits. Heavy metals analysis of
the water samples shows that water of operation units and trocars have mean
concentrations of As, Cd, Cr, Cu, Mo, Pb, Sb, Se, U and Zn were within or lower
than the national and world limits, while Mn and Ni were higher than these limits.
Concentrat
The concrete need curing for cement hydration that is a chemical reaction in each step require water supply throughout the time period. The traditional concrete cured by external method that prevents the concrete surface dry so that keeping the concrete mixture wet and warm. The internal curing was adopted in normal and high strength concrete such as reactive powder concrete. In present paper, experimental approach is to study the mechanical properties of reactive powder concrete cured internally with thermostone material. The materials that adopted to evaluate and find out the influences of the internal curing on the mechanical properties of reactive powder concrete is focused with d
Non-biodegradability of rubber tires contributes to pollution and fire hazards in the natural environment. In this study, the flexural behavior of the Rubberized Reactive Powder Concrete (RRPC) beams that contained various proportions and sizes of scrap tire rubber was investigated and compared to the flexural behavior of the regular RPC. Fresh properties, hardened properties, load-deflection relation, first crack load, ultimate load, and crack width are studied and analyzed. Mixes were made using micro steel fiber of the straight type, and they had an aspect ratio of 65. Thirteen beams were tested under two loading points (Repeated loading) with small-scale beams (1100 mm, 150 mm, 100 mm) size.
The fine aggregate
... Show MoreThe present study aims to evaluate the biosorption of reactive orange dye by using garden grass. Experiments were carried out in a batch reactor to obtain equilibrium and thermodynamic data. Experimental parameters affecting the biosorption process such as pH, shaking time, initial dye concentrations, and temperature were thoroughly examined. The optimum pH for removal was found to be 4. Fourier transform infrared spectroscopy analysis indicated that the electronegative groups on the surface of garden grass were the major groups responsible for the biosorption process. Four sorption isotherm models were employed to analyze the experimental data of which Temkin and Pyzhey model was found to be most suitable one. The maxim
... Show More